6026 Spindlebush Ln - Disclosures/Final Energy - 07/14/2017
AIR LEAKAGE REPORT Date: July 14, 2017 Rating No.: 07112017093CRB Building Name: Bancroft Rating Org.: Burgess Inc - BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6026 Spindlebush Lane Rater's Name: Barrett Hendricks Address: Fort Collins, CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6026 Spindlebush Lane.blg Rating Date: 07/14/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Whole House Infiltration Blower door test Heating Cooling Natural ACH: 0.10 0.07 ACH @ 50 Pascals: 2.12 2.12 CFM @ 25 Pascals: 869 869 CFM @ 50 Pascals: 1363 1363 Eff. Leakage Area: [sq.in] 74.8 74.8 Specific Leakage Area: 0.00015 0.00015 ELA/100 sf shell: [sq.in] 0.82 0.82 Duct Leakage Leakage to Outside Units Ducts CFM @ 25 Pascals: 0 CFM25 / CFMfan: 0.0000 CFM25 / CFA: 0.0000 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 0 Eff. Leakage Area: [sq.in] 0.00 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0398 Ventilation Mechanical: Exhaust Only ASHRAE ASHRAE Sensible Recovery Eff. (%): 0.0 62.2-2010 62.2-2013 Total Recovery Eff. (%): 0.0 Rate (cfm): 91 64 91 Hours/Day: 24.0 24 24 Fan Watts: 11.3 Cooling Ventilation: Natural Ventilation Regarding ASHRAE 62.2 Ventilation Compliance The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. COMPONENT LOAD SUMMARY Date: July 14, 2017 Rating No.: 07112017093CRB Building Name: Bancroft Rating Org.: Burgess Inc - BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6026 Spindlebush Lane Rater's Name: Barrett Hendricks Address: Fort Collins, CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6026 Spindlebush Lane.blg Rating Date: 07/14/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Bancroft HEATING SEASON (MMBtu/yr) Ceilings/Roofs 11.3 Rim/Band Joists 2.0 Above Grade Walls 16.2 Foundation Walls 10.4 Doors 1.0 Windows/Skylights 13.5 Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors 9.6 Infiltration 3.2 Mechanical Ventilation 15.0 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -17.1 Total 65.1 COMPONENT LOAD SUMMARY Bancroft Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Bancroft COOLING SEASON (MMBtu/yr) Ceilings/Roofs 0.6 Rim/Band Joists -0.2 Above Grade Walls -0.0 Foundation Walls -0.9 Doors -0.1 Windows/Skylights 9.5 Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors -3.1 Infiltration -0.1 Mechanical Ventilation -0.9 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains 11.4 Whole House Ventilation -4.3 Total 12.0 2005 EPACT ENERGY EFFICIENT HOME TAX CREDIT ( 13-001 ) Date: July 14, 2017 Rating No.: 07112017093CRB Building Name: Bancroft Rating Org.: Burgess Inc - BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6026 Spindlebush Lane Rater's Name: Barrett Hendricks Address: Fort Collins, CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6026 Spindlebush Lane.blg Rating Date: 07/14/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Normalized, Modified End-Use Loads (MMBtu/year) 2006 IECC 50% Target As Designed Heating: 38.0 38.5 Cooling: 5.9 7.7 Total: 44.0 46.1 Envelope Loads (MMBtu/year) 2006 IECC 90% Target As Designed Heating: 68.4 61.1 Cooling: 10.7 9.4 Total: 79.1 70.5 This home DOES NOT meet the requirements for the residential energy efficiency tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005 extended to December 31, 2016. Building Features Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Duct: R-8.0 Vaulted Ceiling: NA Window: U-Value: 0.300, SHGC: 0.320 Above Grade Walls: R-23.0 Heating Fuel-fired air distribution, Natural gas, 92.0 AFUE. Foundation Walls: R-19.0 Cooling Air conditioner, Electric, 13.0 SEER. Exposed Floor: NA Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete. Name: Barrett Hendricks Signature: Company: Burgess Inc - BCCI Date: 07/14/2017 Address: 9033 E. Easter Place, Ste. 200, Centennial, CO 80112 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: July 14, 2017 Rating No.: 07112017093CRB Building Name: Bancroft Rating Org.: Burgess Inc - BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6026 Spindlebush Lane Rater's Name: Barrett Hendricks Address: Fort Collins, CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6026 Spindlebush Lane.blg Rating Date: 07/14/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2012 IECC As Designed Heating: 537 528 Cooling: 173 163 Water Heating: 128 128 SubTotal - Used to Determine Compliance: 838 819 Lights & Appliances: 825 750 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 1903 1809 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.300 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 2.4%. Name: Barrett Hendricks Signature: Organization: Burgess Inc - BCCI Date: July 14, 2017 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 64.0 kBtuh, 92.0 AFUE. Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.63 EF. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Bancroft Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Window-to-Floor Area Ratio: 0.14 Blower door test: Htg: 1363 Clg: 1363 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 6026 Spindlebush Lane, Fort Collins, CO by Toll Brothers exceeds the minimum requirements for the 2012 International Energy Conservation Code Building Features Ceiling Flat: R-38.0 Duct Leakage to Outside: 0.00 CFM @ 25 Pascals Sealed Attic: NA Total Duct Leakage: 137.00 CFM @ 25 Pascals Vaulted Ceiling: NA Infiltration: Htg: 1363 Clg: 1363 CFM50 Above Grade Walls: R-23.0 Window: U-Value: 0.300, SHGC: 0.320 Foundation Walls: R-19.0 Heating Fuel-fired air distribution, Natural gas, 92.0 AFUE. Exposed Floor: NA Cooling Air conditioner, Electric, 13.0 SEER. Slab: R-0.0 Edge, R-0.0 Under Water Heating Conventional, Natural gas, 0.63 EF, 50.0 Gal. Duct: NA 07/14/2017 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Name: Barrett Hendricks Signature: Organization: Burgess Inc - BCCI Date: July 14, 2017 The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 2012 IECC Certificate 6026 Spindlebush Lane, Fort Collins, CO 80528 Building Envelope Insulation Ceiling: R-38.0 Above Grade Walls: R-23.0 Foundation Walls: R-19.0 Exposed Floor: NA Slab: R-0.0 Edge, R-0.0 Under Infiltration: Htg: 1363 Clg: 1363 CFM50 Duct: NA Total Duct Leakage: 137.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window: 0.300 0.320 Mechanical Equipment HEAT: Fuel-fired air distribution, Natural gas, 92.0 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Natural gas, 0.63 EF, 50.0 Gal. Builder or Design Professional Signature _________________________________________ REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 Bancroft 6026 Spindlebush Lane Fort Collins, CO 80528 5 Stars Plus Confirmed Registry ID: 035991789 Rating Number: 07112017093CRB Certified Energy Rater: Barrett Hendricks Rating Date: 07/14/2017 Rating Ordered For: Toll Brothers Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 65.9 $426 26% Cooling 2.9 $85 5% Hot Water 19.4 $117 7% Lights/Appliances 25.6 $750 46% Photovoltaics -0.0 $-0 -0% Service Charges $240 15% Total 113.8 $1618 100% This home meets or exceeds the minimum criteria for all of the following: 2009 International Energy Conservation Code 2012 International Energy Conservation Code Burgess Construction Consultants 101 W. Renner Road, Suite 400 Richardson, TX 75082 214-888-7300 214-888-7266 Uniform Energy Rating System 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less Energy Efficient HERS Index: 62 Efficient Home Comparison: 38% Better General Information Conditioned Area: 3440 sq. ft. HouseType: Single-family detached Conditioned Volume: 38565 cubic ft. Foundation: More than one type Bedrooms: 3 Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 92.0 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.63 EF, 50.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 91 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: NA Vaulted Ceiling: NA Window Type: U-Value: 0.300, SHGC: 0.320 Above Grade Walls: R-23.0 Infiltration Rate: Htg: 1363 Clg: 1363 CFM50 Foundation Walls: R-19.0 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 100.00 Range/Oven Fuel: Electric Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 475.00 Clothes Dryer CEF: 2.32 Dishwasher (kWh/yr): 260.00 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. HERS PERFORMANCE ENERGY RATING CERTIFICATE 0 500 1000 1500 2000 Heating Cooling Water Heating Lights & App Photovoltaics Service Charge Total $/yr Estimated Annual Energy Cost 425.8 85.0 116.6 750.3 240.0 1617.6 This Home 62 0 20 40 60 80 100 120 140 Heating Cooling Water Heating Lights & App Photovoltaics Total MMBtu/yr Estimated Annual Energy Consumption 65.9 2.9 19.4 25.6 113.8 Name: Bancroft Address: 6026 Spindlebush Lane Fort Collins, CO 80528 House Type Single-family detached Cond. Area: 3440 sq. ft. Rating No.: 07112017093CRB Issue Date: July 14, 2017 Certification Verified Annual Estimates*: Electric(kWh): 8748 Natural gas(Therms): 840 C02 emissions(Tons): 13 Annual Savings**: $1264 * Based on standard operating conditions ** Based on a HERS 130 Index Home Burgess Construction Consultants 101 W. Renner Road, Suite 400 Certified Rater: Barrett Hendricks Rater ID: 6761425 Registry ID: 035991789 Rating Date: 07/14/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. © 1985-2017 Noresco, Boulder, Colorado.