Loading...
HomeMy WebLinkAbout202 Stoney Brook St - Special Inspections/Field Verification - 01/22/2019Planning, Development & Transportation Ser-trices C . ®f Community Development & Neighborhood Services 6 ■ 281 North College Avenue ® �o 'ns P.O.liox580 �wti� Fort Collins, CO 80522.0580 �,_ 970A16.2740 970.224.6134- fax fcrov cam Asbestos Statement Disclosure1 00490 � d_ 1 Address Permit # In accordance with the State of Colorado Senate Bill 13452, property owners, applying for a remodel permit, shall indicate their awareness about their property having been inspected for Asbestos Containing Materials (ACMs). Property owner, please check the appropriate box below and sign: ❑ I do not know if an asbestos inspection has been conducted on this property. E(�n asbestos inspection has been conducted on this property on or about 9 /!S ❑ An asbestos inspection has not been conducted on this property. ZAIII r l Z 2 Signature QQ Date I� Y Je4 Gd-' J Your remodel project may be subject to State and Federal Regulations requiring an inspection for ACMs. Asbestos can be found in these and many other building materials: ceiling tiles and textures, vinyl floor coverings and mastic, boiler and pipe insulation, heating and cooling duct insulation, roofing products and clapboard shingles, etc. For more information aboutAsbestos or forms, please contact: Asbestos Compliance Assistance Group Toll Free: 1-800-886-7689 Phone: (303) 692-3100 https:/lwww.colorado.gov/pacific/sites/default/files/AP ASB RenovationDemolition.pdj https: //www. codorado. gov/cdphelasbestos Email address: cdphe.asbestos6E�state.co.us Page 1 of 1 ASBESTOS ABATEMENT FINAL VISUAL INSPECTION F �i1 0 4 4 ti Facility aq� (O-VI-y/' la Inspected By 4w,/ Phase / Containment W �� d?a� 1aejN� Final Visual Beg/Pass Dates Ja Contractor/Supervisor I ESW , 3 Final Clearance Bcg/Pass Dates J Containment Type ❑FFull ❑Secondary r1 QOther Descri Han of Area: O¢ f i a-r W XA d o­j jr Co--.a.A.est VqA Abatement Methods ❑ Gross removal ❑ Non -friable CaCoTponent Scope of Work/Materials Removed: b uwOt ❑ Glove -bag ❑ Other wr�A)A—J a ^L/ �2 FINAL VISUAL INSPECTION SUMMARY FINAL VISUALINSPECTION (PRE, LOCIO30WN) Description All asbestos within the scope ofavork is removed. No residual debris, dust or streaking an floors No residual debris, dust or streaking on walls No residual debris, dust orstreaking on ceilings No residual debris, dust or streaking on on teal barriers or other surface covered by poly No residual debris, dust or streaking on piping, nip ofducts, or other mechanical equipment No residual debris, dust or streaking between decks and beams, behind eolumas All protective Primary and Secondary barriers removed with only critical barriers in place No residual dust, debris or streaking on hangers, light furlures, or other fixed objects / surfaces within containment. Negative pressure containment continually operating. New prefilters and secondary filters installed in negative air machines All waste containers removed front area, labeled and stored. All equipment dean Attached decontamination unit and waste load out units cleaned, with no residual debris, dust or streaking. Number of Inspections Required to Pass ( )2 ( )3 ( )4 ()5 t,ommerraal receinal Fan =-6= UFM (hlghl -EO' of air travel Descri Ilon Commenls High Volume Pumps >3205011` ndnimumof5 plus 1,_a205011`2 minimum, <3s031f I minimum -.Cassettes 0.80pm 25mm MCE cassettes, I lab and l field blank for each set Extension Cords/GFCI GFCI Protected Surge Prefemore/Outlets .11ap Leafblower Leafblow, each 1.000 sq a within the work ores for a duration of5 minutes flttach sketch or dralving ofcontainment coqfigurarron LEGEND ✓=OK Y=Defciency/Correction Required —=N/A Irerracan CONSULTING ENGINEERS AND SCIENTISTS AREAS REQUIRING FURTHER CLEANING: t'f p �� W11n /J� s (i L# ie-e (o O 6,L a 9 col PLO,�Ss Q11 c6.:�cQ` w Date Aonlyaed: Laboratory: AIHA/NVLAP o: ,PASSED ( ) FAILED C RANCE STANDARDS Comments: ' Inspector's Signature Date / Time ®=Deficiency Corrected Final Visual Inspection Form (Rev 07114