Loading...
HomeMy WebLinkAbout821 W Lake St - Disclosures/Blower Door Test - 06/20/2018 (9)BUILDING LEAKAGE TEST GS Services LTD 2000 S College Ave Suite 308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 6/20/2018 Technician: Nick Hiseler Test File: Brinkman Construction - 821 W Lake Street Project Unit 316 Number: - Type D - BDexp Customer: Brinkman Construction Phone: Fax: Building Address: 821 W Lake Street Unit 316 Fort Collins, CO Test Results at 50 Pascals: cfm50 Airflow 747 ( +/- 11.6 %) ACH50 cfm/ft² (Floor Area) 0.5947 cfm/ft² (Surface Area) 0.1890 Leakage Areas: 36.7 in² ( +/- 24.6 %) Canadian EqLA @ 10 Pa or 0.0093 in²/ft² Surface Area 12.8 in² ( +/- 41.7 %) LBL ELA @ 4 Pa or 0.0032 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 9.7 ( +/- 68.3 %) Exponent (n) = 1.111 ( +/- 0.194 ) Correlation Coefficient = 0.97782 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize _____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/20/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 316 - Type D - BDexp Building Information Volume (ft³) Surface Area: (ft²) 3952 Floor Area: (ft²) 1256 Height (ft) 10 Year of Construction Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Duct Blaster B 14375 1/23/2017 Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/20/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 316 - Type D - BDexp Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 66.0 Post-Test 70.0 66.0 Average 70.0 66.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.7 n/a n/a -61.7 -58.4 47.1 755 835 -6.0 Open -53.3 -50.1 40.8 703 777 3.8 Open -52.7 -49.5 33.1 633 700 -5.3 Open -44.4 -41.2 30.4 606 671 11.3 Open -37.4 -34.2 26.3 563 623 27.2 Open -36.7 -33.5 91.8 395 436 -8.8 Ring 1 -34.2 -31.0 76.8 361 399 -9.1 Ring 1 -29.8 -26.6 56.6 309 342 -7.6 Ring 1 -22.9 -19.7 31.6 231 255 -3.6 Ring 1 -16.7 -13.5 108.0 164 181 3.5 Ring 2 -4.7 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - n value (1.111) outside of acceptable limits (0,5 ≤ n ≤ 1). - Correlation coefficient (0.978) outside of acceptable limits. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/20/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 316 - Type D - BDexp Comments None