HomeMy WebLinkAbout2415 Palomino Dr - Disclosures/Final Energy - 11/11/2016Air Leakage Property DR Horton Homeowner 2415 Palomino Dr Ft Collins, CO 80525 Weather:Ft. Collins, CO DR Horton 2415 Palomino Dr DR Horton REM 14.6.4.big Whole House Infiltration Duct Leakage Ventilation Organization EnergyLogic, Inc (970)556-0839 Neal Girard Builder DR Horton Natural ACH ACH @ 50 Pascals CFM @ 25 Pascals CFM @ 50 Pascals Eff. Leakage Area (sq.in) Specific Leakage Area ELA/100 sf shell (sq.in) Leakage to Outside Units CFM @ 25 Pascals CFM25 / CFMfan CFM25 / CFA CFM per Std 152 CFM per Std 152 / CFA CFM @ 50 Pascals Eff. Leakage Area (sq.in) Thermal Efficiency Total Duct Leakage Units Total Duct Leakage Mechanical Sensible Recovery Eff. (%) Total Recovery Eff. (%) Rate (cfm) Hours/Day Fan Watts Cooling Ventilation HERS Confirmed 11/11/16 Rating No:42960 RaterID:4606190 Blower Door Test Heating I Cooling 0.13 2.15 1469 2305 126.5 0.00014 1.14 Main 0 0.0000 0.0000 N/A N/A 0 0.00 N/A CFM25/CFA 0.0185 Exhaust Only 0.0 0.0 108 24.0 30.0 No Ventilation 0.10 2.15 1469 2305 126.5 0.00014 1.14 Upper 68 0.0560 0.0270 N/A N/A 107 5.86 N/A CFM25/CFA 0.0349 ASHRAE 62.2-2010 108 24.0 ASHRAE 62.2 - Ventilation Requirements energyLogic anal Y.l.. In.lyhl. an...i.. The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole -building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. O 1985-2016 Noresco, Boulder, Colorado. 2012 IECC Energy Cost Compliance Property Organization DR Horton Homeowner EnergyLogic, Inc 2415 Palomino Dr (970) 556-0839 Ft Collins, CO 80525 Neal Girard Weather:Ft. Collins, CO Builder DR Horton DR Horton 2415 Palomino Dr DR Horton REM Annual Energy Cost HERS Confirmed 11/11/16 Rating No:42960 RaterID:4606190 energyLogic ...... i.. inaom. an...... $/yr 2012 IECC As Designed Heating 761 ...692 Cooling 286 _ 197 Water Heating .. 174 175 SubTotal - Used to Determine Compliance - 1220 10641 Lights Ft Appliances 1230• 1214 Photovoltaics =0 -0 Service Charge- y 240 240 Total 2690 25181 Mandatory Reauirements Annual Energy Cost Check PASSES a Duct Insulation R-Value Check (per Section 405.2) PASSES j Window U-Value and SHGCtheck: (per Section 402.5) PASSEStl Home Infiltration (Section 402.4.1.2) - `PASSES Duct Leakage (Section 403d:2) - PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation-FanEfficacy (Section°403r5.1) i=PASSES Mandatory Requirements Check Box (2012 IECC) - ', 'PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 12XovemZber2016 8% Name Neal Girard Signature Organization EnergyLogic, Inc Date 11 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. m 1985.2016 Noresco, Boulder, Colorado. 2012 IECC Certificate 2415 Palomino Dr, Ft Collins, CO 80525 Building Envelope Insulation Ceiling R-38.0 Above Grade Walls R-21.0 Foundation Walls R-19.0 Exposed Floor R-38.0 Slab R-0.0 Edge, R-0.0 Under Infiltration Htg: 2305 Clg: 2305 CFM50 Duct Uninsulated Total Duct Leakage 70.00 CFM ® 25 Pascals Window Data U-Factor w _ SHGC w Window 0.310 0.360 Mechanical Equipment HEAT: Fuel -fired air distribution, Natural gas, 92.1 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Natural gas, 0.59 EF, 50.0 Gal. Builder or Design Professional_m Signature REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 Property DR Horton DR Horton Homeowner 2415 Palomino Dr Ft Collins, CO 80525 Energy Rating • HERS Rating Type: Confirmed Rating Date: 11/11/16 Registry ID: 832392001 Certified Energy Rater: Neal Girard Rating Number: HERS Index: 55 General Information Conditioned Area 6311 sq. ft. House Type Single-family detached Conditioned Volume 64389 cubic ft. Foundation Conditioned basement Bedrooms 5 Mechanical Systems Features Water Heating: Conventional, Natural gas, 0.59 EF, 50.0 Gal. Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Duct Leakage to Outside 68.00 CFM25. Ventilation System Exhaust Only: 108 cfm, 30.0 watts. Programmable Thermostat Heat=Yes; Cool=Yes Building Shell Features Ceiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 Under Sealed Attic NA Exposed Floor R-38.0 Vaulted Ceiling NA Window Type U-Value: 0.310, SHGC: 0.360 Above Grade Walls R-21.0 Infiltration Rate Htg: 2305 Clg: 2305 CFM50 Foundation Walls R-19.0 Method Blower door test Lights and Appliance Features Percent Interior Lighting 100.00 Range/Oven Fuel Natural gas Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Refrigerator (kWh/yr) 1257 Clothes Dryer EF 2.67 Dishwasher (kWh/yr) 270 Ceiling Fan (cfm/Watt) 0.00 el 42960 energyLogic an n l v. I.. In.lyl. un...... Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 55.2 $652 27% Cooling 9.7 $99 4% Hot Water 16.6 $176 7% Lights/Appliances 44.2 $1214 51% Photovoltaics -0.0 $.0 -0% Service Charges $240 10% Total 125.6 $2381 100%- Criteria This home meets or exceeds the minimum criteria for the following: 2012 International Energy Conservation Code Home Energy Rating Provider EnergyLogic, Inc. P.O. Box N Berthoud, CO 80513 Phone k 1-800-315-0459 www.nrgLogic.com Certified Energy Rater: REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. O 1985-2016 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider.