HomeMy WebLinkAbout2051 Phia Way - Special Inspections/Engineering - 08/01/2019TD S R CTU -AP L ENGINEERING INC August 1, 2019 Habitat for Humanity Harry Aungst 4001 S Taft Hill Fort Collins, CO 80526 Observation Report Project: Duplex — Harmony Cottages Location: 2049 and 2051 Vhia Way, Fort Collins, Colorado TDSE Project No.: 17-019 Observation Dates: July 3111, 2019 Plans/Details: Plans by TD Structural Engineering Inc. dated 10/23/18 and revised 211/18 and 9/26/18 Items Observed: exterior shear wall connections and holdown strapping Notes: Observations indicate the exterior shear wall connections and holdowns are in substantial conformance with the plans as noted above. Sincerely, yPp0 L l�F MAS QNcP� c� fz P o 0 38181 ss/ONAL E��\5 . Wendy Thomas Dworak, P.E. President TD Structural Engineering Inc. TD Structural Engineering, Inc. 1 2909 Oxford Ct., Fort Collins, CO 80525 1970.372.1140 1 www.tdstructural.com February 22, 2019 Habitat for Humanity 4001 South Taft Hill Road Fort Collins, CO 80526 Attn: Mr. John Rowell (irowellAfortcollinshabitat.org) 191919EARTH ENGINEERIG COMPANYN INC. Re: Foundation D ain and Damp Proofing Observation 2049/2051 PL Way Harmony Cottages Fort Collins, Colorado EEC Project No. 17-01-120 Mr. Rowell: As requested, Earth Engineering Company, Inc. (EEC) personnel have completed the construction observation services you requested for the referenced project. Those services included observations of the foundation drain placement and damp proofing at the referenced lot. The results of those observations are included with this report. On February 20°i, 2019, EEC personnel observed the foundation drain for the referenced project. The foundation drain consisted of 4-inch perforated pipe bedded in gravel placed around the exterior and interior of the structure and was sloped to drain to a sump pit in the crawlspace of each unit. The gravel was covered in a filter fabric. The damp proofing consisted of a grey spray -on coating that appeared to cover all exterior below grade areas of the crawlspace walls. At the time of our observations, the foundation drain and damp proofing appeared to have been placed in general accordance with the construction plans We appreciate the opportunity to be of service to you on this project. If you have any questions regarding this report, or if we can be of further service to you in any way, please do not hesitate to contact us. Very truly yours, Earth Engineering Company, Inc. Michael J' Coje , P.E. Principal Engin er P.O. Box 271428, Fort Collins, CO 80527-addlll` phone: 970.775.2004 fax: 970.663.0282 TD ST 1UC URP�L ENGIN EK NG 1 C February 5, 2019 Habitat for Humanity 4001 S Taft Hill Fort Collins, CO 80526 o �� Observation Report Project: Duplex — Harmony Cottages Location: 2049 and 2051 Phia Way, Fort Collins, Colorado TDSE Project No.: 17-019 '— Observation Dates: January 171h and February 5'h, 2019 Plans/Details: Plans by TD Structural Engineering Inc. dated 10/23/18 Items Observed: footing and foundation wall sizes and reinforcing, UFER ground Notes: Observations indicate the footing and foundation sizes and reinforcing are in substantial conformance with the plans as noted above. In addition the UFER grounds were installed in accordance with NEC recommendations. Sincerely, o°° w N O< % 8? 38181 Wendy Thomas Dworak, P.E. President TD Structural Engineering Inc. TO Structural Engineering, Inc. 1 2909 Oxford Ct., Fort Collins, CO 80525 1 970.372.1140 1 www.tdstructural.com