Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6315 Morning Light Pl - Disclosures/Final Energy - 07/25/2017
Air Leakage Property Toll Brothers 6315 Morning Light Place Fort Collins, CO 80528 Weather:Ft. Collins, CO Valmont Walkout base Western Slider 6315 Morning Light Place.blg Organization Burgess, Inc. - BCCI 303-300-4527 Barrett Hendricks Builder Toll Brothers Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 07/25/2017 Rating No:03091708JV Rater ID:6761425 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.13 0.10 ACH @ 50 Pascals 1.85 1.85 CFM @ 25 Pascals 1287 1287 CFM @ 50 Pascals 2020 2020 Eff. Leakage Area (sq.in) 110.9 110.9 Specific Leakage Area 0.00013 0.00013 ELA/100 sf shell (sq.in) 0.88 0.88 CFM50/sf shell 0.16 0.16 Leakage to Outside Units Ducts up CFM @ 25 Pascals 0 45 CFM25 / CFMfan 0.0000 0.0297 CFM25 / CFA 0.0000 0.0216 CFM per Std 152 N/A N/A CFM per Std 152 / CFA N/A N/A CFM @ 50 Pascals 0 71 Eff. Leakage Area (sq.in) 0.00 3.88 Thermal Efficiency N/A N/A Total Duct Leakage Units CFM25/CFA CFM25/CFA Total Duct Leakage 0.0222 0.0216 Mechanical Exhaust Only ASHRAE ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate (cfm) 125 99 125 Hours/Day 24.0 24.0 24.0 Fan Watts 11.3 Cooling Ventilation Natural Ventilation Component Loads Property Toll Brothers 6315 Morning Light Place Fort Collins, CO 80528 Weather:Ft. Collins, CO Valmont Walkout base Western Slider Organization Burgess, Inc. - BCCI 303-300-4527 Barrett Hendricks Builder Toll Brothers REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 07/25/2017 Rating No:03091708JV ID:6761425 Page 1 of 2 Heating Season MMBtu/yr Ceilings/Roofs 11.4 Rim/Band Joists 4.0 Above Grade Walls 40.1 Foundation Walls 8.5 Doors 2.2 Windows/Skylights 23.9 Floors 3.1 Crawl Space/Unht Bsmt 0.0 Slab Floors 12.3 Infiltration 11.3 Mechanical Ventilation 20.7 Ducts 4.8 Active Solar 0.0 Sunspace 0.0 Internal Gains -22.2 Total 119.8 Heating Season (MMBtu/yr) Ceilings/Roofs Rim/Band Joists Above Grade Walls Foundation Walls Doors Windows/Skylights Floors Crawl Space/Unht Bsmt Slab Floors Infiltration Mechanical Ventilation Ducts Active Solar Sunspace Internal Gains 0.00 10.00 20.00 30.00 Component Loads Property Toll Brothers 6315 Morning Light Place Fort Collins, CO 80528 Weather:Ft. Collins, CO Valmont Walkout base Western Slider Organization Burgess, Inc. - BCCI 303-300-4527 Barrett Hendricks Builder Toll Brothers REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 07/25/2017 Rating No:03091708JV ID:6761425 Page 2 of 2 Cooling Season MMBtu/yr Ceilings/Roofs 0.6 Rim/Band Joists -0.3 Above Grade Walls 0.2 Foundation Walls -0.7 Doors -0.2 Windows/Skylights 21.7 Floors -0.2 Crawl Space/Unht Bsmt 0.0 Slab Floors -2.0 Infiltration -0.4 Mechanical Ventilation -1.3 Ducts 1.6 Active Solar 0.0 Sunspace 0.0 Internal Gains 15.3 Whole House Ventilation -7.8 Total 26.5 Cooling Season (MMBtu/yr) Ceilings/Roofs Rim/Band Joists Above Grade Walls Foundation Walls Doors Windows/Skylights Floors Crawl Space/Unht Bsmt Slab Floors Infiltration Mechanical Ventilation Ducts Active Solar Sunspace Internal Gains Whole House Ventilation 0.00 5.00 2005 EPACT Energy Efficient Home Tax Credit ( 13-001 ) Property Toll Brothers 6315 Morning Light Place Fort Collins, CO 80528 Weather:Ft. Collins, CO Valmont Walkout base Western Slider 6315 Morning Light Place.blg Organization Burgess, Inc. - BCCI 303-300-4527 Barrett Hendricks Builder Toll Brothers REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 07/25/2017 Rating No:03091708JV Rater ID:6761425 Registry ID: 587943593 This home DOES NOT meet the requirements for the residential energy efficiency tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005 extended to December 31, 2016. Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete. Normalized, Modified End-Use Loads (MMBtu/yr) 2006 IECC 50% Target As Designed Heating 75.7 80.3 Envelope Loads (MMBtu/yr) 2006 IECC 90% Target As Designed Heating 136.2 108.6 Building Features Ceiling Flat R-38.0 Exposed Floor R-38.0 Cooling 12.3 17.7 Cooling 22.1 20.4 Sealed Attic NA Slab R-0.0 Total 88.0 98.0 Total 158.3 129.0 Vaulted Ceiling NA Duct R-8.0 Above Grade Walls R-21.0 Window U-Value: 0.300, SHGC: 0.320 Foundation Walls R-19.0 Cooling Air conditioner, Electric, 13.0 SEER. Heating Fuel-fired air distribution, Natural gas, 80.0 AFUE. Name Barrett Hendricks Date 25 July 2017 Company Burgess, Inc. - BCCI Address 9033 East Easter Place Ste200, Cenntenial, CO 80112 Signature 2012 IECC Energy Cost Compliance Property Toll Brothers 6315 Morning Light Place Fort Collins, CO 80528 Weather:Ft. Collins, CO Valmont Walkout base Western Slider Organization Burgess, Inc. - BCCI 303-300-4527 Barrett Hendricks Builder Toll Brothers HERS Confirmed 07/25/2017 Rating No:03091708JV Rater ID:6761425 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Annual Energy Cost $/yr 2012 IECC As Designed Heating 1060 1035 Cooling 355 366 Water Heating 141 141 SubTotal - Used to Determine Compliance 1556 1542 Lights & Appliances 1233 1108 Photovoltaics -0 -0 Service Charge 240 240 Total 3029 2889 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1.2) PASSES Duct Leakage (Section 403.2.2) PASSES Mechanical Ventilation (Section 403.5) PASSES Mechanical Ventilation Fan Efficacy (Section 403.5.1) PASSES Mandatory Requirements Check Box (2012 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 0.9%. Name Barrett Hendricks Signature Organization Burgess, Inc. - BCCI Date 25 July 2017 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 6315 Morning Light Place, Fort Collins, CO by Toll Brothers exceeds the minimum requirements for the 2012 International Energy Conservation Code The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Building Features Ceiling Flat R-38.0 Duct R-8.0 Sealed Attic: NA Duct Leakage to Outside: 0.00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage: 90.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration: Htg: 2020 Clg: 2020 CFM50 Foundation Walls R-19.0 Window U-Value: 0.300, SHGC: 0.320 Exposed Floor R-38.0 Heating Fuel-fired air distribution, Natural gas, 80.0 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Instant water heater, Natural gas, 0.82 EF, 0.0 Gal. Name Barrett Hendricks Signature Organization Burgess, Inc. - BCCI Date 25 July 2017 2012 IECC Certificate 6315 Morning Light Place, Fort Collins, CO 80528 Building Envelope Insulation Ceiling R-38.0 Above Grade Walls R-21.0 Foundation Walls R-19.0 Exposed Floor R-38.0 Slab R-0.0 Edge, R-0.0 Under Infiltration Htg: 2020 Clg: 2020 CFM50 Duct R-8.0 Total Duct Leakage 90.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window 0.300 0.320 Mechanical Equipment HEAT: Fuel-fired air distribution, Natural gas, 80.0 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Instant water heater, Natural gas, 0.82 EF, 0.0 Gal. Builder or Design Professional Signature REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 Home Energy Rating Certificate HERS Index: 59 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. General Information Conditioned Area 6145 sq. ft. House Type Single-family detached Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Building Shell Features Ceiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 Under Lights and Appliance Features Percent Interior Lighting 100.00 Range/Oven Fuel Electric Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 133.8 $873 35% Criteria This home meets or exceeds the minimum criteria for the following: 2006 International Energy Conservation Code Conditioned Volume 65461 cubic ft. Foundation More than one type Heating: Fuel-fired air distribution, Natural gas, 80.0 AFUE. Sealed Attic NA Exposed Floor R-38.0 Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric BurgessConstructionConsultantsInc Cooling 6.1 $178 7% 2009 International Energy Conservation Code Bedrooms 4 Cooling: Air conditioner, Electric, 13.0 SEER. Vaulted Ceiling NA Window Type U-Value: 0.300, SHGC: 0.320 Refrigerator (kWh/yr) 475 Clothes Dryer CEF 2.62 101 W Renner Rd, Suite 400 Hot Water 17.4 $104 4% 2012 International Energy Conservation Code Duct Leakage to Outside 45.00 CFM25. Above Grade Walls R-21.0 Infiltration Rate Htg: 2020 Clg: 2020 CFM50 Dishwasher Energy Factor 0.68 Ceiling Fan (cfm/Watt) 0.00 Richardson, Texas 75082 Lights/Appliances 37.8 $1108 44% 2015 International Energy Conservation Code Ventilation System Exhaust Only: 125 cfm, 11.3 watts. Foundation Walls R-19.0 Method Blower door test 214-888-7260 Photovoltaics -0.0 $-0 -0% Programmable Thermostat Heat=Yes; Cool=Yes 214-888-7261 Service Charges $240 10% Total 195.1 $2503 100% Property HERS Toll Brothers Rating Type: Confirmed Certified Energy Rater: Barrett Hendricks 6315 Morning Light Place Rating Date: 07/25/2017 Rating Number: 03091708JV Fort Collins, CO 80528 Registry ID: 587943593 HERS PERFORMANCE REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. ENERGY RATING CERTIFICATE 59 Estimated Annual Energy Cost Heating Cooling Water Heating Lights & App Photovoltaics Service Charge Total 0 500 1000 1500 2000 2500 3000 $/yr 178 104 0 240 873 1,108 2,503 Estimated Annual Energy Consumption Heating Cooling Water Heating Lights & App Photovoltaics Total 0.0 50.0 100.0 150.0 200.0 MMBtu/yr 6.0 17.0 0.0 38.0 134.0 195.0 Address 6315 Morning Light Place Fort Collins, CO 80528 House Type Single-family detached Cond. Area 6145 sq. ft. Rating No. 03091708JV Issue Date July 25, 2017 Certification Inspected and Tested Annual Estimates* Electric(kWh): 13763 Natural gas(Therms): 1481 C02 emissions(Tons): 21 Annual Savings**: $2252 * Based on standard operating conditions ** Based on a HERS 130 Index Home BurgessConstructionConsultantsInc 101 W Renner Rd, Suite 400 Certified Rater Barrett Hendricks Rater ID 6761425 Registry ID 587943593 Rating Date 07/25/2017 10.00 15.00 20.00 25.00 -5.00 -10.00 MMBtu/yr 0.60 -0.30 0.20 -0.70 -0.20 -0.20 0.00 -2.00 -0.40 -1.30 0.00 0.00 -7.80 1.60 15.30 21.70 40.00 50.00 -10.00 -20.00 -30.00 MMBtu/yr 2.20 0.00 0.00 0.00 -22.20 4.00 3.10 4.80 8.50 11.40 12.30 11.30 20.70 23.90 40.10