Loading...
HomeMy WebLinkAbout729 S Shields St - Special Inspections/Engineering - 08/14/2018Structural Closeout Letter Page 1 of 2 KL&A, Inc. 421 East 4th Street Loveland, Colorado 80537 Telephone: (970) 667-2426 August 14, 2018 Ryan Espinera Hug and Associates, LLC 5250 Avalon Blvd. Alpharetta, GA 30009 Re: Kappa Kappa Gamma Structural Closeout Dear Mr. Espinera: The purpose of this letter is to summarize the activities of KL&A, Inc. as the consulting structural engineer on the Renovations and Additions for Kappa Kappa Gamma Sorority located in Fort Collins, Colorado. KL&A performed calculations and prepared drawings for the construction of the structure of the building including spread footing foundations, slab on grade, CMU wall framing, structural steel framing and wood framing. In addition, we reviewed submittals for the concrete mix design, reinforcing steel, masonry, structural steel, structural composite lumber, and pre-manufactured wood roof trusses. A representative of KL&A also performed periodic site visits to observe the project under construction for general compliance with the structural contract documents and responded to construction questions from the field. These observations were not continuous or exhaustive, therefore all conditions may not have been observed. In addition to the structural observations we performed, Earth Engineering Consultant’s, EEC was retained by the owner to perform special inspection as required by the contract documents and the building code. It is our understanding that EEC provided structural special inspection for subgrade preparation, structural concrete (reinforcing steel placement and concrete testing), concrete masonry unit wall construction, cold formed steel wall framing, and structural steel. To the best of our knowledge, KL&A was aware of discrepancies reported by the testing agency and the reported discrepancies have been resolved. Based on our observations and experience, to the best of our knowledge, the structure of Kappa Kappa Gamma was constructed in general conformance with the structural contract documents and is, in our opinion, substantially in conformance with the structural provisions of the 2012 International Building Code and local code amendments by the city of Fort Collins. Structural Closeout Letter Page 2 of 2 If you have any questions, please feel free to call. Sincerely, Prepared By: Sarah Early Reviewed By: Christopher S. Kendall, P.E. Structural Designer Principal, EOR CC: Elder Construction 08/14/2018