HomeMy WebLinkAbout6602 Avondale Rd - Disclosures/Blower Door Test - 08/24/2017QnergyLogic an a I Ysis. Ins I ghl. an$.*,,. BUILDING LEAKAGE>TEST� J cJ Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE Customer: Habitat for Humanity (Ft. Collins) Technician: Zach Kimbrough - EnergyLogic Project Number: 45988 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Building Address: 6602 Avondale Rd -Unit E Ft Collins, CO 80525 310CFM50(+/-1.5%) 1.06 ACH50 17.0 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 12.4 (+/- 10.8 %) Exponent (n) = 0.822 ( +/- 0.030 ) Correlation Coefficient = 0.99934 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 18.1 CFM 0.06 ACH 4.5 CFM per person Winter: 33.9 CFM Summer: 21.3 CFM 0.12ACH 0.07ACH QnergyLogic BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE Building Information Location Climate Information Volume 17560.4 Surface Area Floor Area 1960 Height 20 # of Bedrooms 3 # of Occupants 4 Year of Construction 2017 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 26986-7 8/2/2010 QnergyLogic %i BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 75.0 90.0 5200.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -2.4 n/a n/a -61.6 -58.9 29.2 -56.3 -53.6 25.1 -51.4 -48.7 137.3 -44.2 -41.5 108.3 -38.5 -35.8 84.7 -32.5 -29.9 64.7 -26.5 -23.8 44.9 -20.5 -17.8 29.0 -3.0 n/a n/a Time Averaging Period: 0 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 322 359 1.4 Ring B 299 333 1.6 Ring B 267 298 -1.8 Ring C 237 263 -0.7 Ring C 209 232 -1.2 Ring C 182 202 -0.2 Ring C 151 168 -0.3 Ring C 120 134 1.2 Ring C Deviations from Standard RESNET Multi -Point Test - Test Parameters QnergyLogic BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/24/2017 Test File: 6602 Avondale RdUnit E HFH FC TECTITE Comments Garage:-50 PA Mech: -50 PA