Bldg: 36
Multi-Family Inspection Summary Report by Unit
06/20/2017
Inspection Performed By:
Trevor Donnelly
trevor.donnelly@nrglogic.com
Subdivision:
Capstone Collegiate Communities
Supervisor:
Robert Ambrose
Buildings:
Inspected for the following programs/codes:
INSPECTION RESULTS: Builder Sign Off Required
Builder sign-off items must be corrected. See details on following pages for explanation of items requiring re-inspection.
Units Passed: Units to Address:
Bldg: 36 Unit: 3
Bldg: 36 Unit: 1
Bldg: 36 Unit: 2
EnergyLogic, Inc
(970) 556-0839 · www.nrglogic.com
PO Box N, Berthoud, CO 80513
Thank you for using EnergyLogic, Inc for your home inspections.
Prepared for:
Cottage Builders, Inc.
1206 Gold Drive - Units 1 - 3
Builder Rough Energy Inspection Report
Bldg: 36 Unit: 1
Inspection Item Program Codes
Continuous sealed top & bottom plates or sealed blocking
using silicone caulk, latex foam, or equivalent material
Result:
IECC 09/12/15
ESv3 - 4.4 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Bottom plates can use a second
application of foam once fully
cleaned and right before drywall/
after if they leave a gap
Inspection Item Program Codes
Party walls: gap between common wall and structural
framing between units fully sealed (Fire code issues may
apply)
Result:
IECC 2012/2015
ESv3 - 4.8 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Party wall bottom plate not foamed!!
Inspection Item Program Codes
Window & Door Frames foam, caulked, or sealed to house
framing
Result:
IECC 09/12/15
ESv3 - 4.6 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
windows not installed yet
Inspection Item Program Codes
Mechanical System #1 2012 IECC Total Duct Leakage:
Max leakage is 4% of conditioned floor area. (Does not
apply if 100% of ducts in conditioned space.)
Result:
IECC 2012
IECC 2015
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Great job! Target 34 Tested 25
Bldg: 36 Unit: 2
Inspection Item Program Codes
Electric wiring: Penetrations to unconditioned space
sealed
Result:
IECC 09/12/15
ESv3 - 4.1 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
I missed this in the first two units so
please check there as well but the
front dropped ceiling/ attic area has
wire penetrations that are not
foamed
Inspection Item Program Codes
Plumbing/piping: Penetrations to unconditioned space
sealed
Result:
IECC 09/12/15
ESv3 - 4.1 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Plumbing into attic platform needs
foam
Inspection Item Program Codes
Continuous sealed top & bottom plates or sealed blocking
using silicone caulk, latex foam, or equivalent material
Result:
IECC 09/12/15
ESv3 - 4.4 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Bottom plates can use a second
application of foam once fully
cleaned and right before drywall/
after if they leave a gap
Inspection Item Program Codes
Party walls: gap between common wall and structural
framing between units fully sealed (Fire code issues may
apply)
Result:
IECC 2012/2015
ESv3 - 4.8 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Wire pens into party wall on first
floor- please check on other units as
well Party wall bottom plate not
foamed!!
Inspection Item Program Codes
Window & Door Frames foam, caulked, or sealed to house
framing
Result:
IECC 09/12/15
ESv3 - 4.6 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Some windows could use touch ups-
please review all windows
Inspection Item Program Codes
Mechanical System #1 2012 IECC Total Duct Leakage:
Max leakage is 4% of conditioned floor area. (Does not
IECC 2012
IECC 2015
apply if 100% of ducts in conditioned space.)
Result:
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Great job! Target 34 Tested 26
Bldg: 36 Unit: 3
Inspection Item Program Codes
Continuous sealed top & bottom plates or sealed blocking
using silicone caulk, latex foam, or equivalent material
Result:
IECC 09/12/15
ESv3 - 4.4 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Bottom plates can use a second
application of foam once fully
cleaned and right before drywall/
after if they leave a gap
Inspection Item Program Codes
Party walls: gap between common wall and structural
framing between units fully sealed (Fire code issues may
apply)
Result:
IECC 2012/2015
ESv3 - 4.8 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Party wall bottom plate not foamed!!
Inspection Item Program Codes
Window & Door Frames foam, caulked, or sealed to house
framing
Result:
IECC 09/12/15
ESv3 - 4.6 RFC
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Some windows could use touch ups
Inspection Item Program Codes
Mechanical System #1 2012 IECC Total Duct Leakage:
Max leakage is 4% of conditioned floor area. (Does not
apply if 100% of ducts in conditioned space.)
Result:
IECC 2012
IECC 2015
Inspection Date Action Needed Photo
06/20/2017
Where/Description
Great job! Target 34 Tested 19
Passed
Builder Sign Off - Builder will correct item without re-inspection
Failed
Failed - Builder must submit photo of correction in lieu of re-inspection
Prepared By: Trevor Donnelly