HomeMy WebLinkAbout1209 N College Ave - Special Inspections/Engineering - 05/18/2017Hoff Construction
Project: Lyric Cinema FC
1209 N. College Ave
BP# B1606966
GC: Hoff Const.
Special Inspections:
Welding / Bolting
1815 West 12th Street I P.O. Box 7448 1 Loveland, CO 80537 1 Tel. 970.669.3255 1 Fax. 970.663.1566
www.hoffconstruction.com
CTLITHOIwPSON Visual Weld and Bolt Report Date:5/17/2017
Observation
Fort Collins
400 North Link Lane
Fort Collins, CO 80524
Phone 970-206-9455
Technician: Pappert, Jack
Client:
Hoff Construction
1815 W 12th Street
Loveland, CO 80537
Date' 04/28/2017
Protect.
FC06790 001-390
Proposed Lync Cinema
1209 N College Ave
Ft Collins, CO
Type of Inspection High Strength Bolt (AISC Spec. for Structural Joints Using ASTM A325 or A490 Bolts, Sect. 8,9)
Bolt Locations:
For the main framing at the new Lyric Cinema building, we inspected the 1/2-inch, 5/8-inch, 3/4-inch, and 1-inch diameter A325 bolts
for the rafter beam to column, rafter beam splice, and strut beam to column connections at all gndlines All of the bolts were in the
snug -tight condition or greater at the time of our inspection.
Plans By Heath Steel, 14125, dated 1-12-17
At the time of our observation, the items observed met the quality standards listed above Yes
Discrepancies were observed, see attached discrepancy list: No
May 18 2017 4:46 PM
Page 1 of 1
CTLITHOMPSON
Fort Collins
400 North Link Lane
Fort Collins, CO 80524
Phone 970-206-9455
Technician: Pappert, Jack
Visual Weld and Bolt
Observation
Client*
Hoff Construction
1815 W 12th Street
Loveland, CO 80537
Date: 05/01 /2017
Protect.
FC06790 001390
Proposed Lyric Cinema
1209 N College Ave
Ft Collins, CO
Type of Inspection Visual Weld (AWS D1.1 Table 6.1) / Anchor Bolts (Project Specifications)
Report Date. 5/17/2017
Weld Locations -
We inspected the 1/8-inch fillet welds of the angle brackets to the purlins and rafter beams at all gndlines of the new Lyric Cinema
budding. 7018 electrodes, 1/8-mch fillet welds in the F, H and V positions. We inspected approximately 525 lineal inches of welds of
which approximately 3% had been re -welded. We accepted 100% of the welds we inspected.
Bolt Locations:
We inspected the 1/2-inch and 3/4-inch diameter anchor bolts at all base plate connections All of the anchor bolts were in the snug -
tight condition or greater at the time of our inspection.
Plans By Chief Buildings, no. B3014125, dated 3-19-17 and Heath Steel, no. B3614125, dated 1-13-17.
At the time of our observation, the items observed met the quality standards listed above- Yes
Discrepancies were observed, see attached discrepancy list: No
May 18 2017 4:47 PM
Page 1 of 1
CTLITHOMPSON
Visual Weld and Bolt
Observation
Report Date: 9/22/2017
Fort Collins
400 North Link Lane
Fort Collins, CO 80524
Phone_970-206-9455
Technician, Pappert, Jack
Client:
Hoff Construction
1815 W 12th Street
Loveland, CO 80537
Date, 08/09/2017
Type of Inspection Visual Weld (AWS D1.1 Table 6.1) / Decking (AWS D1.3 Sect. 4.5)
Project
FC06790 001-390
Proposed Lync Cinema
1209 N College Ave
Ft Collins, CO
Weld Locations -
For the stair landing framing at the mezzanine level, we inspected the 1/44nch fillet welds of the round steel columns to the
column cap plates, of the column cap plates to the stair stringers, and of the 3 x 3 tube steel bracing to the stair stringers and beams.
We also inspected the 5/16-inch puddle welds of the landing deck to the tube steel supports. 7018 electrodes, Miller Bobcat 250
machine, 1/4-inch fillet and 5/16-inch puddle welds in the H, V and O positions. We inspected approximately 160 lineal inches of
welds of which approximately 5% had been re -welded. We accepted 100% of the welds we inspected. Note two site visits were
required - the first on 8/8/17 and the second on 8/9/17.
Plans By: CTL Thompson, no FC06790.000 addendum #3, dated 6-9-17
At the time of our observation, the items observed met the quality standards listed above: Yes
Discrepancies were observed, see attached discrepancy list: No
Sep 22 2017 2:38 PM
Page 1 of 1
. �CTLITHOMPSON Visual Weld and Bolt ReportDate: 9/22/2017
� Observation
• Fort Collins Client: Pro�ect
400 North Link Lane
Fort Collins,CO 80524 Hof(Construchon FC06790 001�90
Phone 970-20fr9455 1815 W 12th Street � Proposed Lync Gnema
Loveland,CO 80537 1209 N College Ave
FtCoOins,CO
Techniaan: pappert, Jack Date. 08/16I2017
Type of Inspection Visual Weld(AWS D1.1 Table 6.1)
Weld Locations•
The west landing column had been moved 6 inches north to accommodate electric-this move had been approved by the Engineer of
Record(Scott Hargrove with CTL Thompson). For the moved column,we inspected the re-weldmg of the column cap plate to the
stnnger by 1/4-inch fillet welds.We also inspected the titan screws at the column base plate.Miller Bobcat 250 machine, 7018
electrodes, 1/4inch fillet welds in the O position.We mspected approximately 20 lineal mches of welds.We accepted 100%of the
welds we inspected.
Plans By. CTL Thompson, no.FC06790.000 addendum#3,dated 6-9-17
At the time of our observation,the items observed met the quality standards listed above Yes
Discrepancies were observed,see attached discrepancy list: No
,� �4,�Q/Sr�
��.
, 3E1�� :
.
.. .
. .
:
. � �
�•.. ..•
toriA�.
Sep 22 2017 2:39 PM
Page 1 of 1