Loading...
HomeMy WebLinkAbout1352 Leahy Dr - Disclosures/Blower Door Test - 01/10/2018WGreen Your Home BUILDING LEAKAGE TEST Green Your Home^ Colleen Fitz -Gerald Henderson, CO 80640 Date of Test 1 /10/2018 Test File 1352 Leahy Dr - Magnolia - Techtite Customer Insignia Homes Technician Jason Robertson Fred Cooke Project Number 310 E 5th St Loveland, CO 80537 Building Address Magnolia Phone 970-379-7696 1352 Leahy Fort Collins, CO 80526 Test Results 1 Airflow at 50 Pascals (50Pa=02wc) 2 Leakage Area 3 Building Leakage Curve 4 Test Settings 5 Accuracy Level 1145 CFM50 (+/ 0 8 %) 1 59 ACH50 63 0 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 75 9 (+/ 6 8 % Exponent (n) = 0 694 ( +/- 0 017 ) Correlation Coefficient = 0 99952 Test Standard RESNET Multi -Point Test Test Mode Depressurization Standard Level of Accuracy Test Infiltration Estimates 1 Estimated Average Annual Infiltration Rate 2 Estimated Design Infiltration Rate Cost Estimates 1 Estimated Cost of Air Leakage for Heating 2 Estimated Cost of Air Leakage for Cooling a JA'Green Your Home BUILDING LEAKAGE TEST Page 2 of 4 Date of Test 1 /10/2018 Test File 1352 Leahy Dr - Magnolia - Techtite Building Information Location Climate Information Volume 43098 Surface Area Floor Area 4057 Height # of Bedrooms # of Occupants Year of Construction 2017 Wind Shield M 11 Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 9876 Micromanometer Energy Conservatory DG700 24427-7 JA'GreenYmrHome BUILDING LEAKAGE TEST Page 3 of 4 Date of Test 1 /10/2018 Test File 1352 Leahy Dr - Magnolia - Techtite Depressurization Test Environmental Data Indoor Temperature (°F) Outdoor Temperature (OF) Altitude (ft) 640 51 0 52800 Data Points - Data Entered Manually (TT 4.0.52.3) Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1 1 -20 0 -30 0 -40 0 -45 0 -50 0 -55 0 -60 0 -70 0 -80 0 -90 0 -1 1 Time Averaging Period: 10 n/a n/a -18 9 91 6 569 574 -1 6 Ring B -28 9 1758 786 792 1 2 Ring B -38 9 2688 970 978 1 7 Ring B -43 9 328 1043 1051 05 Ring A -48 9 381 1122 1131 03 Ring A -53 9 434 1195 1205 -0 1 Ring A -58 9 481 1257 1267 -1 2 Ring A -68 9 609 1410 1421 -0 6 Ring A -78 9 745 1555 1568 -0 2 Ring A -88 9 889 1695 1709 01 Ring A n/a n/a Deviations from Standard RESNET Multi -Point Test - Test Parameters None Green Your Home _ BUILDING LEAKAGE TEST Page 4 of 4 Date of Test 1 /10/2018 Test File 1352 Leahy Dr - Magnolia - Techtite Comments House to Garage -45 8 Pa Mechanical Ventilation Mechanical ventilation was measured at 235cfm at the Laundry Room Exhaust fan This measurement meets the Larimer County Mechanical Ventilation rate of 75 cfm continuous flow c