Loading...
HomeMy WebLinkAbout5926 Tilden St - Applications/Single Family New - 10/11/2018City of COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES Fort Collins IS 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970-416-2740 / www.fcgov.com/building BUILDING PERMIT APPLICATION APPLICATION NUMBER_A ) q 1()APPLICATION DATEiO/ It /1 8 Job Site Address 5926 Tilden St Unit # PROPERTY OWNER INFO: (All owner information is required - it is not optional) Phone # 720-977-3872 Last name Robbins First Name Amanda Middle Street Address 4350 S. Monaco St. city Denver State CO Zip 80237 CONTRACTOR INFO: Company Name Lic Holder Name Tom Rigg Richmond American Homes Contractor Phone # 720-977-3822 City of Fort Collins License # D-342 Supervisor Cert # Mailing Address same as owner City State LEGAL INFO: subdivision/PUD Mail Creek Crossing Filing # 1 Lot # 1 CONSTRUCTION INFO: Total Building Sq Ft (not including basement) 3042 Block # 9 Lot Sq Ft 8237 Total Garage Sq Ft 455 Residential Sq Ft 4348 Comm] Sq Ft n/a # of Stories 2 Bldg Height 30.5' # Dwelling Units 1 1 �' Floor Sq Ft 1408 2nd Floor Sq Ft 1634 3° Floor SgFt= Unfiished Bsmt Sq Ft 1306 Finished Bsmt Sq Ft - # of Bedrooms 5 # of Full Baths 3 3/4 Baths /z Baths # of Fireplaces Air Conditioning: Ye-/Nou Energy info: ( Circle appropriate choice) 1. ComCheck ❑ 2. ResCheck w/Air Sealing11 3. ResCheck w/Blower Door ❑ 4. Simulated Performance Alternative 5. Prescriptive w/Air Sealing 11 6. Prescriptive w/ Blower Doom City of Fort Collins Stock Plan # SP02173 List appropriate option UTILITIES INFO: Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes Fv—/]NoF—1 Temp. Pedestal Yes[Z] No 0 Type of Heat: Fvl( Gas ❑Electric Electric Main Breaker Size (Residential only) W1150 Amp or Less 0 200 Amp Other Value of Construction (including labor, material & profit) $ 3#7;r 621 . 3 3 4, 40 Description of Work: D29A, Elev A, Ext Great Rm,:3-Car, Opt Bed #5 and bath #3, FP@FR, full SOG, A/C, Contact Name & Phone # of JOBSITE SUPERVISOR: Tom Rigg 970-381-8305 Subcontractor Info: Electrical Courtesy Electric Mechanical Allied Heating & A/C Plumbing Confidence Plumbing Framer Superior Image Construction Roofing D-7 Roofing Concrete J&C Foundations Solar n/a Other Other Fireplace Rio Grande Co Other Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City of Fort Collin ordinance and stale laws regulating building construction. Applicant Signature �W i PrintNameAmanda Robbins Phone 720-977-3872 Distribution: White - Office Yellow - Applicant Pink - WWvV/Stormwaler THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE City of Updated 08/23/2017 Fart Collins Planning, Development & Transportation Services Community Development & Neighborhood Services 2015 IRC — FORT COL I R SI N IAL ENERGY CODE COMPLIANCE FORM FORM 1— Use this form for single family houses, duplex, townhouses, or multi family up to 3 stories Permit Number: Address:5926 Tilden St - Lot 1/9 DIRECTIONS: Place a check (✓) next to Prescriptive, UA, SPA or ERI indicating the path chosen. An air tightness Blower Door Test is required of all paths and must be equal to or less than 3 ACH50 (not applicable to additions). Electrically heated buildings are required to use the prescriptive path (A). (A) PRESCRIPTIVE compliance for house, 2015 IRC, section Nh02.11 Climate Zone 5 BUILDING ENVELOPE INSULATION R-VALUE ELECTRICALLY HEATED R-VALUE Roof insulation in attic R-49 R-49 Roof rafter insulation R-30 R-30 Wood frame wall insulation R-20 or R-13+R-5ci* R-20 + R-5ci* Crawl space wall R-15ci*/19 or R-10ci*/13 w/ R-15 spray foam at rim joist R-15ci*/19 Wood floor (over unconditioned space) R-30 R-30 Walls below grade R-15ci*/19 or R-10ci*/13 w/ R-15 spray foam at rim joist R-15ci*/19 Slab on grade floor (insulation must extend to top of slab) R-10, 24" deep R-10, 36" deep Windows U-0.32 U-0.30 *ci denotes Continuous Insulation (ie: insulation such as rigid foam board that's not broken by framing cavity) (B) TOTAL UA ALTERNATIVE (REScheck), 2015 IRC, section: N1102.1.5 Submit a passing UA calculation (REScheck) using 2015 IRC/IECC. The rating must be submitted at time of application and must include address of residence, name of individual completing the rating form. name and version of software tool (i.e. REScheck). (C) SIMULATED PERFORMANCE ALTERNATIVE, 2015 IECC, section R405 An energy rating system (HERS rating) must be utilized using approved and current software tools such as REM/Rate, Ekotrope, or EnergyGauge. A preliminary/projected rating passing 2015 IECC must be submitted at time of application. Rating must include Address, Name of certified Energy Rater, and version of software. Final ratings require a blower door test and must be submitted for certificate of occupancy. (D) ENERGY RATING INDEX (ERI) COMPLIANCE ALTERNATIVE, 2015 IECC, section R406 An energy rating system must be utilized using approved and current software tools such as REM/Rate, Ekotrope, or EnergyGauge. A preliminary/projected ERI analysis must be submitted and shown to have an ERI index of less than or equal to 55. This is specific to climate zone 5 (found in 2015 IECC table R406.41. Contractor or Applicant Name: Amanda Robbins for Richmond American Homes pate: 9/28/18 Signatu ne:(720 ) 977-3872 2015 IRC Residential Energy Code Compliance Form V2 08/23/2017