Loading...
HomeMy WebLinkAbout705 Peregoy Farms Way - Applications/Single Family New - 09/20/2018COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES Fort of 281 N. College Ave. • Fort Collins, Co 80524 • Phone: 970-416-2740 www.fegov.com/building BUILDING PERMIT APPLICATION C�iDo�l-1 b ao (� APPLICATION NUMBER APPLICATION DATE Job Site Address 705 Peregoy Farms Way unit # PROPERTY OWNER INFO: (All owner information is required — it is not optional) Phone # 307-631-4816 Last name Lowder First Name Richard Middle Street address 5421 Sunset Drive city Cheyenne State 1NY zip 82009 CONTRACTOR INFO: Company Name Hammersmith Structures, LLC Contractor Phone # 970-381-7699 Lie Holder Name Chandler Souther Cityof Fort Collins License # D-663 Supervisor Cert # Mailing Address 201 Commerce Dr, Unit 2 City Fort Collins State CO Zip 80524 LEGAL INFO: Subdivision/PUD 8312001000 - Pateros Creek Filing # Lot # 14 Block # Lot Sq Ft 9,362 CONSTRUCTION INFO: Total Building Sq Ft (not including basement) 3,029 Total Garage Sq Ft 586.5 Residential Sq Ft 3,029 Comm'I Sq Ft n/a # of Stories 2 Bldg Height 32� # Dwelling Units 1 1 s' Floor Sq Ft 1,944 2nd Floor Sq Ft 1,085 31' Floor Sq Ft n/a Unfiished Bsmt Sq Ft n/a Finished Bsmt Sq Ft n/a # of Bedrooms 3 # of Full Baths 2 % Baths 1 '/: Baths 1 # of Fireplaces 1 Air Conditioning: Ye✓ No � Energy info: ( Circle appropriate choice) 1. ComCheck1:1 2. ResCheck w/Air Sealing 11 3. ResCheck wlBlower Door 4. Simulated Performance Alternative 5. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Door City of Fort Collins Stock Plan # List appropriate option #s UTILITIES INFO: Water Tap Size 3/4" Sewer Tap Size 4Metered: Yes ZNor Temp. Pedestal Yes[Z] No ❑ Type of Heat: Q Gas ❑Electric Electric Main Breaker Size (Residential only) 10150 Amp or Less 11 200 Amp DOther Value of Construction (including labor, material & profit) $ �C���� Q OD Description of Work: New 2-story sing a aml y detached residence with slab on grade founclation Contact Name & Phone # of JOBSITE SUPERVISOR: Chandler Souther 970-381-7699 Subcontractor Info: Electrical EJC Energy Mechanical Northern Colorado Air Framer n/a Roofing TKOs Roofing Concrete Solar n/a Other n/a Other Plumbing IPS Foundation Builders Fireplace Other Western Fireplace Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and Ci rt Co in's onan a d state laws regulating building construction. Applicant Signature .,� Print Name Chandler Souther Phone 970-381-7699 Distribution: White —Office Yellow —Applicant Pink —WWW/Stormwater rac�Lvkantrner6nir�Flr THUS APPLUC®Tu®NI fgTfpoaar _n -jR n ®®oY- FliMsra APPILla ®va®INI ®®TIR ZM cl-ores , cs•n Residential 2012 IRC Stock Plan Re -Review Checklist Company: Stock Plan # CONSTRUCTION DOCUMENTS: Construction Waste Management Plan 2014 Energy Compliance Form SPA/RESCheck showing 2012 IECC HVAC Load Calcs Mechanical System Design Submittal Form Correct code versions BUILDING: Floor Assembly Protection @ Bsmt/Crawl Ceiling Window well drainage Vinyl Siding not allowed Low VOC finishes Fenestration / Window u-Factor ENERGY: Method: Prescriptive / UA-RESCheck / SPA HVAC form info matches SPA form info Insulation on plans match forms Min R19 @ Eave over Ext. Wall Eave Baffles/Blocks Air Seal Rim / Spray foam R1S Rim Duct insulation: Attic / Crawl / Ext Wall / Garage VENT[ LATION/M ECHANICAL: Whole dwelling vent Natural Draft appliances HVAC Load Calcs (system & duct sizing) Mechanical Design Submittal form Exhaust vent to exterior for gas kitchen appliances Makeup air for exhaust vent >400cfm PLUMBING: IILow flow fixtures ELECTRICAL: Dark Sky fixtures - LZ1 RADON: Radon system marked and vented through roof REVIEW APPROVAL Date called applicant for corrections Date plans were approved NOTES: Plan Reviewer: CONSTRUCTION DOCUMENTS: Building Permit Application Stock Plan Application Site Plan Architectural Drawings (Structural Drawings Engirieere,d,Foundation LIFESAFETY:' Safety Glazing Location on property/Assumed property line requirements Egress Windows, r, Townhouse - Dbl 1-hr/Sgl 2-hr prop line wall Garage/Dwelling Separaticih Parapet at property line wall Stairs/Guardrails/Steps/Landings Duplex - Single 2-hr sep wall �} Rated wall due to property line FLOORS, WALLS & ROOF ' Roof classification)&'materials Wall weather resistive barrier Attic Acce'ss/Crawj space access Low VOC finishes Fenestratidn j, Window u-Factor ENERGY CODE: Prescriptive, ' UA.Method/R'ESCheck Simulated Performance Alternative Insulation on plans match forms HVAC form info matches SPA form info Attic/Crawlspace: Duct insulation, Poly on ground VENTILATION/MECHANICAL: Dryer Vent length 35' max Exhaust fans/Ventilation to habitable rooms Crawl/Bsmt under -floor ventilation, out/cond? Combustion Air PLUMBING: Freeze protection provided / Pan on wood floor Elevate water heaters in garage 18" Low flow fixtures ELECTRICAL: Smoke alarms / Carbon Monoxide alarms Arc -fault circuit FI Outlets (Bath, Kit, Garage, Bsmt) WP GFI at front & back door Lights outside exterior doors Dark Sky fixtures STRUCTURAL: Floor joists / Rafter spans / Roof framing / Wall framing Beams & Columns Wind load: 100mph Exposure B Braced walls / Shear walls RADON: Radon system marked and vented through.roof REVIEW APPROVAL Date called applicant for corrections Date plans were approved Plan Reviewer: Construction Waste Management Plan Energy Compliance Form SPA/RESCheck HVAC Load Calcs Mechanical System Design Submittal Form Correct code versions HVAC Load Calcs (system & duct sizing) Mechanical Design Submittal form Whole dwelling vent Natural Draft appliances