HomeMy WebLinkAbout320 Longleaf Ln - Disclosures/Blower Door Test - 12/29/2017BUILDING LEAKAGE TEST L&L Home Performance 401 N Link Ln Fort Collins, CO 80524 Phone: 970.221.3180 Fax: 970.568.0690 Email: llinsulationjh@gmail.com Website: www.ll-insulation.com Date of Test: 12/29/2017 Test File: Bldg 30 unit 4 Technician: Justin Heldenbrand Project Number: Customer: Capstone Cottage Builders Inc 224 N Lemay Ave Fort Collins, CO 80524 Building Address: Bldg 30 320 Longleaf Ln unit 4 Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 692 CFM50 ( +/- 9.8 %) (50 Pa = 0.2 w.c.) 2.56 ACH50 2. Leakage Area: 38.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 28.0 ( +/- 82.5 %) Exponent (n) = 0.820 ( +/- 0.222 ) Correlation Coefficient = 0.96526 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 45.6 CFM 0.17 ACH 9.1 CFM per person 2. Estimated Design Infiltration Rate: Winter: 75.9 CFM 0.28 ACH Summer: 47.6 CFM 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/29/2017 Test File: Bldg 30 unit 4 Building Information Volume 16240 Surface Area 2958 Floor Area 1680 Height 30 # of Bedrooms 4 # of Occupants 5 Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 43466-7-700 - Micromanometer Energy Conservatory DG700 43466 9/15/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/29/2017 Test File: Bldg 30 unit 4 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 46.0 66.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -7.0 n/a n/a -66.1 -63.6 194.2 826 889 5.5 Ring B -61.8 -59.3 168.3 769 828 4.0 Ring B -55.1 -52.7 133.3 685 738 2.2 Ring B -47.4 -45.0 103.3 604 650 2.5 Ring B -43.8 -41.4 81.8 538 579 -2.2 Ring B -39.0 -36.6 60.2 462 497 -7.1 Ring B -32.3 -29.9 35.1 353 381 -16.1 Ring B -20.3 -17.9 189.2 315 339 14.1 Ring C 2.2 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None - * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi-Point Test Standard. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/29/2017 Test File: Bldg 30 unit 4 Comments Building Performance Institute ID:5060608 (Building Analyst and Infiltration & Duct Leakage Certified) Connection to: Mechanical -50.0pa Garage NA