HomeMy WebLinkAbout821 W Lake St - Disclosures/Blower Door Test - 07/02/2018BUILDING LEAKAGE TEST GS Services LTD 2000 S College Ave Suite 308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 7/2/2018 Technician: Nick Hiseler Test File: Brinkman Construction - 821 W Lake Street Project Unit 111 Number: - Type M - BDexp Customer: Brinkman Construction Phone: Fax: Building Address: Stadium Apartments 821 W Lake Street Unit 111 Fort Collins, CO Test Results at 50 Pascals: cfm50 Airflow 996 ( +/- 1.3 %) ACH50 cfm/ft² (Floor Area) 0.8290 cfm/ft² (Surface Area) 0.2619 Leakage Areas: 99.9 in² ( +/- 2.6 %) Canadian EqLA @ 10 Pa or 0.0263 in²/ft² Surface Area 52.4 in² ( +/- 4.5 %) LBL ELA @ 4 Pa or 0.0138 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 73.1 ( +/- 7.3 %) Exponent (n) = 0.667 ( +/- 0.021 ) Correlation Coefficient = 0.99929 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize _____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/2/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 111 - Type M - BDexp Building Information Volume (ft³) Surface Area: (ft²) 3802 Floor Area: (ft²) 1201 Height (ft) 10 Year of Construction 2017 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 1/23/2017 Micromanometer Energy Conservatory DG700 42530-7 1/22/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/2/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 111 - Type M - BDexp Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 76.0 72.0 Post-Test 76.0 72.0 Average 76.0 72.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.1 n/a n/a -60.8 -58.8 37.0 1106 1139 2.6 Ring A -56.0 -54.0 31.2 1018 1048 -0.0 Ring A -52.0 -49.9 28.0 965 994 -0.0 Ring A -47.0 -45.0 222.3 883 910 -2.0 Ring B -41.3 -39.3 193.2 823 848 0.0 Ring B -37.0 -35.0 162.3 755 778 -0.9 Ring B -31.6 -29.6 129.1 674 695 -0.9 Ring B -25.7 -23.6 96.9 585 603 -0.2 Ring B -19.5 -17.5 66.0 484 498 0.9 Ring B -16.1 -14.1 48.9 417 429 0.5 Ring B -1.9 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/2/2018 Test File: Brinkman Construction - 821 W Lake Street Unit 111 - Type M - BDexp Comments None