Loading...
HomeMy WebLinkAbout1209 N College Ave - Special Inspections/Engineering - 05/18/2017Hoff Construction Project: Lyric Cinema FC 1209 N. College Ave BP# B1606966 GC: Hoff Const. Special Inspections: Welding / Bolting 1815 West 12th Street I P.O. Box 7448 1 Loveland, CO 80537 1 Tel. 970.669.3255 1 Fax. 970.663.1566 www.hoffconstruction.com CTLITHOIwPSON Visual Weld and Bolt Report Date:5/17/2017 Observation Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone 970-206-9455 Technician: Pappert, Jack Client: Hoff Construction 1815 W 12th Street Loveland, CO 80537 Date' 04/28/2017 Protect. FC06790 001-390 Proposed Lync Cinema 1209 N College Ave Ft Collins, CO Type of Inspection High Strength Bolt (AISC Spec. for Structural Joints Using ASTM A325 or A490 Bolts, Sect. 8,9) Bolt Locations: For the main framing at the new Lyric Cinema building, we inspected the 1/2-inch, 5/8-inch, 3/4-inch, and 1-inch diameter A325 bolts for the rafter beam to column, rafter beam splice, and strut beam to column connections at all gndlines All of the bolts were in the snug -tight condition or greater at the time of our inspection. Plans By Heath Steel, 14125, dated 1-12-17 At the time of our observation, the items observed met the quality standards listed above Yes Discrepancies were observed, see attached discrepancy list: No May 18 2017 4:46 PM Page 1 of 1 CTLITHOMPSON Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone 970-206-9455 Technician: Pappert, Jack Visual Weld and Bolt Observation Client* Hoff Construction 1815 W 12th Street Loveland, CO 80537 Date: 05/01 /2017 Protect. FC06790 001390 Proposed Lyric Cinema 1209 N College Ave Ft Collins, CO Type of Inspection Visual Weld (AWS D1.1 Table 6.1) / Anchor Bolts (Project Specifications) Report Date. 5/17/2017 Weld Locations - We inspected the 1/8-inch fillet welds of the angle brackets to the purlins and rafter beams at all gndlines of the new Lyric Cinema budding. 7018 electrodes, 1/8-mch fillet welds in the F, H and V positions. We inspected approximately 525 lineal inches of welds of which approximately 3% had been re -welded. We accepted 100% of the welds we inspected. Bolt Locations: We inspected the 1/2-inch and 3/4-inch diameter anchor bolts at all base plate connections All of the anchor bolts were in the snug - tight condition or greater at the time of our inspection. Plans By Chief Buildings, no. B3014125, dated 3-19-17 and Heath Steel, no. B3614125, dated 1-13-17. At the time of our observation, the items observed met the quality standards listed above- Yes Discrepancies were observed, see attached discrepancy list: No May 18 2017 4:47 PM Page 1 of 1 CTLITHOMPSON Visual Weld and Bolt Observation Report Date: 9/22/2017 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone_970-206-9455 Technician, Pappert, Jack Client: Hoff Construction 1815 W 12th Street Loveland, CO 80537 Date, 08/09/2017 Type of Inspection Visual Weld (AWS D1.1 Table 6.1) / Decking (AWS D1.3 Sect. 4.5) Project FC06790 001-390 Proposed Lync Cinema 1209 N College Ave Ft Collins, CO Weld Locations - For the stair landing framing at the mezzanine level, we inspected the 1/44nch fillet welds of the round steel columns to the column cap plates, of the column cap plates to the stair stringers, and of the 3 x 3 tube steel bracing to the stair stringers and beams. We also inspected the 5/16-inch puddle welds of the landing deck to the tube steel supports. 7018 electrodes, Miller Bobcat 250 machine, 1/4-inch fillet and 5/16-inch puddle welds in the H, V and O positions. We inspected approximately 160 lineal inches of welds of which approximately 5% had been re -welded. We accepted 100% of the welds we inspected. Note two site visits were required - the first on 8/8/17 and the second on 8/9/17. Plans By: CTL Thompson, no FC06790.000 addendum #3, dated 6-9-17 At the time of our observation, the items observed met the quality standards listed above: Yes Discrepancies were observed, see attached discrepancy list: No Sep 22 2017 2:38 PM Page 1 of 1 . �CTLITHOMPSON Visual Weld and Bolt ReportDate: 9/22/2017 � Observation • Fort Collins Client: Pro�ect 400 North Link Lane Fort Collins,CO 80524 Hof(Construchon FC06790 001�90 Phone 970-20fr9455 1815 W 12th Street � Proposed Lync Gnema Loveland,CO 80537 1209 N College Ave FtCoOins,CO Techniaan: pappert, Jack Date. 08/16I2017 Type of Inspection Visual Weld(AWS D1.1 Table 6.1) Weld Locations• The west landing column had been moved 6 inches north to accommodate electric-this move had been approved by the Engineer of Record(Scott Hargrove with CTL Thompson). For the moved column,we inspected the re-weldmg of the column cap plate to the stnnger by 1/4-inch fillet welds.We also inspected the titan screws at the column base plate.Miller Bobcat 250 machine, 7018 electrodes, 1/4inch fillet welds in the O position.We mspected approximately 20 lineal mches of welds.We accepted 100%of the welds we inspected. Plans By. CTL Thompson, no.FC06790.000 addendum#3,dated 6-9-17 At the time of our observation,the items observed met the quality standards listed above Yes Discrepancies were observed,see attached discrepancy list: No ,� �4,�Q/Sr� ��. , 3E1�� : . .. . . . : . � � �•.. ..• toriA�. Sep 22 2017 2:39 PM Page 1 of 1