HomeMy WebLinkAbout6602 Avondale Rd - Disclosures/Blower Door Test - 08/24/2017QnergyLogic
an a I Ysis. Ins I ghl. an$.*,,.
BUILDING LEAKAGE>TEST� J cJ
Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE
Customer: Habitat for Humanity (Ft. Collins) Technician: Zach Kimbrough - EnergyLogic
Project Number: 45988
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
Building Address: 6602 Avondale Rd -Unit E
Ft Collins, CO 80525
310CFM50(+/-1.5%)
1.06 ACH50
17.0 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 12.4 (+/- 10.8 %)
Exponent (n) = 0.822 ( +/- 0.030 )
Correlation Coefficient = 0.99934
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
18.1 CFM
0.06 ACH
4.5 CFM per person
Winter: 33.9 CFM Summer: 21.3 CFM
0.12ACH 0.07ACH
QnergyLogic
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE
Building Information Location Climate Information
Volume
17560.4
Surface Area
Floor Area
1960
Height
20
# of Bedrooms
3
# of Occupants
4
Year of Construction
2017
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
26986-7
8/2/2010
QnergyLogic
%i
BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE
Depressurization Test:
Environmental Data
Indoor Temperature (°F)
Outdoor Temperature (°F)
Altitude (ft)
75.0
90.0
5200.0
Data Points
Nominal
Baseline Adjusted
Fan
Building Pressure
Building Pressure
Pressure
(Pa)
(Pa)
(Pa)
-2.4
n/a
n/a
-61.6
-58.9
29.2
-56.3
-53.6
25.1
-51.4
-48.7
137.3
-44.2
-41.5
108.3
-38.5
-35.8
84.7
-32.5
-29.9
64.7
-26.5
-23.8
44.9
-20.5
-17.8
29.0
-3.0
n/a
n/a
Time Averaging Period: 0
None
Nominal Adjusted
Flow Flow Fan
(cfm) (cfm) % Error Configuration
322
359
1.4
Ring B
299
333
1.6
Ring B
267
298
-1.8
Ring C
237
263
-0.7
Ring C
209
232
-1.2
Ring C
182
202
-0.2
Ring C
151
168
-0.3
Ring C
120
134
1.2
Ring C
Deviations from Standard RESNET Multi -Point Test - Test Parameters
QnergyLogic
BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE
Comments
Garage:-50 PA
Mech: -50 PA