HomeMy WebLinkAbout1017 Sabatino Ln - Disclosures/Final Energy - 11/14/2017City of
Fort Collins Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction
SPA Guide
1. Submittal and Rating Type
El Stock Plan Permit— Projected Worst -Case Rating
❑ Lot -specific Permit - Projected Rating
Completed Home — Confirmed Rating
2. Data Required for All SPA Ratings
Builder: Armstead Construction
Energy Rater: Nick Hlseler
Builder Model: Interior Ranch Unit
Address: 1017 §abatino Lane
Address:
Rating Firm: GS Services
Date: 11 /14/17
Duct Location Inputs REM/Rate "Duct Systems" page
Duct Location
Supply
Return
% Area
R-Value
% Area
I R-Value
Conditioned Area
100
0
100
0
Thermal Envelope
Clarification
Component
Thermal Location
Crawl space
❑Q N/A
❑ Inside
❑Outside
Attic
[:]N/A
[:]Inside
❑� Outside
Bonus room
II N/A
❑ Inside
❑Outside
Ductwork adjacent to garage
0 N/A
[]Inside
❑Outside
Other:
❑ N/A
❑ Inside
❑Outside
Utility Rates
Energy
Service
Variable
Source
Charge
Rate
Electricity
$/mo
$/kWh
Natural
$/mo
$/therm
as
3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating
Worst -Case Configuration
Front elevation Foundation
orientation East e s Garden
Options
included
❑Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
❑Attach REM/Rate Energy Code Inspection Checklist
3B. Additional Information for Lot -Specific Permit — Projected Rating
❑Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
❑Attach REM/Rate Energy Code Inspection Checklist
3C. Additional Information for Completed Home — Confirmed Rating
ElAttach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
BAttach REM/Rate Home Energy Rating Certificate
15140k) 17 3:01PM
Updated 03/01/2014
Air Leakage
Property
Armstead Construction
1017 Sabatino Ln
Fort Collins, CO
Weather:Ft. Collins, CO
Interior Unit
Armstead Construction - 1017
Sabatino Lane - Interior Ranch
Whole House Infiltration
Duct Leakage
Ventilation
Organization
GS Services Ltd
(970)449-1612
Builder
Armstead Construction
Natural ACH
ACH 50 Pascals
CFM 25 Pascals
CFM @ 50 Pascals
Eff. Leakage Area (sq.in)
Specific Leakage Area
ELA/100 sf shell (sq.in)
Leakage to Outside Units
CFM @ 25 Pascals
CFM25 / CFMfan
CFM25 / CFA
CFM per Std 152
CFM per Std 152 / CFA
CFM @ 50 Pascals
Eff. Leakage Area (sq.in)
Thermal Efficiency
Total Duct Leakage Units
Total Duct Leakage
Mechanical
Sensible Recovery Eff. (%)
Total Recovery Eff. (%)
Rate (cfm)
Hours/Day
Fan Watts
Cooling Ventilation
HERS dRseervices.
Rater ID:
Blower Door
Test
Heating
Cooling
0.15
0.11
2.44
2.44
785
785
1232
1232
67.6
67.6
0.00016
0.00016
1.07
1.07
Fnlirc Wniinc
0
0.0000
0.0000
N/A
N/A
0
0.00
N/A
CFM25/CFA
0.0399
Exhaust Only
ASHRAE
ASHRAE
0.0
62.2-2010
62.2-2013
0.0
52
51
108
24.0
24.0
24.0
24.0
Natural Ventilation
ASHRAE 62.2 - Ventilation Requirements
The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the Whole -building'
requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent
mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours
per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to
the appropriate standard.
REM/Rate - Residential Energy Analysis and Rating Software v15.2
This information does not constitute any warranty of energy cost or savings.
® 1985-2016 Noresco, Boulder, Colorado.
201 2 IECC En�ray Cost Con��•�li��nc��
Property
Armstead Construction
1017 Sabatino Ln
Fort Collins, CO
Weather:Ft. Collins, CO
Interior Unit
Armstead Construction - 1017
Annual Energy Cost
Organization
GS Services Ltd
(970)449-1612
Builder
Armstead Construction
(Heating — ------------
Cooling
l Water Heating
ISubTotal - Used to Determine Compliance
Lights 13 Appliances
Photovoltaics
Service Charge
Total
Mandatory Requirements
__ _
;Annual Energy Cost Check
Duct insulation R-Value Check (per Section 405.2)
i Window U-Value and SHGC Check (per Section 402.5)
1 Home Infiltration (Section 402.4.1.2)
Duct Leakage (Section 403.2.2)
Mechanical Ventilation (Section 403.6)
Mechanical Ventilation Fan Efficacy (Section 403.5.1)
Mandatory Requirements Check Box (2012 IECC)
HERS
Rater ID:
$/yr
2012 IECC
As Designed
— - 323 —
- - -- - _--332
136
100
96
96
555
528
694
695
-0
-0
240
240
1489
1464
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code
based on a climate zone of 5B. In fact, this home surpasses the requirements by 4.8%.
Nick DigWy sgnB by: Nitl Hmeler
DN: CN a Nitl Hiseler email =
Hiseler a oMse m�gue Wces.emal C=us0
Name Signature ��=csseMee4
g `Date: 2017.11.1415:55:21-0TVY
Organization GS Services Ltd Date 14 November 2017
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate - Residential Energy Analysis and Rating Software v15.2
This information does not constitute any warranty of energy cost or savings.
0 1985-2016 Noresco, Boulder, Colorado.
O /_�OI�OI�OI� Oil O/_� o i�0/1 Oil O/_�O1�0/�9 r\OI�Or\Or�Or\9r\O/\O/\9l\O/19l\4
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
1017 Sabatino Ln, Fort Collins, CO
by Armstead Construction
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features _
F Ceiling Flat R-49.0 Duct NA i
Sealed Attic: NA Duct Leakage to Outside: 0.00 CFM ® 25 Pascals
!, Vaulted Ceiling NA Total Duct Leakage: 114.00 CFM @ 25 Pascals
Above Grade Walls R-23.0 Infiltration: Htg: 1232 Ctg: 1232 CFM50
Foundation Walls R-19.0 Window U-Value: 0.300, SHGC: 0.190
� Exposed Floor NA Heating Fuel -fired air distribution, Natural gas, 92.1 AFUE.
Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER.
Water Heating Instant water heater, Natural gas, 0.88 EF, 0.0 Gal_
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5B and with all mandatory requirements.
Name Signature JJ
Organization GS Services Ltd Date November 14, 2017
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software 05.2
2012 IECC Certificate
1017 Sabatino Ln, Fort Collins, CO
-- — --- -- — -- �
�Bu9lding Envelope Insulation _ J
Ceiling R-49.0
Above Grade Walls R-23.0
Foundation Walls R-19.0
Exposed Floor NA
Slab R-0.0 Edge, R-0.0 Under
Infiltretion Htg: 1232 Clg: 1232 CFM50
Duct NA
Total Duct Leakage 114.00 CFM @ 25 Pascals
{Window Data U-Factor SHGC`�
Window 0.300 0.190
iMechanicalEquipment __� i�
HEAT: Fuel-fired air distribution, Natural gas, 92.1 AFUE.
COOL: Air conditioner, Electric, 13.0 SEER.
DHW: Instant water heater, Natural gas, 0.88 EF, 0.0 Gal.
�Builder or Design Professional �
--------- --- ---
Signature
REM/Rate-Residential Energy Malysis and Rating Software v15.2