Loading...
HomeMy WebLinkAbout3036 Dunbar Ave - Special Inspections/Engineering - 09/21/2018 (3)Gilbert Structural Engineering, LLC 3113 Meadowlark Ave Fort Collins, CO 80526 970.377.3100 September 21, 2018 � I Kestrel Builders 2307 Montadale Court Fort Collins, CO 80526 Project: Deck Addition ;/3036 Dunbar Avenue Units, 7,8 & 10 Fort Collins, CO GSE Project Number: 18-021 Don: In response to your request, I met with you at the referenced site to evaluate and comment on items of repair identified by the Inspector. 1. The Inspector's comment concerning blocking at the deck joists' exterior support is correct. Deck #7 & #8: 2. It is acceptable to notch the support beam for 3- 2x8s as shown in Photo 1. 3. The hanger attachment of the 2x12 to 2x8 ledger as shown in Photo 2 is acceptable. 3. It is acceptable to use Simpson hanger in lieu of Simpson A34 shown in design detail 2/S2. Deck #10: 4. The redwood 2x12 sistered to.the deck joist as shown in Photo 4 is a finish and need not be supported on its end. 5. A face mounted, hidden flange hanger for a triple 2x10 joist may be a Simpson HUCQ210-3-SDS. Sincerely, Glenn A Gilbert, PE No Text No Text