Loading...
HomeMy WebLinkAbout4846 Northern Lights Dr - Disclosures/Blower Door Test - 11/11/2019 (2)Envelope Leakage Test Testing Company: Name: GS Services Ltd Address: 309 Lincoln Court Fort Collins, CO 80524 Phone: 970-449-1612 www.GSServices.com Building Information: Project ID: Landmark Homes Address: 4846 Northern Lights Dr Fort Collins, CO 80528 Geo-Tag Data: Latitude: 40.519220 Longitude:-105.003452 Timestamp: 2019-11-11 12:39:19 Technician: Name: Paul Higman Credentials: p /� Email: ,qu�r OT Customer Information: Name: Landmark Homes Address: Test Results: Measured Leakage: 2.50 ACH50 Leakage Target: 3.00 ACH50 Compliance with Leakage Target: Pass Test ID: Purpose of Test: Measured CFM50: Building Volume: Flow Coefficient (C): Correlation Coefficient: Test Standard: Test Characteristics: Test Date and Time: Unit A Env. Leakage 1,136.5 (+/- 1.0%) 27,248.0 W 76.6 (+/- 7.1 %) 0.99958 ASTM E779 (single mode) Pre Indoor Temp: 60 OF Pre Outdoor Temp: 25 OF Altitude: 4,931.0 ft 2019-11-11 16:24:55 o Depressurize — 1 �g� m 700 600 500 ca 3 400 rn 'v 300 m 200 100 i -- - — 4 5 6 7 8 910 Effective Leakage Area: 56.6 in' Enclosure Surface Area: 0.0 ft2 Exponent (n): 0.689 (+/- 0.020) Test Mode: Depressurize Post Indoor Temp: 64 OF Post Outdoor Temp: 25 OF Time Average Period: 10 seconds 20 30 Building Pressure (Pa) 40 50 6070 C Envelope Leakage Test (Page 2) Test Readings: Target Pa) Bldg -(Pal Adj BIda-(Pay Fan Pa) Flow cfm) Config Baseline -1.7 -60.0 -61.1 -58.3 -52.8 1,315.2 Ring A -54.0 -55.4 -52.6 -45.1 1,218.1 Ring A -48.0 -49.3 -46.5 -38.6 1,129.3 Ring A -42.0 -43.2 -40.3 -31.9 1,029.1 Ring A -36.0 -37.8 -35,0 . -26.5 938.9 Ring A -30.0 -31.0 -28.2 -186.2 808.6 Ring B -24.0 -26.6 -23.8 -143.6 711:0 Ring B -18.0 -20.6 -17.8 -93.7 575.4 king B Baseline -3.9 Test Equipment: Flow Device: . - Model.3 Fan Pressure Gauge: DG700 Serial #: 41761 Calibration Date: 2018-12-26 Deviations from Standard: e None Comments: