HomeMy WebLinkAbout3057 County Fair Ln - Disclosures/Blower Door Test - 06/12/2018 (2)BUILDING LEAKAGE TEST Date of Test: 6/12/2018 Test File: 3057 County Fair Lane 6 Tectite Technician: Matthew Anthony Project Number: Customer: Building Address: 3057 County Fair Lane 6 Ft Collins, CO 80528 Test Results 1. Airflow at 50 Pascals: 812 CFM50 ( +/- 5.3 %) (50 Pa = 0.2 w.c.) 2.83 ACH50 2. Leakage Area: 44.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 33.4 ( +/- 35.3 %) Exponent (n) = 0.816 ( +/- 0.099 ) Correlation Coefficient = 0.99275 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 48.7 CFM 0.17 ACH 12.2 CFM per person 2. Estimated Design Infiltration Rate: Winter: 89.0 CFM 0.31 ACH Summer: 55.9 CFM 0.19 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/12/2018 Test File: 3057 County Fair Lane 6 Tectite Building Information Volume 17236 Surface Area 3030 Floor Area 1622 Height 22 # of Bedrooms 3 # of Occupants 4 Year of Construction 2018 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 30115 Default Micromanometer Energy Conservatory DG700 13013-7 10/25/2016 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/12/2018 Test File: 3057 County Fair Lane 6 Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 68.0 71.0 4920.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -5.4 n/a n/a -65.2 -58.2 222.4 883 941 2.4 Ring B -59.3 -52.3 185.8 808 861 2.2 Ring B -51.6 -44.5 147.3 720 767 3.9 Ring B -49.3 -42.2 103.7 605 645 -8.9 Ring B -41.9 -34.9 86.4 553 589 -2.7 Ring B -36.2 -29.1 70.4 499 532 1.8 Ring B -30.6 -23.5 49.0 417 444 1.3 Ring B -23.5 -16.4 182.0 309 329 0.6 Ring C -8.7 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/12/2018 Test File: 3057 County Fair Lane 6 Tectite Comments House to garage connection: target of 45Pa / tested at 46Pa. You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)