HomeMy WebLinkAbout1179 Cloverdale Dr - Disclosures/Blower Door Test - 01/05/2018 (5)BUILDING LEAKAGE TEST L&L Home Performance 401 N Link Ln Fort Collins, CO 80524 Phone: 970.221.3180 Fax: 970.568.0690 Email: llinsulationjh@gmail.com Website: www.ll-insulation.com Date of Test: 1/5/2018 Test File: Bldg 29 unit 2 Technician: Justin Heldenbrand Project Number: Customer: Capstone Cottage Builders Inc 224 N Lemay Ave Fort Collins, CO 80524 Building Address: Bldg 29 1179 Cloverdale Dr unit 2 Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 778 CFM50 ( +/- 0.9 %) (50 Pa = 0.2 w.c.) 2.87 ACH50 2. Leakage Area: 42.8 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 25.8 ( +/- 6.3 %) Exponent (n) = 0.871 ( +/- 0.017 ) Correlation Coefficient = 0.99980 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 51.2 CFM 0.19 ACH 10.2 CFM per person 2. Estimated Design Infiltration Rate: Winter: 85.3 CFM 0.32 ACH Summer: 53.5 CFM 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 1/5/2018 Test File: Bldg 29 unit 2 Building Information Volume 16240 Surface Area 2958 Floor Area 1680 Height 30 # of Bedrooms 4 # of Occupants 5 Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 43466-7-700 - Micromanometer Energy Conservatory DG700 43466 9/15/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 1/5/2018 Test File: Bldg 29 unit 2 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 38.0 50.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -12.5 n/a n/a -72.4 -59.5 215.7 870 911 0.7 Ring B -66.7 -53.7 178.5 792 829 0.2 Ring B -60.4 -47.4 144.7 714 747 0.6 Ring B -54.5 -41.5 110.8 625 655 -1.0 Ring B -48.4 -35.5 85.3 549 575 -0.3 Ring B -42.6 -29.7 61.6 467 489 -0.9 Ring B -36.6 -23.7 42.0 386 405 -0.2 Ring B -30.8 -17.9 178.7 306 320 1.0 Ring C -13.4 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 1/5/2018 Test File: Bldg 29 unit 2 Comments Building Performance Institute ID:5060608 (Building Analyst and Infiltration & Duct Leakage Certified) Connection to: Mechanical -50.0pa Garage NA