Loading...
HomeMy WebLinkAbout821 W Lake St - Disclosures/Blower Door Test - 06/06/2018 (6)BUILDING LEAKAGE TEST GS Services LTD 2000 S College Ave Suite 308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 6/6/2018 Technician: Nick Hiseler Test File: Brinkman Construction - 821 W Lake Street Project Unit 420 Number: - Type E - BDexp Customer: Brinkman Construction Phone: Fax: Building Address: Stadium Apartments 821 W Lake Street Unit 420 Fort Collins, CO Test Results at 50 Pascals: cfm50 Airflow 545 ( +/- 1.2 %) ACH50 cfm/ft² (Floor Area) 0.4675 cfm/ft² (Surface Area) 0.1468 Leakage Areas: 48.7 in² ( +/- 2.8 %) Canadian EqLA @ 10 Pa or 0.0131 in²/ft² Surface Area 23.9 in² ( +/- 4.7 %) LBL ELA @ 4 Pa or 0.0064 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 30.3 ( +/- 7.5 %) Exponent (n) = 0.739 ( +/- 0.021 ) Correlation Coefficient = 0.99939 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 80 90 100 200 300 400 500 600 700 800 Building Leakage (cfm) Depressurize _____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/6/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 420 - Type E - BDexp Building Information Volume (ft³) Surface Area: (ft²) 3712 Floor Area: (ft²) 1166 Height (ft) 10 Year of Construction 2017 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Duct Blaster B 14375 1/23/2017 Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/6/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 420 - Type E - BDexp Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 87.0 88.0 Post-Test 87.0 88.0 Average 87.0 88.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.4 n/a n/a -65.1 -60.7 28.7 589 629 0.1 Open -59.5 -55.0 25.7 557 596 1.8 Open -54.9 -50.5 152.4 510 545 -0.7 Ring 1 -50.0 -45.5 128.5 468 500 -1.7 Ring 1 -43.2 -38.7 103.4 419 448 -0.7 Ring 1 -39.2 -34.8 89.0 389 415 -0.3 Ring 1 -35.0 -30.5 76.0 359 384 1.4 Ring 1 -30.8 -26.3 60.5 320 342 0.9 Ring 1 -23.3 -18.8 35.6 245 262 -1.3 Ring 1 -20.9 -16.4 203.4 225 241 0.6 Ring 2 -4.5 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/6/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 420 - Type E - BDexp Comments None