Loading...
HomeMy WebLinkAbout3526 Big Ben Dr - Disclosures/Blower Door Test - 04/23/2018 (2)BUILDING LEAKAGE TEST GS Services, LTD 2000 S. College Avenue Ste. 308 Fort Collins, CO 80525 Date of Test: 4/23/2018 Test File: Hartford Homes - 3526 Big Ben Drive - Unit C - BDma Technician: Project Number: Customer: Hartford Homes Building Address: 3526 Big BenDrive Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1107 CFM50 ( +/- 2.1 %) (50 Pa = 0.2 w.c.) 2.98 ACH50 2. Leakage Area: 60.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 30.3 ( +/- 17.5 %) Exponent (n) = 0.920 ( +/- 0.048 ) Correlation Coefficient = 0.99830 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 50.8 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 74.2 CFM 0.20 ACH Summer: 54.5 CFM 0.15 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/23/2018 Test File: Hartford Homes - 3526 Big Ben Drive - Unit C - BDma Building Information Volume 22260 Surface Area Floor Area 2410 Height 9 # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/23/2018 Test File: Hartford Homes - 3526 Big Ben Drive - Unit C - BDma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 72.0 59.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.2 n/a n/a -60.3 -60.1 47.4 1248 1306 -0.5 Ring A -55.1 -55.0 39.9 1147 1200 -0.7 Ring A -50.0 -49.9 32.8 1042 1090 -1.3 Ring A -45.6 -45.5 28.2 968 1013 -0.2 Ring A -40.1 -40.0 221.9 882 923 2.4 Ring B -35.4 -35.3 164.7 761 796 -0.9 Ring B -30.2 -30.1 131.3 680 711 2.6 Ring B -25.9 -25.8 97.2 586 613 1.9 Ring B -20.7 -20.6 57.6 452 473 -3.3 Ring B -0.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4/23/2018 Test File: Hartford Homes - 3526 Big Ben Drive - Unit C - BDma Comments hwrt garage = -45.5 pa