Loading...
HomeMy WebLinkAbout1042 W Mountain Ave - Disclosures/Blower Door Test - 04/05/2018BUILDING LEAKAGE TEST GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 4/5/2018 Test File: Savant Homes - 1042 W Mountain Avenue - BD2 Technician: Nick Hiseler Project Number: Customer: Savant Homes Building Address: 1042 W Mountain Avenue Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 827 CFM50 ( +/- 2.0 %) (50 Pa = 0.2 w.c.) 2.85 ACH50 2. Leakage Area: 45.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 64.0 ( +/- 13.0 %) Exponent (n) = 0.654 ( +/- 0.037 ) Correlation Coefficient = 0.99844 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/5/2018 Test File: Savant Homes - 1042 W Mountain Avenue - BD2 Building Information Volume 17400 Surface Area Floor Area 1787 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 19028 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/5/2018 Test File: Savant Homes - 1042 W Mountain Avenue - BD2 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 69.0 30.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.8 n/a n/a -60.7 -58.0 28.7 977 939 3.0 Ring A -48.4 -45.7 186.4 809 777 -0.3 Ring B -48.6 -45.9 186.8 810 778 -0.5 Ring B -44.8 -42.0 164.8 761 731 -1.0 Ring B -38.7 -36.0 132.3 683 656 -1.7 Ring B -32.4 -29.7 104.3 607 583 -0.9 Ring B -25.8 -23.1 76.1 519 499 -0.1 Ring B -18.9 -16.2 49.2 418 402 1.6 Ring B -3.7 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4/5/2018 Test File: Savant Homes - 1042 W Mountain Avenue - BD2 Comments Detached Garage