Loading...
HomeMy WebLinkAbout3039 County Fair Ln - Disclosures/Blower Door Test - 09/10/2018BUILDING LEAKAGE TEST Date of Test: 9/10/2018 Test File: 3039 County Fair Lane 4 The Park at Fossil Ridge TECTITE Technician: Zach Kimbrough - EnergyLogic Project Number: 50801 Customer: The Park at Fossil Ridge, LLC Building Address: 3039 County Fair Lane 3 Ft Collins , CO 80528 Test Results 1. Airflow at 50 Pascals: 884 CFM50 ( +/- 1.0 %) (50 Pa = 0.2 w.c.) 2.93 ACH50 2. Leakage Area: 48.6 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 156.5 ( +/- 6.9 %) Exponent (n) = 0.443 ( +/- 0.019 ) Correlation Coefficient = 0.99907 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 51.6 CFM 0.17 ACH 12.9 CFM per person 2. Estimated Design Infiltration Rate: Winter: 97.0 CFM 0.32 ACH Summer: 60.9 CFM 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/10/2018 Test File: 3039 County Fair Lane 4 The Park at Fossil Ridge TECTITE Building Information Volume 18125.83 Surface Area Floor Area 1643.0 Height 20 # of Bedrooms 3 # of Occupants 4 Year of Construction 2018 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/10/2018 Test File: 3039 County Fair Lane 4 The Park at Fossil Ridge TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 71.0 84.0 4900.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 27.9 963 961 0.2 Ring A -54.0 -54.0 25.2 916 914 -0.1 Ring A -48.0 -48.0 217.8 874 872 0.4 Ring B -42.0 -42.0 187.8 812 810 -1.0 Ring B -36.0 -36.0 170.0 773 771 0.9 Ring B -30.0 -30.0 142.8 709 707 0.3 Ring B -24.0 -24.0 113.2 632 630 -1.3 Ring B -18.0 -18.0 91.3 568 567 0.7 Ring B 0.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None - * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi-Point Test Standard. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9/10/2018 Test File: 3039 County Fair Lane 4 The Park at Fossil Ridge TECTITE Comments Garage: -50 PA Mech: -50 PA