HomeMy WebLinkAbout1926 Blue Yonder Way - Disclosures/Blower Door Test - 04/07/2017¢DnergyLogic
analysis insight answers.
www.rLrglogic.com
BUILDING LEAKAGE TEST
Date of Test 4/7/2016 Test File Multi Point Tectite 1926
Customer DR Horton Technician Trevor Donnelly- EnergyLogic
Project Number 45637
Building Address 1926 Blue Yonder Way
Fort Collins, CO 80525
Test Results
1 Airflow at 50 Pascals 1391 CFM50 (+/- 3 3 %)
(50Pa=02wc) 216ACH50
2 Leakage Area 76 5 in2 LBL ELA @ 4 Pa
3 Building Leakage Curve Flow Coefficient (C) = 51 9 (+/- 55 7 %)
Exponent (n) = 0 841 ( +/- 0 146 )
Correlation Coefficient = 0 98515
4 Test Settings Test Standard RESNET Multi -Point Test
Test Mode Depressurization
5 Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1 Estimated Average Annual Infiltration Rate 81 1 CFM
0 13ACH
20 3 CFM per person
2 Estimated Design Infiltration Rate Winter 152 6 CFM Summer 95 8 CFM
0 24 ACH 0 15 ACH
Cost Estimates
1 Estimated Cost of Air Leakage for Heating
2 Estimated Cost of Air Leakage for Cooling
Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010)
Recommended Whole Bldg Rate 68 4 CFM
Base Rate 69 5 CFM
Infiltration Credit <1 1 CFM>
0