HomeMy WebLinkAbout4786 Mcmurry Ave - Disclosures/Blower Door Test - 04/26/2018 (3)April 26th, 2018 TO: Keith Holmes, Harmonic Construction; Dave Lenort & Kenny McMillan, Brinkman Construction FROM: Sarah Allison, Lightly Treading, Inc. RE: Final Comprehensive Report – Air Tightness Blower Door, Duct Leakage & Mechanical Ventilation Testing Air Tightness Testing: We performed Air-Tightness testing using Energy Conservatory Blower Door technology on a a minimum of 20% of the units in the building. A sampling of 23 units and 3 commercial spaces at Oakridge Crossing located at 4786 McMurry Ave, Fort Collins were tested against City of Fort Collins air-leakage requirements. The test results are as follows: Unit # Conditioned Floor Area Surface Area of Unit Fort Collins code maximum air-leakage @50pa (0.3CFM per ft2 of surface area) Tested air- leakage @ 50 pa Pass/Fail 120 529 ft2 2,074 ft2 622 CFM 585 CFM PASS 123 826 ft2 3,025 ft2 907 CFM 658 CFM PASS 130 529 ft2 2,074 ft2 622 CFM 507 CFM PASS 135 826 ft2 3,025 ft2 907 CFM 609 CFM PASS 150 529 ft2 2,074 ft2 622 CFM 617 CFM PASS 156 529 ft2 2,074 ft2 622 CFM 599 CFM PASS 210 826 ft2 2,773 ft2 832 CFM 544 CFM PASS 213 826 ft2 2,773 ft2 832 CFM 445 CFM PASS 228 529 ft2 1,971 ft2 591 CFM 475 CFM PASS 237 529 ft2 1,971 ft2 591 CFM 439 CFM PASS 241 826 ft2 2,773 ft2 832 CFM 579 CFM PASS 2 248 529 ft2 1,971 ft2 591 CFM 466 CFM PASS 251 826 ft2 2,773 ft2 832 CFM 509 CFM PASS 253 529 ft2 1,971 ft2 591 CFM 439 CFM PASS 302 826 ft2 2,773 ft2 832 CFM 766 CFM PASS 310 529 ft2 1,971 ft2 591 CFM 574 CFM PASS 315 529 ft2 1,971 ft2 591 CFM 551 CFM PASS 327 529 ft2 1,971 ft2 591 CFM 499 CFM PASS 337 826 ft2 2,773 ft2 832 CFM 673 CFM PASS 341 529 ft2 1,971 ft2 591 CFM 485 CFM PASS 342 529 ft2 1,971 ft2 591 CFM 438 CFM PASS 347 826 ft2 2,773 ft2 832 CFM 600 CFM PASS 350 529 ft2 1,971 ft2 591 CFM 487 CFM PASS Location Conditioned Floor Area Surface Area of Unit Fort Collins core maximum air-leakage @50pa (0.25CFM per ft2 of surface area) Tested air- leakage @ 50 pa Pass/Fail 1st Floor Commercial Space 2,770 ft2 9,542 ft2 2,385 CFM 1,780 CFM PASS Billiards Room 303 ft2 1, 242 ft2 310 CFM 247 CFM PASS Computer Room 182 ft2 876 ft2 219 CFM 218 CFM PASS - All residential units met and exceeded City of Fort Collins air-leakage requirement for multi-family new construction; 0.30 CFM@50Pa/ ft2 - All commercial areas met and exceeded City of Fort Collins air-leakage requirements of 0.25 CFM@50Pa/ ft2 3 Multifamily Test & Balance Criteria Checklists: - Local Exhaust (spot ventilation): all bath fans operating at a minimum of 50 cfm intermittent or 20 cfm continuous. - Whole House Ventilation: meets code minimum air flow & is within code minimum to +120% of design flow. o Code minimum and the design flow was agreed upon 84 cfm at the following specific set hours per day for individual units: ▪ 1 BR Units that need 9.6 hours of ventilation per day = 85 units • 1st Floor: 159, 156, 155, 154, 153, 152, 151, 150, 149, 143, 142, 141, 139, 136, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 123, 120 • 2nd Floor: 253, 250, 249, 248, 247, 246, 245, 244, 243, 239, 238, 237, 236, 235, 231, 229, 228, 227, 226, 225, 224, 223, 222, 221, 219, 217, 216, 212, 211, 208 • 3rd Floor: 350, 346, 345, 344, 343, 342, 341, 340, 339, 335, 334, 333, 332, 331, 327, 325, 323, 322, 321, 320, 319, 318, 317, 316, 315, 313, 310, 307, 306 ▪ 2 BR Units that need 14.5 hours of ventilation per day = 2 units • 1st Floor: 144, 135 ▪ 2 BR Units that need 14.3 hours of ventilation per day = 1 unit • 3rd Floor: 300 All units were tested against the City of Fort Collins standards for local exhaust and whole house ventilation. 100% of the units passed above requirements and have been verified by Lightly Treading. Please contact me with any questions. Take care, Sarah Allison Technical Consultant Lightly Treading, Inc.