HomeMy WebLinkAbout3033 Crusader St - Disclosures/Mechanical - 07/09/2018Testing date(s)
Bath exhaust
Kitchen exhaust
Minimum airflow requirement (CFM 5000') + operation
Measured airflow
Indicated flow CFM Volumetric flow CFM 5000' Pass Fail
Date of "Residential
Mechanical Systems
Design Submittal"
information referenced
by testing technicians
2. Local Exhaust (Spot Ventilation)
__ Flow box
__ Passive flow hood
Fail Caution
Other
data
ADCF = Air Density Correction Factor, based on tool,
altitude (5000'), air temperature through tool
Volumetric flow (CFM 5000') = ADCF x Indicated flow (CFM)
Testing tech (initials)
As-built changes vs
mech design submittal
This form is a record of testing targets and results, with Pass/Fail outcomes. For information on measurement tools and testing techniques, see the
"Residential New Construction Mechanical Systems Testing Guide." The guide and this form may be periodically updated; check the Building
Services web site for the current version.
This form must be completed and signed by an "Approved Agency," and submitted to Building Services as a requirement for receiving a C.O.
HVAC contractor
Address
Builder
Measured value
to compare with
target or limit
1. House Data
ADCF
Color
key
Target
or limit
Pass
Pass
__ Pitot tube duct traverse
__ Other (note below)
Flow
tool
Minimum Airflow Requirement
(CFM 5000')
+ Type of Operation
__ 50 Intermittent __ 20 Continuous
__ 50 Intermittent __ 20 Continuous
__ 50 Intermittent __ 20 Continuous
__ 50 Intermittent __ 20 Continuous
__ 50 Intermittent __ 20 Continuous
__ 50 Intermittent __ 20 Continuous
__ 50 Intermittent __ 20 Continuous
Fail
ADCF
ADCF
Flow
Systems other than sub-structural floor exhaust
CFM 5000' CFM 5000'
to CFM 5000'
When supply airflow is circulated by air handler fan, fan speed for measurement
Balanced airflow in balanced systems
Pass Fail
Sub-structural floor exhaust N/A -- no sub-structural floor exhaust system
CFM 5000' CFM 5000'
Measured airflow
Indicated flow CFM Volumetric flow CFM 5000' Pass Fail
sf
System #1 System #2
Pass Fail
__ No ductwork
__ No ductwork outside conditioned space
Testing notes
(incl multiple sys)
Indicated
(CFM25) (CFM25 5000')
Volumetric
Timing Air Handler
Complete Included 12
Rough-in
Complete
__ Testing tech (initials):
__ Energy rater (name,
company, testing date):
Normalized Absolute
Maximum Allowed Duct Leakage
(CFM25 5000' / 100 sf)
ADCF
N/A
Rough-in Excluded 4
(CFM25 5000')
Average of measured
supply + exhaust flows
CFM
5000'
Target flow range
(average +/- 15%)
to
CFM
5000'
__ N/A
__ Flow box
__ Flow collar
__ Passive flow hood
__ Pitot tube traverse
__ Other (note below)
Measurement Method
Testing tech (initials)
For multiple systems, attach one page per system
Installed equipment (Be clear about which AC components are installed at time of testing)
Static pressures
Cooling: Measured air flow through indoor coil N/A -- no AC installed
CFM 5000' CFM 5000'
Measured airflow
CFM Pass
5000' Fail
Heating: Gas manifold pressure (high stage)
Pass
Fail
Heating: Temperature rise
F
Measured temps (F): − = Pass Fail
NSOP TFSOP
Testing tech (initials)
Testing tech (initials)
Testing tech (initials)
Filter
brand
Type
__ Electrostatic
__ Other:
__ Basic fiberglass
__ Basic pleated
__ High-effic pleated
Model #
Furnace or Boiler AC or Heat Pump Condenser AC or Heat Pump Coil
MERV
(optional)
Thickness
(inches)
Manufacturer
5. Heating + Cooling Equipment
System # Which parts of house does it serve?
Flow grid
plate size
__ 14
__ 20
Air temp
through
tool (F)
ADCF
CFM
Measured airflow, no
adjustment/correction
Indicated airflow
Measured AF x FRCF
Volumetric airflow
Indicated AF x ADCF
OEM temperature rise limits to
(high stage)
Measured
pressure
Testing tech (initials)
Testing tech (initials)
Target airflow limits
(design +/- 15%)
Design cooling airflow
(high stage)
Testing approach and targets
N/A: No complete AC system N/A: House completed November - April (installing contractor responsible for testing in warm weather)
TXV: Subcooling + SH check Non-TXV: Superheat OEM-specific: Approach Other OEM-specific
(documentation required)
Subcooling
F F F
TXV Fail
Superheat
F F F
Non-TXV Fail
Pass: Field-installed TXV installed in accordance with OEM instructions Caution: Actual SH outside mfgr range
Approach
Approach Pass: Actual approach within +/- 1 F of target approach
Approach Fail
Register air flows
Pass Fail
(Remainder of register air flow section under development, not yet being enforced)
Pressure balance
TXV checks:
Actual approach
(Liq line T - condenser EAT)
Liquid line
temp
F F
Temperatures
(F):
Condenser
entering air temp
Target
approach
Target
superheat
Non-TXV: Return
air wet-bulb temp
-3 to +3
-3 to +3
-3 to +3
-3 to +3
-3 to +3
-3 to +3
-3 to +3
-3 to +3
Testing tech (initials)
Testing tech (initials)
-3 to +3
-3 to +3
All registers are cut through finish materials and moving air
Measured
Pressure
Drop (Pa)
Pass Fail
Room-to-Core
Pressure Drop
Target Range (Pa)
Room
(match names on plans, include
basement if there is a door)
Appliance types
Worst-case depressurization performance
House setup
F
CAZ pressure
BPI depressurization limit (Pa wrt outside)
Measured net CAZ depressurization (Pa wrt outside)
OK (less negative) | Caution (more negative)
Spillage
BPI maximum limit
Measured spillage duration
Pass = duration not exceeding limit
Draft pressure
BPI limit
Measured
Pass = pressure more negative than limit
CO concentration in undiluted flue gas
BPI maximum limit
Measured CO
Pass = CO level not exceeding limit
Caution = CO level 25 to 100 ppm
Tested appliances
Outdoor temperature Appliance
Location
Boiler #2
Combustion safety testing N/A -- no natural-draft combustion appliances
(Appliance Types table must be completed for every home)
8. Combustion Safety
Furnace #1
Furnace #2
Appliance
Testing tech (initials)
OK Caution OK Caution
OK Caution
60 60 60
Pass Fail Pass Fail Pass Fail
Fail Pass Fail
Pass Fail Pass Fail
Pass Fail
Caution Caution Caution
(seconds)
(seconds)
(Pa wrt CAZ)
(Pa wrt CAZ)
(ppm)
(ppm)
100 100 100
Pass Fail Pass
N/A
Electric
Combustion Type
Other:
Technician #1 performing inspection and testing documented on this report (Approved Agency)
Technician #2 performing inspection and testing documented on this report (Approved Agency)
HVAC Contractor (City of Fort Collins license holder)
Local exhaust (all fans)
Whole-house ventilation
Sub-structural floor exhaust
Heating (all systems)
Cooling (all systems)
9. System Controls
System
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Signatures
Name (print)
Title
Company
Signature and Date
N/A
I certify that the tests referenced above, in sections bearing my initials, were performed in accordance with protocols specified by the
City of Fort Collins Building Services Department, and that the reported results are accurate to the best of my knowledge.
Title
Company
Signature and Date
Name (print)
Title
Company
Signature and Date
Name (print)
Testing tech (initials)
I certify that the tests referenced above, in sections bearing my initials, were performed in accordance with protocols specified by the
City of Fort Collins Building Services Department, and that the reported results are accurate to the best of my knowledge.
I certify that I have reviewed this report and that the test results are an accurate representation of the performance of the installed mechanical
systems.
Testing Notes
N/A
Controls Operating
Per Design Intent
N/A
N/A
N/A
Residential Mechanical Design Submittal V20140101 Page 6
Draft-hood
(Natural-draft)
Induced-draft
(Natural-draft)
Power-
vent
Direct-
vent
Powered sealed-
combustion
Fireplace #1
Fireplace #2
Water heater #1
Water heater #2
Boiler #1
Testing
notes
____ # of bath fans on
____ Vented range hood on
____ Clothes dryer on
____ Air handler on
These doors are closed:
Other fans on: Other setup notes:
Residential Mechanical Design Submittal V20140101 Page 5
Discharge
pressure
(PSI)
Condenser
saturation T
(5000' chart)
Testing tech (initials)
Target
subcooling
6. Refrigerant Charge
TXV Pass: Actual SC within +/-
3 F of target SC, 2 F min
Liquid
line
temp
Actual
subcooling
(Cond T - liq line T)
Non-TXV Pass: Actual SH
within +/- 5 F of target SH
Suction Evaporator Suction Actual
pressure saturation T line superheat
(PSI) (5000' chart) temp (Suct line T - evap T)
7. Room Air Flow + Pressure Balance
Testing
notes
Residential Mechanical Design Submittal V20140101 Page 4
to
OEM spec @ 5000'
to
Flow Resistance
Correction Factor
CFM
Testing
notes
Target manifold P
limits (spec +/- 5%)
Manifold pressure
Caution: within 10F
of top of range
Temp
rise
Supply
air
Return
air
IWC IWC IWC
SP1
Setup
Speed: __ Heating __ Cooling __ Cont. fan
__ High-stage for multi-stage equipment
Blower speed tap: _______________________
Humidifier damper: __ N/A
__ Open (Heating)
__ Closed (Cooling)
___ All registers open
___ Zone dampers open
SP2
∆P Filter
(SP1 - SP2)
SP3
SP4
∆P Coil
(SP3-SP4)
∆P Total ESP
(SP3-SP2)
(Same location
for NSOP,
TFSOP)
Residential Mechanical Design Submittal V20140101 Page 3
4. Heating + Cooling Duct Leakage
Duct leakage
data source
Testing
notes
House conditioned floor area
(include full basement)
Pass Fail
Air temp
through
tool (F)
__ Pitot tube traverse
__ Flow collar
__ Other (note below)
Tool
location
Air temp
through tool (F)
__ Flow box
__ Passive flow hood
__ Powered flow hood
Included 8
Included 6
Leakage Type
Total leakage
Total leakage
Total leakage
Leakage
to outdoors
Test Parameter and Conditions
Measured Duct Leakage
Testing
notes
ADCF
Flow
tool
Indicated
Flow
(CFM)
Volumetric
Flow
(CFM 5000')
Measured Airflow
Pass
3. Whole-Dwelling-Unit Ventilation
Testing tech (initials)
__ Passive flow hood
__ Pitot tube traverse
__ Other (note below)
__ N/A
__ Flow box
__ Flow collar
Fail
Design ventilation
airflow
Target airflow limits
(design +/- 15%)
to
Design exhaust airflow (based on
approved design)
(code-minimum) (120% of design flow)
Target ventilation airflow range
System
type
__ Exhaust-only
__ Supply-only
__ Balanced
Code-minimum ventilation airflow
(based on CFA and # of BR)
__ Heating __ Cooling __ Continuous fan
Total
exhaust
airflow
Total
supply
airflow
ADCF
Air Temp
Through
Tool (F)
Tool Location
Residential Mechanical Design Submittal V20140101 Page 2
tool
__ Flow box
__ Passive flow hood
__ Powered flow hood
N/A - hood does not vent to outside Testing tech (initials)
Tool
location
Oven fuel __ Gas __ Electric __ 100 Intermittent __ 25 Continuous
Air temp
through
tool (F)
__ Interior grille
__ Exhaust duct
(Exterior termination not OK)
__ Pitot tube traverse
__ Flow grid
__ Other (note below)
City of Fort Collins Residential Mechanical Systems Performance Report
Indicated
Flow
(CFM)
Volumetric
Flow
(CFM 5000')
Measured Airflow
Exhaust Pickup Location
Design
Airflow
(CFM
5000')
Testing
notes
Air temp
through tool (F)
Testing
notes
Residential Mechanical Design Submittal V20140101 Page 1