HomeMy WebLinkAbout2415 Palomino Dr - Disclosures/Final Energy - 11/11/2016Air Leakage
Property
DR Horton Homeowner
2415 Palomino Dr
Ft Collins, CO 80525
Weather:Ft. Collins, CO
DR Horton
2415 Palomino Dr DR Horton REM
14.6.4.big
Whole House Infiltration
Duct Leakage
Ventilation
Organization
EnergyLogic, Inc
(970)556-0839
Neal Girard
Builder
DR Horton
Natural ACH
ACH @ 50 Pascals
CFM @ 25 Pascals
CFM @ 50 Pascals
Eff. Leakage Area (sq.in)
Specific Leakage Area
ELA/100 sf shell (sq.in)
Leakage to Outside Units
CFM @ 25 Pascals
CFM25 / CFMfan
CFM25 / CFA
CFM per Std 152
CFM per Std 152 / CFA
CFM @ 50 Pascals
Eff. Leakage Area (sq.in)
Thermal Efficiency
Total Duct Leakage Units
Total Duct Leakage
Mechanical
Sensible Recovery Eff. (%)
Total Recovery Eff. (%)
Rate (cfm)
Hours/Day
Fan Watts
Cooling Ventilation
HERS
Confirmed
11/11/16
Rating No:42960
RaterID:4606190
Blower Door Test
Heating I Cooling
0.13
2.15
1469
2305
126.5
0.00014
1.14
Main
0
0.0000
0.0000
N/A
N/A
0
0.00
N/A
CFM25/CFA
0.0185
Exhaust Only
0.0
0.0
108
24.0
30.0
No Ventilation
0.10
2.15
1469
2305
126.5
0.00014
1.14
Upper
68
0.0560
0.0270
N/A
N/A
107
5.86
N/A
CFM25/CFA
0.0349
ASHRAE
62.2-2010
108
24.0
ASHRAE 62.2 - Ventilation Requirements
energyLogic
anal Y.l.. In.lyhl. an...i..
The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole -building'
requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent
mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours
per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to
the appropriate standard.
REM/Rate - Residential Energy Analysis and Rating Software v14.6.4
This information does not constitute any warranty of energy cost or savings.
O 1985-2016 Noresco, Boulder, Colorado.
2012 IECC Energy Cost Compliance
Property
Organization
DR Horton Homeowner
EnergyLogic, Inc
2415 Palomino Dr
(970) 556-0839
Ft Collins, CO 80525
Neal Girard
Weather:Ft. Collins, CO Builder
DR Horton DR Horton
2415 Palomino Dr DR Horton REM
Annual Energy Cost
HERS
Confirmed
11/11/16
Rating No:42960
RaterID:4606190
energyLogic
...... i.. inaom. an......
$/yr
2012 IECC As Designed
Heating
761 ...692
Cooling
286 _
197
Water Heating ..
174
175
SubTotal - Used to Determine Compliance
- 1220
10641
Lights Ft Appliances
1230•
1214
Photovoltaics
=0
-0
Service Charge-
y
240
240
Total
2690
25181
Mandatory Reauirements
Annual Energy Cost Check
PASSES a
Duct Insulation R-Value Check (per Section 405.2)
PASSES j
Window U-Value and SHGCtheck: (per Section 402.5)
PASSEStl
Home Infiltration (Section 402.4.1.2) -
`PASSES
Duct Leakage (Section 403d:2) -
PASSES
Mechanical Ventilation (Section 403.6)
PASSES
Mechanical Ventilation-FanEfficacy (Section°403r5.1)
i=PASSES
Mandatory Requirements Check Box (2012 IECC) - ',
'PASSES
This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code
based on a climate zone of 5B. In fact, this home surpasses the requirements by 12XovemZber2016
8%
Name Neal Girard Signature
Organization EnergyLogic, Inc Date 11
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate - Residential Energy Analysis and Rating Software v14.6.4
This information does not constitute any warranty of energy cost or savings.
m 1985.2016 Noresco, Boulder, Colorado.
2012 IECC Certificate
2415 Palomino Dr, Ft Collins, CO 80525
Building Envelope Insulation
Ceiling R-38.0
Above Grade Walls R-21.0
Foundation Walls R-19.0
Exposed Floor R-38.0
Slab R-0.0 Edge, R-0.0 Under
Infiltration Htg: 2305 Clg: 2305 CFM50
Duct Uninsulated
Total Duct Leakage 70.00 CFM ® 25 Pascals
Window Data U-Factor w _ SHGC w
Window 0.310 0.360
Mechanical Equipment
HEAT: Fuel -fired air distribution, Natural gas, 92.1 AFUE.
COOL: Air conditioner, Electric, 13.0 SEER.
DHW: Conventional, Natural gas, 0.59 EF, 50.0 Gal.
Builder or Design Professional_m
Signature
REM/Rate - Residential Energy Analysis and Rating Software
v14.6.4
Property
DR Horton
DR Horton Homeowner
2415 Palomino Dr
Ft Collins, CO 80525
Energy
Rating •
HERS
Rating Type: Confirmed
Rating Date: 11/11/16
Registry ID: 832392001
Certified Energy Rater: Neal Girard
Rating Number:
HERS Index: 55
General Information
Conditioned Area 6311 sq. ft. House Type Single-family detached
Conditioned Volume 64389 cubic ft. Foundation Conditioned basement
Bedrooms 5
Mechanical Systems Features
Water Heating: Conventional, Natural gas, 0.59 EF, 50.0 Gal.
Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE.
Cooling: Air conditioner, Electric, 13.0 SEER.
Duct Leakage to Outside 68.00 CFM25.
Ventilation System Exhaust Only: 108 cfm, 30.0 watts.
Programmable Thermostat Heat=Yes; Cool=Yes
Building Shell Features
Ceiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 Under
Sealed Attic NA Exposed Floor R-38.0
Vaulted Ceiling
NA
Window Type
U-Value: 0.310, SHGC: 0.360
Above Grade Walls
R-21.0
Infiltration Rate
Htg: 2305 Clg: 2305 CFM50
Foundation Walls
R-19.0
Method
Blower door test
Lights and Appliance Features
Percent Interior Lighting 100.00
Range/Oven Fuel
Natural gas
Percent Garage Lighting 100.00
Clothes Dryer Fuel
Electric
Refrigerator (kWh/yr) 1257
Clothes Dryer EF
2.67
Dishwasher (kWh/yr) 270
Ceiling Fan (cfm/Watt)
0.00
el
42960
energyLogic
an n l v. I.. In.lyl. un......
Estimated Annual Energy Cost
Use
MMBtu
Cost
Percent
Heating
55.2
$652
27%
Cooling
9.7
$99
4%
Hot Water
16.6
$176
7%
Lights/Appliances
44.2
$1214
51%
Photovoltaics
-0.0
$.0
-0%
Service Charges
$240
10%
Total
125.6
$2381
100%-
Criteria
This home meets or exceeds the minimum criteria for the following:
2012 International Energy Conservation Code
Home Energy Rating Provider
EnergyLogic, Inc.
P.O. Box N
Berthoud, CO 80513
Phone k 1-800-315-0459
www.nrgLogic.com
Certified Energy Rater:
REM/Rate - Residential Energy Analysis and Rating Software v14.6.4
This information does not constitute any warranty of energy cost or savings. O 1985-2016 Noresco, Boulder, Colorado.
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.