Loading...
HomeMy WebLinkAbout2330 Adobe Dr - Disclosures/Blower Door Test - 08/13/2018BUILDING LEAKAGE TEST Date of Test: 8/13/2018 Test File: 2330 Adobe Dr 2.15ACH 8.13.18 Technician: Greydon Studer EnergyLogic Project Number: Customer: Building Address: 2330 Adobe Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 987 CFM50 ( +/- 2.1 %) (50 Pa = 0.2 w.c.) 2.15 ACH50 2. Leakage Area: 54.3 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 59.1 ( +/- 19.8 %) Exponent (n) = 0.719 ( +/- 0.053 ) Correlation Coefficient = 0.99666 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/13/2018 Test File: 2330 Adobe Dr 2.15ACH 8.13.18 Building Information Volume 27561 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction 2018 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/13/2018 Test File: 2330 Adobe Dr 2.15ACH 8.13.18 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 69.0 70.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.5 n/a n/a -72.0 -69.4 45.6 1224 1277 2.3 Ring A -66.0 -63.4 35.3 1080 1127 -3.7 Ring A -60.0 -57.4 32.6 1040 1085 -0.4 Ring A -54.0 -51.4 27.9 963 1005 -0.1 Ring A -48.0 -45.4 240.5 918 958 4.1 Ring B -42.0 -39.4 172.2 778 812 -2.3 Ring B -36.0 -33.4 142.8 709 740 0.3 Ring B -30.0 -27.4 109.3 621 648 1.3 Ring B -24.0 -21.4 72.9 508 530 -1.1 Ring B -2.7 n/a n/a Time Averaging Period: 5 Deviations from Standard RESNET Multi-Point Test - Test Parameters - The Time Averaging Period is less than 10 seconds. You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/13/2018 Test File: 2330 Adobe Dr 2.15ACH 8.13.18 Comments CAZ -48 House to Garage -48 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)