Loading...
HomeMy WebLinkAbout6009 Sapling Ct - Disclosures/Blower Door Test - 08/30/2018BUILDING LEAKAGE TEST Date of Test: 08/30/2018 Test File: 6009 Sapling Court Technician: Jay Bundy Project Number: Customer: Toll Brothers 10 Inverness E Dr Ste 125 Englewood, CO 80112 Phone: 303-708-0730 Building Address: Toll Brothers 6009 Sapling Court Fort Collins, Colorado 80528 Test Results 1. Airflow at 50 Pascals: 1200 CFM50 (+/- 1.3 %) (50 Pa = 0.2 w.c.) 2.61 ACH50 2. Leakage Area: 66.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 125.0 (+/- 21.1 %) Exponent (n) = 0.578 (+/- 0.055) Correlation Coefficient = 0.99658 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 55.1 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 83.6 CFM 0.18 ACH Summer: 49.3 CFM 0.11 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 08/30/2018 Test File: 6009 Sapling Court Building Information Volume 27562 Surface Area 7043 Floor Area 2561 Height 9 # of Bedrooms 2 # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 08/30/2018 Test File: 6009 Sapling Court Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 69.0 65.0 4980.0 Data Points - Data Entered Manually (TT 4.0.53.0) Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.0 n/a n/a -65.0 -61.5 55.3 1345 1357 0.3 Ring A -60.0 -56.5 455.7 1260 1272 -1.3 Ring B -55.0 -51.5 413.0 1200 1211 -0.8 Ring B -50.0 -46.5 389.1 1165 1176 2.1 Ring B -45.0 -41.5 330.8 1075 1085 0.7 Ring B -40.0 -36.5 279.0 988 997 -0.4 Ring B -35.0 -31.5 233.7 905 913 -0.6 Ring B -3.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters - Fewer than 8 data points were taken. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 08/30/2018 Test File: 6009 Sapling Court Comments Garage with Respect to House @50PA = 46.7 Pa