Loading...
HomeMy WebLinkAbout2357 Adobe Dr - Disclosures/Blower Door Test - 08/17/2017BUILDING LEAKAGE TEST Date of Test: 8/17/2017 Test File: 2357 Adobe Dr LC Homes TECTITE Technician: Zach Kimbrough - EnergyLogic Project Number: 47434 Customer: LC Home Building Address: 2357 Adobe Dr Ft Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 922 CFM50 ( +/- 1.1 %) (50 Pa = 0.2 w.c.) 2.80 ACH50 2. Leakage Area: 50.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 47.9 ( +/- 8.3 %) Exponent (n) = 0.756 ( +/- 0.023 ) Correlation Coefficient = 0.99954 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 53.8 CFM 0.16 ACH 10.8 CFM per person 2. Estimated Design Infiltration Rate: Winter: 101.1 CFM 0.31 ACH Summer: 63.4 CFM 0.19 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/17/2017 Test File: 2357 Adobe Dr LC Homes TECTITE Building Information Volume 19722.53 Surface Area Floor Area 2246.3 Height 20 # of Bedrooms 4 # of Occupants 5 Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 26986-7 8/2/2010 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/17/2017 Test File: 2357 Adobe Dr LC Homes TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 72.0 85.0 8200.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.7 n/a n/a -62.4 -60.5 28.3 971 1083 1.7 Ring A -55.5 -53.6 212.1 862 962 -1.0 Ring B -49.6 -47.7 178.7 792 884 -0.6 Ring B -43.2 -41.3 145.3 715 798 -0.1 Ring B -37.7 -35.8 117.5 644 718 0.2 Ring B -32.6 -30.7 90.3 565 630 -1.2 Ring B -26.3 -24.4 66.0 484 540 0.7 Ring B -20.1 -18.2 42.0 387 431 0.3 Ring B -2.1 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/17/2017 Test File: 2357 Adobe Dr LC Homes TECTITE Comments Garage: -45 PA Mech: -50 PA