HomeMy WebLinkAbout1926 Blue Yonder Way - Disclosures/Blower Door Test - 04/07/2017¢DnergyLogic analysis insight answers. www.rLrglogic.com BUILDING LEAKAGE TEST Date of Test 4/7/2016 Test File Multi Point Tectite 1926 Customer DR Horton Technician Trevor Donnelly- EnergyLogic Project Number 45637 Building Address 1926 Blue Yonder Way Fort Collins, CO 80525 Test Results 1 Airflow at 50 Pascals 1391 CFM50 (+/- 3 3 %) (50Pa=02wc) 216ACH50 2 Leakage Area 76 5 in2 LBL ELA @ 4 Pa 3 Building Leakage Curve Flow Coefficient (C) = 51 9 (+/- 55 7 %) Exponent (n) = 0 841 ( +/- 0 146 ) Correlation Coefficient = 0 98515 4 Test Settings Test Standard RESNET Multi -Point Test Test Mode Depressurization 5 Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1 Estimated Average Annual Infiltration Rate 81 1 CFM 0 13ACH 20 3 CFM per person 2 Estimated Design Infiltration Rate Winter 152 6 CFM Summer 95 8 CFM 0 24 ACH 0 15 ACH Cost Estimates 1 Estimated Cost of Air Leakage for Heating 2 Estimated Cost of Air Leakage for Cooling Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate 68 4 CFM Base Rate 69 5 CFM Infiltration Credit <1 1 CFM> 0 No Text No Text No Text