HomeMy WebLinkAbout5932 Yellow Creek Dr - Disclosures/Blower Door Test - 08/22/2018BUILDING LEAKAGE TEST Date of Test: 8/22/2018 Test File: 5932 Yellow Creek dr bd Customer: RAH Technician: Michael Broussard Project Number: Building Address: 5932 Yellow Creek dr Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1552 CFM50 (+/-1.3 %) (50 Pa = 0.2 w.c.) 2.64 ACH50 2. Leakage Area: 85.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 113.3 (+/- 38.8 %) Exponent (n) = 0.669 ( +/- 0.099) Correlation Coefficient = 0.99883 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/22/2018 Test File: 5932 Yellow Creek dr bd Building Information Location Climate Information Volume 35232 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory I Model 3 (110V) I - a BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/22/2018 Test File: 5932 Yellow Creek dr bd Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 72.0 65.0 5500.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.3 n/a n/a -60.1 -59.9 91.2 1716 1759 0.5 Ring A -54.4 -54.2 78.2 1593 1632 -0.3 Ring A -49.6 -49.3 68.5 1493 1530 -0.6 Ring A -41.8 -41.6 55.2 1343 1377 0.4 Ring A -0.2 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters - Fewer than 8 data points were taken. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/22/2018 Test File: 5932 Yellow Creek dr bd Comments -48.4 pascals to garage=Passed