Loading...
HomeMy WebLinkAbout821 W Lake St - Disclosures/Blower Door Test - 06/20/2018 (11)BUILDING LEAKAGE TEST GS Services LTD 2000 S College Ave Suite 308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 6/20/2018 Technician: Nick Hiseler Test File: Brinkman Construction - 821 W Lake Street Project Unit 509 Number: - Type S - BDexp Customer: Brinkman Construction Phone: Fax: Building Address: 821 W Lake Street Unit 509 Fort Collins, CO Test Results at 50 Pascals: cfm50 Airflow 775 ( +/- 1.4 %) ACH50 cfm/ft² (Floor Area) 0.6409 cfm/ft² (Surface Area) 0.2029 Leakage Areas: 58.2 in² ( +/- 3.0 %) Canadian EqLA @ 10 Pa or 0.0152 in²/ft² Surface Area 25.9 in² ( +/- 5.1 %) LBL ELA @ 4 Pa or 0.0068 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 28.2 ( +/- 8.3 %) Exponent (n) = 0.847 ( +/- 0.023 ) Correlation Coefficient = 0.99942 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 90 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize _____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/20/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 509 - Type S - BDexp Building Information Volume (ft³) Surface Area: (ft²) 3818 Floor Area: (ft²) 1209 Height (ft) 10 Year of Construction Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Duct Blaster B 14375 1/23/2017 Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/20/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 509 - Type S - BDexp Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 62.0 Post-Test 70.0 62.0 Average 70.0 62.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -5.0 n/a n/a -65.2 -59.5 57.7 836 875 -2.6 Open -59.8 -54.0 50.8 785 821 -0.8 Open -54.9 -49.1 44.5 734 768 0.5 Open -49.6 -43.9 37.0 669 700 0.9 Open -44.7 -39.0 30.5 607 635 1.1 Open -40.3 -34.5 25.3 553 578 2.1 Open -34.7 -29.0 128.2 467 489 0.1 Ring 1 -30.3 -24.6 97.0 406 425 -0.1 Ring 1 -25.6 -19.9 68.1 340 355 0.1 Ring 1 -19.9 -14.2 37.3 251 262 -1.4 Ring 1 -6.4 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/20/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 509 - Type S - BDexp Comments None