Loading...
HomeMy WebLinkAbout1624 Remington St - Special Inspections/Engineering - 12/12/2017FOUNDATION INSPECTION Job No. HONB1-15325-A2 Date signed: December 12, 2017 This is a verified password secured signature Bill Honn 1624 Remington Street Fort Collins, Colorado 80524 Re: Foundation inspection at the above residence Dear Mr. Honn: On December 12, 2017 I observed the soil at the bottom of the excavation for the foundation system designed by our firm for the above project. This soil consisted of a sandy clay, confirming our assumption that this soil is capable of supporting a maximum soil bearing pressure of 2,000 pounds per square foot per the 2015 International Residential Code Table R401.4.1. Accordingly, there is no need to change the thickened edge slab foundation system. I also observed the footing widths and reinforcing steel placed in the foundation forms at the subject site. All observed footing widths and foundation wall reinforcement met the specifications for size, type and installation as per the plans on file at the project site. Please feel free to contact our office if you have any questions. Very truly yours, COREY HRUTKAY, EI, BSCE MARK BENJAMIN, PE, MSCE, SECB, CPHC Certified in the practice of structural engineering Certified Passive House Consultant Copies: (1) verified password secured document. If submitting to a building department, provide CJDE with an email contact so that we may send it directly per most building department’s request.