Loading...
HomeMy WebLinkAbout4725 Venturi Ln - Disclosures/Blower Door Test - 11/17/2017BUILDING LEAKAGE TEST G8t-4S"er • � S Services, LTD. V, 2000S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 11/17/2017 Customer: Lauren Ashley Homes aIV10LIS1O Test File: Lauren Ashley Homes E 4725 Verrt � BD1 Technician: Nick Hiseler Project Number. Building Address: 4725 Venturi Lane Fort Collins, CO Test Results 1. Airflow at 50'Pascals. 2248 CFM50 ( +1- 1.6 %) (50 Pa = 0.2 w c.) 2.67 ACH50 2. Leakage Area: 123.7 in2 LBL ELA @ 4 Pa 3. Budding Leakage Curve: Flow Coefficient (C) = 155 7 (+/- 116 %) Exponent (n) = 0 682 (.+/- 0 032 ) Correlation Coefficient = 0 99889 4 Test Settings Test Standard: RESNET Multi -Point Test Test Mode. Depressurization 5 Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual %Infiltration Rate: 2 Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2 Estimated Cost of Air Leakage for Cooling: Nick DI* - b, ' m Hiseler n ERA GSA--,-,ms BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/17/2017 Test File: Lauren Ashley Homes - 4725 Ventun Lane - BD1 Building Information Volume 50498 Surface Area Floor Area 4585 Height # of Bedrooms '# of Occupants Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas HeatingFuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00, Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph 'Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Drff 15 deg F Equipment Information Type Manufacturer Model Serial Number 'Custom -Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory OG700 19028 9/9/2014 GS Sep -- .BlAL`DING�LEAKAGE VEST Page 3 of 4 Date of Test: 11/17/2017 Test File: Lauren Ashley Homes - 4725 Venturi Lane - BD1 Depressurization Test. Environmental Data Indoor Temperature (°F) Outdoor Temperature (OF) Attitude (ft) 650 1 630 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure 'Building,Pressure Pressure ,Flow Flow Fan (Pa) (Pa) (Pa) (efm) (cim) % Error Configuration 1.4 n/a o/a -55.3 -56.9 1845 2420 2485 1.2 Ring A -51.3 -52.9 162.0 2271 2333 -0.2 Ring A -47.0 -48.6 143.6 2142 2200 -02 Rang A -40.3 -41.9 118.6 1951 2003 0.5 Rang A -34.4 -36.0 933 1735 1782 -0.7 Ring A -28 1 -29.6 704 1513 1554 -1.2 Ring A -21.4 -22 9 487 1264 1298 -1.7 Ring A -16.8 -18.3 38.6 1129 1159 23 Ring A 17 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET, Multi -Point Test - Test Parameters 'None S $emGelS --- BUILDING LEAKAGE TEST Page 4 of 4 .Date of Test- 11/17/2017 Test,Fde: Lauren Ashley Homes - 4725 Ventun Lane - BD1 Comments House WRT Garage = -47.1 Pa