Loading...
HomeMy WebLinkAbout1017 Sabatino Ln - Disclosures/Final Energy - 11/14/2017City of Fort Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction SPA Guide 1. Submittal and Rating Type El Stock Plan Permit— Projected Worst -Case Rating ❑ Lot -specific Permit - Projected Rating Completed Home — Confirmed Rating 2. Data Required for All SPA Ratings Builder: Armstead Construction Energy Rater: Nick Hlseler Builder Model: Interior Ranch Unit Address: 1017 §abatino Lane Address: Rating Firm: GS Services Date: 11 /14/17 Duct Location Inputs REM/Rate "Duct Systems" page Duct Location Supply Return % Area R-Value % Area I R-Value Conditioned Area 100 0 100 0 Thermal Envelope Clarification Component Thermal Location Crawl space ❑Q N/A ❑ Inside ❑Outside Attic [:]N/A [:]Inside ❑� Outside Bonus room II N/A ❑ Inside ❑Outside Ductwork adjacent to garage 0 N/A []Inside ❑Outside Other: ❑ N/A ❑ Inside ❑Outside Utility Rates Energy Service Variable Source Charge Rate Electricity $/mo $/kWh Natural $/mo $/therm as 3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating Worst -Case Configuration Front elevation Foundation orientation East e s Garden Options included ❑Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑Attach REM/Rate Energy Code Inspection Checklist 3B. Additional Information for Lot -Specific Permit — Projected Rating ❑Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home — Confirmed Rating ElAttach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) BAttach REM/Rate Home Energy Rating Certificate 15140k) 17 3:01PM Updated 03/01/2014 Air Leakage Property Armstead Construction 1017 Sabatino Ln Fort Collins, CO Weather:Ft. Collins, CO Interior Unit Armstead Construction - 1017 Sabatino Lane - Interior Ranch Whole House Infiltration Duct Leakage Ventilation Organization GS Services Ltd (970)449-1612 Builder Armstead Construction Natural ACH ACH 50 Pascals CFM 25 Pascals CFM @ 50 Pascals Eff. Leakage Area (sq.in) Specific Leakage Area ELA/100 sf shell (sq.in) Leakage to Outside Units CFM @ 25 Pascals CFM25 / CFMfan CFM25 / CFA CFM per Std 152 CFM per Std 152 / CFA CFM @ 50 Pascals Eff. Leakage Area (sq.in) Thermal Efficiency Total Duct Leakage Units Total Duct Leakage Mechanical Sensible Recovery Eff. (%) Total Recovery Eff. (%) Rate (cfm) Hours/Day Fan Watts Cooling Ventilation HERS dRseervices. Rater ID: Blower Door Test Heating Cooling 0.15 0.11 2.44 2.44 785 785 1232 1232 67.6 67.6 0.00016 0.00016 1.07 1.07 Fnlirc Wniinc 0 0.0000 0.0000 N/A N/A 0 0.00 N/A CFM25/CFA 0.0399 Exhaust Only ASHRAE ASHRAE 0.0 62.2-2010 62.2-2013 0.0 52 51 108 24.0 24.0 24.0 24.0 Natural Ventilation ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the Whole -building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.2 This information does not constitute any warranty of energy cost or savings. ® 1985-2016 Noresco, Boulder, Colorado. 201 2 IECC En�ray Cost Con��•�li��nc�� Property Armstead Construction 1017 Sabatino Ln Fort Collins, CO Weather:Ft. Collins, CO Interior Unit Armstead Construction - 1017 Annual Energy Cost Organization GS Services Ltd (970)449-1612 Builder Armstead Construction (Heating — ------------ Cooling l Water Heating ISubTotal - Used to Determine Compliance Lights 13 Appliances Photovoltaics Service Charge Total Mandatory Requirements __ _ ;Annual Energy Cost Check Duct insulation R-Value Check (per Section 405.2) i Window U-Value and SHGC Check (per Section 402.5) 1 Home Infiltration (Section 402.4.1.2) Duct Leakage (Section 403.2.2) Mechanical Ventilation (Section 403.6) Mechanical Ventilation Fan Efficacy (Section 403.5.1) Mandatory Requirements Check Box (2012 IECC) HERS Rater ID: $/yr 2012 IECC As Designed — - 323 — - - -- - _--332 136 100 96 96 555 528 694 695 -0 -0 240 240 1489 1464 PASSES PASSES PASSES PASSES PASSES PASSES PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 4.8%. Nick DigWy sgnB by: Nitl Hmeler DN: CN a Nitl Hiseler email = Hiseler a oMse m�gue Wces.emal C=us0 Name Signature ��=csseMee4 g `Date: 2017.11.1415:55:21-0TVY Organization GS Services Ltd Date 14 November 2017 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v15.2 This information does not constitute any warranty of energy cost or savings. 0 1985-2016 Noresco, Boulder, Colorado. O /_�OI�OI�OI� Oil O/_� o i�0/1 Oil O/_�O1�0/�9 r\OI�Or\Or�Or\9r\O/\O/\9l\O/19l\4 HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 1017 Sabatino Ln, Fort Collins, CO by Armstead Construction exceeds the minimum requirements for the 2012 International Energy Conservation Code Building Features _ F Ceiling Flat R-49.0 Duct NA i Sealed Attic: NA Duct Leakage to Outside: 0.00 CFM ® 25 Pascals !, Vaulted Ceiling NA Total Duct Leakage: 114.00 CFM @ 25 Pascals Above Grade Walls R-23.0 Infiltration: Htg: 1232 Ctg: 1232 CFM50 Foundation Walls R-19.0 Window U-Value: 0.300, SHGC: 0.190 � Exposed Floor NA Heating Fuel -fired air distribution, Natural gas, 92.1 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Instant water heater, Natural gas, 0.88 EF, 0.0 Gal_ The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Name Signature JJ Organization GS Services Ltd Date November 14, 2017 The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software 05.2 2012 IECC Certificate 1017 Sabatino Ln, Fort Collins, CO -- — --- -- — -- � �Bu9lding Envelope Insulation _ J Ceiling R-49.0 Above Grade Walls R-23.0 Foundation Walls R-19.0 Exposed Floor NA Slab R-0.0 Edge, R-0.0 Under Infiltretion Htg: 1232 Clg: 1232 CFM50 Duct NA Total Duct Leakage 114.00 CFM @ 25 Pascals {Window Data U-Factor SHGC`� Window 0.300 0.190 iMechanicalEquipment __� i� HEAT: Fuel-fired air distribution, Natural gas, 92.1 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Instant water heater, Natural gas, 0.88 EF, 0.0 Gal. �Builder or Design Professional � --------- --- --- Signature REM/Rate-Residential Energy Malysis and Rating Software v15.2