HomeMy WebLinkAbout821 W Lake St - Disclosures/Blower Door Test - 06/06/2018 (7)BUILDING LEAKAGE TEST GS Services LTD 2000 S College Ave Suite 308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 6/6/2018 Technician: Nick Hiseler Test File: Project Number: Customer: Brinkman Construction Phone: Fax: Building Address: Stadium Apartments 821 W Lake Street Unit 417 Fort Collins, CO Test Results at 50 Pascals: cfm50 Airflow 796 ( +/- 1.7 %) ACH50 cfm/ft² (Floor Area) 0.5246 cfm/ft² (Surface Area) 0.1710 Leakage Areas: 47.5 in² ( +/- 3.8 %) Canadian EqLA @ 10 Pa or 0.0102 in²/ft² Surface Area 18.5 in² ( +/- 6.4 %) LBL ELA @ 4 Pa or 0.0040 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 16.6 ( +/- 10.3 %) Exponent (n) = 0.990 ( +/- 0.029 ) Correlation Coefficient = 0.99936 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 60 70 80 100 90 200 300 400 500 600 700 800 1000 900 2000 Building Leakage (cfm) Depressurize _____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/6/2018 Test File: Building Information Volume (ft³) Surface Area: (ft²) 4654 Floor Area: (ft²) 1517 Height (ft) 10 Year of Construction 2017 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Duct Blaster B 14375 1/23/2017 Micromanometer Energy Conservatory DG700 19028-7 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/6/2018 Test File: Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 79.0 79.0 Post-Test 84.0 84.0 Average 81.5 81.5 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.5 n/a n/a -62.0 -61.0 60.4 856 965 -0.5 Open -56.2 -55.3 49.5 774 873 -0.7 Open -51.5 -50.5 42.4 716 807 0.3 Open -45.9 -44.9 244.8 647 729 1.9 Ring 1 -40.5 -39.5 193.0 574 647 2.6 Ring 1 -35.8 -34.8 137.0 483 545 -2.2 Ring 1 -32.3 -31.3 114.4 441 497 -0.8 Ring 1 -27.0 -26.1 77.3 362 408 -2.2 Ring 1 -18.9 -17.9 40.4 261 294 1.9 Ring 1 -16.1 -15.2 27.7 216 244 -0.2 Ring 1 -1.4 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/6/2018 Test File: Comments None