Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
412 W Laurel St - Special Inspections/Engineering - 01/08/2018
i FAI 7_ /7©733/ Gilbert Structural Engineering, LLC . 3113 Meadowlark Ave FortCollins, CO 80526 970.377.3100 January 8, 2018 Eric Swab- Superintendent Elder Construction 7380 Greendale Rd Windsor, CO 80550 Re: Wall Opening Kappa Delta Sorority 412 W Laurel St Fort Collins, CO GSE Project Number: 17-017 Eric: As requested, I met with you on December 21, 2017 at the referenced site to observe the installation of opening reinforcement for the new kitchen exhaust. The opening is 1'-6" x 1'-6" with the as -built location being off -center in the 5'-4" masonry pier of the western wall of the kitchen. Please see the attached photograph and the GSE report to Balance point dated July 3, 2017. An unknown existing condition was discovered during construction- the headedng of a floor joist above the new opening for a duct passing through the floor above. An additional as -built condition and deviation from the design plan was the installation of the specified L6x4x.31 lintel supporting the CMU block long leg vertical. The entire installation including the items identified above are structurally acceptable; it is my understanding the jambs of the new opening, the adjacent window, and the section of masonry above the new lintel are grouted. Sincerely, Glenn A Gilbert, PE Photo 1: View from kitchen interior looking west