Loading...
HomeMy WebLinkAbout2208 Shandy St - Disclosures/Blower Door Test - 07/18/2017BUILDING LEAKAGE TEST GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 7/18/2017 Test File: Hartford TV - 2208 Shandy St - BDma Technician: Nick Hiseler Project Number: Customer: Hartford Homes Building Address: 2208 Shandy St Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1005 CFM50 ( +/- 1.2 %) (50 Pa = 0.2 w.c.) 2.99 ACH50 2. Leakage Area: 55.3 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 125.7 ( +/- 9.5 %) Exponent (n) = 0.531 ( +/- 0.026 ) Correlation Coefficient = 0.99881 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/18/2017 Test File: Hartford TV - 2208 Shandy St - BDma Building Information Volume 20144 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/18/2017 Test File: Hartford TV - 2208 Shandy St - BDma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 80.0 80.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.3 n/a n/a -60.2 -60.0 37.4 1112 1120 1.2 Ring A -55.9 -55.7 33.0 1046 1054 -1.0 Ring A -49.6 -49.4 29.4 988 995 -0.3 Ring A -43.7 -43.5 239.5 916 923 -1.1 Ring B -36.7 -36.5 204.0 846 852 0.3 Ring B -31.2 -31.0 176.3 787 793 1.7 Ring B -25.0 -24.8 132.0 682 687 -0.7 Ring B -20.2 -20.0 106.1 612 617 -0.1 Ring B -0.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/18/2017 Test File: Hartford TV - 2208 Shandy St - BDma Comments House WRT Garage = -46.8 Pa