Loading...
HomeMy WebLinkAbout6026 Spindlebush Ln - Special Inspections/Fenestrations - 07/14/2017B SINCE 1986 BURGESS CONSTRUCTION CONSULTANTS INC. Plan Reviewer on Duty Building Services City of Fort Collins Community Development & Neighborhood Services RE: Window Inspection: 6026 Spindlebush Lane Date: 7/14/2017 I have inspected and passed the window inspection at 6026 Spindlebush Lane. The windows were installed using Installation Masters (AAMA) Method A-1. All sealants and proper flashing materials were applied to the proper location and in the proper sequence. The install also meets the requirements of the City of Fort Collins' 2012 IRC Amendment Section R703.8.1. Proper sill flashing and air sealing was completed. Sincerely, -~ ~ ~ 7479033 Robert Hutchinson Consultant, Energy Lead Burgess Construction Consultants, Inc. ICC Residential Combination Inspector #5256661 303-598-3819 Cell rhutchinson@burgess-inc.com TOGETHER ... WE BUILD EXCELLENCE SINGLE-FAMILY* MULTI-FAMILY* COMMERCIAL Energy • Consulting • Thermography • Water Intrusion • Phase Inspections • Code Compliance Dallas/Ft. Worth • Austin • San Antonio • Houston • Denver • Colorado Springs