Loading...
HomeMy WebLinkAbout6009 Sapling Ct - Disclosures/Final Energy - 08/30/2018Air Leakage Property Toll Brothers 6009 Sapling Court Fort Collins, CO 80528 Weather:Ft. Collins, CO Wakefield Partial Base 6009 Sapling Court.blg Organization Burgess Inc - BCCI 303-300-4527 Caleb Barczykowski Builder Toll Brothers Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. The 62.2-2013 rate incorporates any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Confirmed 08/30/2018 Rating No:03282018094CRB Rater ID:3244106 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.12 0.09 ACH @ 50 Pascals 2.61 2.61 CFM @ 25 Pascals 765 765 CFM @ 50 Pascals 1200 1200 Eff. Leakage Area (sq.in) 65.9 65.9 Specific Leakage Area 0.00018 0.00018 ELA/100 sf shell (sq.in) 0.94 0.94 CFM50/sf shell 0.17 0.17 Leakage to Outside Units Ducts CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0400 Mechanical Exhaust Only ASHRAE ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate (cfm) 58 48 58 Hours/Day 24.0 24.0 24.0 Fan Watts 11.3 Cooling Ventilation Natural Ventilation Component Loads Property Toll Brothers 6009 Sapling Court Fort Collins, CO 80528 Weather:Ft. Collins, CO Wakefield Partial Base 6009 Sapling Court.blg Organization Burgess Inc - BCCI 303-300-4527 Caleb Barczykowski Builder Toll Brothers REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Confirmed 08/30/2018 Rating No:03282018094CRB ID:3244106 Page 1 of 2 Heating Season MMBtu/yr Ceilings/Roofs 7.6 Rim/Band Joists 1.8 Above Grade Walls 24.0 Foundation Walls 4.6 Doors 1.8 Windows/Skylights 12.2 Floors 0.0 Crawl Space/Unht Bsmt 8.1 Slab Floors 2.3 Infiltration 3.6 Mechanical Ventilation 9.6 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -14.3 Total 61.4 Heating Season (MMBtu/yr) Ceilings/Roofs Rim/Band Joists Above Grade Walls Foundation Walls Doors Windows/Skylights Floors Crawl Space/Unht Bsmt Slab Floors Infiltration Mechanical Ventilation Ducts Active Solar Sunspace Internal Gains 0.00 5.00 10.00 Component Loads Property Toll Brothers 6009 Sapling Court Fort Collins, CO 80528 Weather:Ft. Collins, CO Wakefield Partial Base 6009 Sapling Court.blg Organization Burgess Inc - BCCI 303-300-4527 Caleb Barczykowski Builder Toll Brothers REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Confirmed 08/30/2018 Rating No:03282018094CRB ID:3244106 Page 2 of 2 Cooling Season MMBtu/yr Ceilings/Roofs 0.4 Rim/Band Joists -0.1 Above Grade Walls 0.1 Foundation Walls -0.4 Doors -0.1 Windows/Skylights 6.7 Floors 0.0 Crawl Space/Unht Bsmt -0.6 Slab Floors -1.0 Infiltration -0.1 Mechanical Ventilation -0.5 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains 9.3 Whole House Ventilation -3.6 Total 10.1 Cooling Season (MMBtu/yr) Ceilings/Roofs Rim/Band Joists Above Grade Walls Foundation Walls Doors Windows/Skylights Floors Crawl Space/Unht Bsmt Slab Floors Infiltration Mechanical Ventilation Ducts Active Solar Sunspace Internal Gains Whole House Ventilation 0.00 2015 IECC Energy Cost Compliance Property Toll Brothers 6009 Sapling Court Fort Collins, CO 80528 Weather:Ft. Collins, CO Wakefield Partial Base 6009 Sapling Court.blg Organization Burgess Inc - BCCI 303-300-4527 Caleb Barczykowski Builder Toll Brothers HERS Confirmed 08/30/2018 Rating No:03282018094CRB Rater ID:3244106 REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Annual Energy Cost $/yr 2015 IECC As Designed Heating 503 502 Cooling 155 130 Water Heating 104 104 SubTotal - Used to Determine Compliance 762 735 Mechanical Ventilation Fan 19 10 Lights & Appliances (minus MechVent) 625 578 Photovoltaics -0 -0 Service Charge 240 240 Total 1646 1564 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 3.5%. Name Caleb Barczykowski Signature Organization Burgess Inc - BCCI Date 30 August 2018 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 6009 Sapling Court, Fort Collins, CO by Toll Brothers exceeds the minimum requirements for the 2015 International Energy Conservation Code The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Building Features Ceiling Flat R-38.0 Duct NA Sealed Attic: NA Duct Leakage to Outside: 0.00 CFM25 / CFA Vaulted Ceiling NA Total Duct Leakage: 0.04 CFM25 / CFA Above Grade Walls R-21.0 Infiltration: Htg: 1200 Clg: 1200 CFM50 Foundation Walls R-19.0 Window U-Value: 0.310, SHGC: 0.290 Exposed Floor R-0.0 Heating Fuel-fired air distribution, Natural gas, 92.1 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.64 EF, 50.0 Gal. Name Caleb Barczykowski Signature Organization Burgess Inc - BCCI Date 30 August 2018 2015 IECC Certificate 6009 Sapling Court, Fort Collins, CO 80528 Building Envelope Insulation Ceiling R-38.0 Above Grade Walls R-21.0 Foundation Walls R-19.0 Exposed Floor R-0.0 Slab R-0.0 Edge, R-0.0 Under Infiltration Htg: 1200 Clg: 1200 CFM50 Duct NA Total Duct Leakage 0.04 CFM25 / CFA Window Data U-Factor SHGC Window 0.310 0.290 Mechanical Equipment HEAT: Fuel-fired air distribution, Natural gas, 92.1 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Natural gas, 0.64 EF, 50.0 Gal. Builder or Design Professional Signature REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 Home Energy Rating Certificate HERS Index: 64 REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. General Information Conditioned Area 2561 sq. ft. House Type Single-family detached Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Building Shell Features Ceiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 Under Lights and Appliance Features Percent Interior Lighting 100.00 Range/Oven Fuel Natural gas Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 62.6 $401 29% Criteria This home meets or exceeds the minimum criteria for the following: 2009 International Energy Conservation Code Conditioned Volume 27562 cubic ft. Foundation More than one type Cooling: Air conditioner, Electric, 13.0 SEER. Sealed Attic NA Exposed Floor R-0.0 Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric BurgessConstructionConsultantsInc Cooling 2.4 $69 5% 2012 International Energy Conservation Code Bedrooms 2 Water Heating: Conventional, Natural gas, 0.64 EF, 50.0 Gal. Vaulted Ceiling NA Window Type U-Value: 0.310, SHGC: 0.290 Refrigerator (kWh/yr) 475 Clothes Dryer CEF 2.32 1255 W 15th Street, Suite 900 Hot Water 16.0 $96 7% 2015 International Energy Conservation Code Duct Leakage to Outside 0.00 CFM25. Above Grade Walls R-21.0 Infiltration Rate Htg: 1200 Clg: 1200 CFM50 Dishwasher (kWh/yr) 260 Ceiling Fan (cfm/Watt) 0.00 Plano, TX 75075 Lights/Appliances 22.3 $588 42% Ventilation System Exhaust Only: 58 cfm, 11.3 watts. Foundation Walls R-19.0 Method Blower door 214-888-7260 Photovoltaics -0.0 $-0 -0% Programmable Thermostat Heat=Yes; Cool=Yes 214-888-7261 Service Charges $240 17% Total 103.3 $1395 100% Property HERS Toll Brothers Rating Type: Confirmed Certified Energy Rater: Caleb Barczykowski 6009 Sapling Court Rating Date: 08/30/2018 Rating Number: 03282018094CRB Fort Collins, CO 80528 Registry ID: 442991504 Certified Energy Rater: HERS PERFORMANCE REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. ENERGY RATING CERTIFICATE 64 Estimated Annual Energy Cost Heating Cooling Water Heating Lights & App Photovoltaics Service Charge Total 0 250 500 750 1000 1250 1500 $/yr 69 96 0 240 401 588 1,395 Estimated Annual Energy Consumption Heating Cooling Water Heating Lights & App Photovoltaics Total 0.0 20.0 40.0 60.0 80.0 100.0 120.0 MMBtu/yr 2.0 0.0 16.0 22.0 63.0 103.0 Address 6009 Sapling Court Fort Collins, CO 80528 House Type Single-family detached Cond. Area 2561 sq. ft. Rating No. 03282018094CRB Issue Date August 30, 2018 Certification Inspected and Tested Annual Estimates* Electric(kWh): 6747 Natural gas(Therms): 802 C02 emissions(Tons): 11 Annual Savings**: $1025 * Based on standard operating conditions ** Based on a HERS 130 Index Home BurgessConstructionConsultantsInc 1255 W 15th Street, Suite 900 Certified Rater Caleb Barczykowski Rater ID 3244106 Registry ID 442991504 Rating Date 08/30/2018 Signature 2.50 5.00 7.50 10.00 -2.50 -5.00 MMBtu/yr 0.40 -0.10 0.10 -0.40 -0.10 0.00 -0.60 -1.00 -0.10 -0.50 0.00 0.00 0.00 -3.60 6.70 9.30 15.00 20.00 25.00 -5.00 -10.00 -15.00 MMBtu/yr 0.00 0.00 0.00 0.00 -14.30 1.80 1.80 2.30 4.60 3.60 7.60 8.10 9.60 12.20 24.00