Loading...
HomeMy WebLinkAbout7413 Greenstone Trl - Disclosures/Final Energy - 01/09/20182012 IECC Energy Cost Compliance Property Spanjer Homes 7413 Greenstone Trail Fort Collins, CO 80525 0 Weather.Ft Collins, CO Rafiq Residence Spanjer - 7413 Greenstone Trail - Annual Energy Cost Organization GS Services Ltd (970) 449-1612 Paul Higman Builder Spanjer Homes Heating Cooling Water Heating SubTotal - Used to Determine Compliance Lights 13 Appliances Photovoltaics Service Charge Total Mandatory Requirements Annual Energy Cost Check Duct Insulation R-Value Check (per Section 405 2) Window U-Value and SHGC Check (per Section 402 5) Home Infiltration (Section 402.4.1 2) Duct Leakage (Section 403.2.2) Mechanical Ventilation (Section 403.5) Mechanical Ventilation Fan Efficacy (Section 403.5.1) Mandatory Requirements Check Box (2012 IECC) HERS Confirmed 2018-01-09 RaterlD•6784592 2012 IECC 1080 355 171 1606 1614 .0 240 3461 EM $/yr As Designed 1098 331 171 1600 1557 .0 240 3397 PASSES PASSES PASSES PASSES PASSES PASSES PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 0.4%. Digitally signed by Paul Signature H ig n Date 12 January 2018 Name Paul Higman Organization GS Services Ltd N = Paul inC=ADO Senaces LTD 201801 12 38.06'00' In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards REWRate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. ©1985-2017 Noresco, Boulder, Colorado. quguit HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 7413 Greenstone Trail, Fort Collins, CO by Spanjer Homes exceeds the minimum requirements for the 2012 International Energy Conservation Code Building Features Ceiling Flat R-49.0 Duct NA Sealed Attic: NA Duct Leakage to Outside. 0 00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage* 204.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration. Htg• 3325 Clg• 3 CFM50 Foundation Walls R-15.0 Window U-Value. 0.300, SHGC 0 310 Exposed Floor R-38.0 Heating Fuel -fired air distribution, Natural gas, 92.0 AFUE Slab R-0.0 Edge, R-0 0 Under Cooling Air conditioner, Electric, 13 0 SEER Water Heating Instant water heater, Natural gas, 0 88 EF, 0 0 Gal The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 56 and with all mandatory requirements. Digitally signed by: Name Paul Higman Signature Paul Higman Organization GSServices Ltd Date 12 January 2018 The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates REM/Rate - Residential Energy Analysis and Rating Software v15.4 1 a' �eI& '.�a'. a4& `ia`i40.�o�4.�a`i46. aa�ia� 4'�- 4 4&�i6%Z=11a City of Fort Collins Planning, Development &Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction SPA Guide 1. Submittal and Rating Type ❑ Stock Plan Permit— Projected Worst -Case Rating ❑ Lot -specific Permit - Projected Rating ❑ Completed Home — Confirmed Rating 2. Data Required for All SPA Ratings Builder Spanjer Homes Energy Rater Paul Higman Builder Model _ _ Address 7413 Greenstone Trail Address Rating Firm GS Services Date 1-09-18 Duct Location Inputs (REM/Rate "Duct Systems" page) Duct Location Su ply Return % Area R-Value % Area R-Value Main and basement with in conditioned space 100 r-0 100 r-0 Upper level system 100 r-8 100 r-8 Thermal Envelope Clarification Component Thermal Location Crawl space ® N/A ❑ Inside ❑ Outside Attic ❑ N/A ❑ Inside ® Outside Bonus room ® N/A ❑ Inside ❑ Outside Ductwork adjacent to garage M N/A ❑ Inside ❑ Outside Other ❑ N/A ❑Inside ❑Outside Utility Rates Energy Service I Variable Source Charge Rate Electricity 5 $/mo 01 $/kWh Natural 15 $/mo 0 6 $/therm as 3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating Worst -Case Configuration Front elevation Foundation orientation type(s) Options included ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑ Attach REM/Rate Energy Code Inspection Checklist 36. Additional Information for Lot -Specific Permit — Projected Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑ Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home — Confirmed Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS' (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date ) ❑ Attach REM/Rate Home Energy Rating Certificate Updated 03/01/2014