Loading...
HomeMy WebLinkAbout1209 N College Ave - Special Inspections/Engineering - 10/05/2017HoffConstruction ®6966 Project: Lyric Cinema FC 1209 N. College Ave BP# B1606966 GC: Hoff Const. Special Inspections: Theatre Stadium Seating Framing 1815 West 12th Street I P.O. Box 7448 1 Loveland, CO 80537 1 Tel. 970.669.3255 1 Fax. 970.663.1566 www.hoffconstruction.com CTLITNOtwPSON Visual Weld and Bolt Report Date ,oiaao,7 Observation Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone 970-206-9455 Technician: Pappert, Jack Client Hoff Construction 1815 W 12th Street Loveland, CO 80537 Date: 09112/2017 Project FC06790 001-390 Proposed Lync Cinema 1209 N College Ave Ft Collins, CO Type of Inspection, Visual Weld (AWS D1 1 Table 6 1) / High Strength Bolt (AISC Spec for Structural Joints Using ASTM A325 or A490 Bolts, Sect 8,9) Weld Locations, At the Lyric Theater, we inspected the wood framing for the stadium seating area, including concrete slab attachments, joint splices, and header assemblies We observed that the header stud packs need additions to meet the plan requirements and that the structures in fire nser room interfere with the planned support joist Re -design of this area and re -inspection will be needed Plans By: CTL Thompson, dated 5-4-17 At the time of our observation, the items observed met the quality standards listed above: No Discrepancies were observed, see attached discrepancy list: Yes Oct 5 2017 1:13 PM Page 1 of 1 CTLITHOMPSON Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone 970-206-9455 Technician* Pappert, Jack Test Performed: weld/bolt Discrepancy: Yes Discrepancy List Client - Hoff Construction 1815 W 12th Street Loveland, CO 80537 Date: 09/12/2017 Protect FC06790 001-390 Proposed Lyric Cinema 1209 N College Ave Ft Collins, CO Report Date 10/4/2017 Discrepancy Information Item Number Item Description Status 500 For the wood framing for the stadium seating area, the header stud packs need additions to meet plan requirements, and the structures in fire nser room interfere with planned support joist Re -design of this area and re - inspection will be needed Notified Contractor: Yes Oct 5 2017 1:14 PM Page 1 of 1 CTLITHOMPSON Visual Weld and Bolt Report Date 10/4/2017 Observation Fort Collins 400 North Link Lane Fort Collins, CO80524 Phone 970-206-9455 Technician Pappert, Jack Client Hoff Construction 1815 W 12th Street Loveland, CO 80537 Data: 09121 /2017 Project FC06790 001-390 Proposed Lync Cinema 1209 N College Ave Ft Collins, CO Type of Inspection: Visual Weld (AWS D1 1 Table 6 1) / High Strength Bolt (AISC Spec for Structural Joints Using ASTM A325 or A490 Bolts, Sect 8,9) Weld Locations: At the Lyric Theater, we re -inspected the discrepancy items from the 9-12-17 inspection 1) Stud packs were fixed per original header schedule 2) Joist was adjusted per revised drawing in the fire riser room Plans By: CTL Thompson, no FC06790 000, updated 9-13-17 At the time of our observation, the Items observed met the quality standards listed above: Yes Discrepancies were observed, see attached discrepancy list: No Oct 5 2017 1:15 PM Page 1 of 1