HomeMy WebLinkAbout4846 Northern Lights Dr - Disclosures/Blower Door Test - 11/13/2019• '� BUILDING LEAKAGE TEST SL11 ..• �•'GS Services, LTD. ,P)e� 309 Lincoln Court - Fort Collins, CO 80524 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 11/13/2019 Customer: Landmark Homes Test File: Landmark - 4846 Northern Lights Drive Unit B - BDma Technician: Nick Hiseler f� // J� Project Number: / ,ll� aTit�� Building Address: 4846 Northern Lights Drive UatBl Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1001 CFM50 (+/- 3.9 %) (50 Pa = 0.2 w.c.) 2.94 ACH50 2. Leakage Area: 55.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 72.6 (+/- 11.7 %) Exponent (n) = 0.671 ( +/- 0.037 ) Correlation Coefficient = 0.99849 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling 6e BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/13/2019 Test File: Landmark - 4846 Northern Lights Drive Unit B - BDma Building Information Volume 20416 Surface Area FloorArea Height # of Bedrooms # of Occupants Year of Construction 2019 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128` Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 l GS`SerIIB;; BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/13/2019 Test File: Landmark - 4846 Northern Lights Drive Unit B - BDma Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 67.0 59.0 4931.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -11.4 n/a n/a -60.0 -47.8 28.6 975 990 2.0 Ring A -54.0 -41.8 219.8 878 891 0.5 Ring B -48.0 -35.8 182.7 801 813 1.8 Ring B -42.0 -29.8 132.8 684 694 -1.7 Ring B -36.0 -23.8 102.3 601 610 0.5 Ring B -30.0 -17.8 63.6 475 482 -3.5 Ring B -24.0 -11.8 246.7 361 367 -3.3 Ring C -18.0 -5.8 111.4 240 244 3.9 Ring C -1 3.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None GSs -------- BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/13/2019 Test File: Landmark - 4846 Northern Lights Drive Unit B - BDma Comments Detached Garage