Loading...
HomeMy WebLinkAbout2602 Palomino Ct - Disclosures/Final Energy - 07/31/2017Home Energy Rating Certificate Rating Date: 7/31/17 (DnergyLogic Registry ID: 273898405 ^^ Final Report Rating Number: 273898405 Your Home's Estimated Energy Use: Use [MBtuj Annual Cost Heating 71.9 $537 Cooling 1.8 $53 Hot Water 18.7 $112 Lights/Appliances 32.5 $953 Service Charges $240 Generation (e.g. Solar) 0.0 -$0 Total: 124.9 $1,894 Home Feature Summary: r,a- rmM Eft'm Home Type: Single family detached ao Conditioned Floor Area: 5,091 sq. ft. Homeg sao Number of Bedrooms: 3 rw m Primary Heating System: Furnace • Natural Gas • 92.1 AFUE 110 Reference WIF 100 Primary Cooling System: Air Conditioner • Electric • 13 SEER Home Primary Water Heating: Water Heater. Natural Gas • 059 Energy Factor soso House Tightness: 1530 CFM50 (1.8 ACH50) �o Duct Leakage to Outside: 0 CFM25 60 Above Grade Walls: R-21 so ao This Home Ceiling: R-38 w Window Type: U-Value: 0.310, SHGC: 0360 ae Foundation Walls: R-19 Zero Energy 10 Home O This home meets or exceeds the criteria of the following: 2012 International Energy Conservation Code 2015 International Energy Conservation Code Rating Completed by: Energy Rater:Trevor Donnelly RESNETID:3461703 Rating Company:EnergyLogic PO Box N Berthoud, CO 80513 (970) 556-0839 Rating Provider EnergyLogic PO Box N Berthoud, CO 80513 �« (970) 556-0839 Trevor Donnelly, Certified Energy Rater IECC 2012 Performance Compliance Property DR Horton 2602 Palomino Ct Ft Collins, CO 80525 Template - DR Horton - 2482 FB Plat 2602 Palomino Ct DR Horton V2.1.0 Design Organization EnergyLogic Trevor Donnelly Inspection Status 7/31 /17 Builder Rater ID (RTIN): 3461703 DR Horton RESNET Confirmed Heating Cooling Water Heating SubTotal Used to determine compliance Lights & Appliances Onsite generation Total Annual Energy Cost IECC 2012 Performance S902 $135 $187 $1,223 $1,043 $0 $2,266 QnergyLogic OnatY Yl,, Inst96f, anay.�n. 405.3 40Z4,1.2 402.5 Performance -based compliance Air Leakage Testing Area -weighted average fenestration passes by 12.0% SHGC 402.5 403.2.2 404 Area -weighted average fenestration Duct Testing Lighting Equipment Efficiency U-Factor a Mandatory Checklist As Designed Design exceeds requirements for IECC 2012 Performance compliance by 12%. Name: Trevor Donnelly Organization: EnergyLogic Signature: �' 7 Date: Sep 15, 2017 Ekotrope HERS Rating Tool - Version 2.1.0,1769 IECC 2012 Performance compliance ras Lilts calculated using Ekolrape's energy algorithm, which is a RES NET Accredited IECC Rating Tool. $748 $141 $187 $1,076 $1,022 $0 $2,099 .:;ifrr°.r,.'47 •mi+•+idae;aaefri♦}�• tl y�yf••idi; a;ksdij*i'47x.•a�ttdei,is;°{dfii�'i:tf'•f+ad*''°}'t°jAs ,[Py ft ai •a,r.: x/ MA. ! .t r I ,. -is • r •e _ 4f rnf4 r ai'"t'Ait THIS HOME IS- 2012 INTERNATIONAL Ceiling Flat i i •' Above .•. Walls R-21 -.Foundation Framed 4' • ! ! Perimet 0.31 !! 4a _ �• organization below specifications, and other calculations IECC requirements in cor. +°Organization: a!_ a•a '!p The t s . �w t 'a,i" r _iffh of ..„ err. ^f •ir t��tf• 4` #�ii+e 4 �± '�r1 t s (�+trk f rs t ! ffe 4%' '�d �� •,� i�i! �Pa 1 t7 d�gy'aT y CERTIFIED TO. MEET"THE ENERGY CONSERVATION CODE ' Y F4 is 4• .. S• // . f•��ift ��tf•���4�4ifr1•�4sif!v��•}t�•r t•f}Qf •ts. {�f'..•t�rf•ef**i{f1;•1.0.f#MiSffi IECC 2012 Label 2602 Palomino Ct HERS9lndex Score: 57 Ceiling: R-38 Above Grade Walls: R-21 Foundation Walls: R-19 Exposed Floor: N/A Slab: R-0 Infiltration: 1530 CFM50 (1.8 ACH50) Duct Insulation: R-0 Duct Leakage: 0 CFM25 Window: U = 0.310, SHGC = 0.360 Door: R-6 Heating: Furnace • Natural Gas • 92.1 AFUE Cooling: Air Conditioner • Electric • 13 SEER Hot Water: Water Heater • Natural Gas • 0.59 Energy Factor 2005 EPAct Energy Efficient Home Tax Credit (13-001) Property Organization DR Horton EnergyLogic 2602 Palomino Ct Trevor Donnelly Inspection Status Ft Collins, CO 80525 7/31/17 Builder Rater ID (RTIN): 3461703 Template - DR Horton - 2482 FB Plat DR Horton RESNET Confirmed 2602 Palomino Ct DR Horton V2.1.0 RESNET Confirmed Rating. Normalized Modified End -Use Loads (MBtu / year) Category 2006 IECC 50% As Designed Target Heating 47.0 40.6 Cooling 3.9 5.1 Total 50.9 45.7 Ceiling U: 0.026 Wall U: 0.055 Framed Floor U: NaN Slab R: 0.0 Window U: 0.310 QnergyLogic ano�y J,. tn:lynl. a... �n. Envelope Loads (MBtu / year) Category 2006 IECC As Designed 90% Target Heating 84.6 52.7 Cooling 7.0 8.4 Total 91.6 61.1 Building Features Window Combined SHGC: 0.3 Heating System: AFUE = 92.1 % Cooling System: SEER = 13 Duct Leakage to Outside: 0.0 CFM25 This home meets the requirements for the residential energy efficiency tax credit under section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005. This tax credit has been extended through the year 2016. Name: Organization: Trevor Donnelly EnergyLogic Signature: YwPAY Date: Sep 15, 2017 Ekotrope HERS Rating Tool - Version 2.1.0.1769 This information does not constitute a warranty or guarantee of home energy performance. RESNET HOME ENERGY RATING Standard Disclosure QnergyLogic ne.r+i+. For home(s) located at: 2602 Palomino Ct , Ft Collins, CO Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page: 1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 02. In addition to the rating, the Rater of Rater's employer has also provided the following consulting services for this home: A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel L] E. Other(specify) 3. The Rater of the Rater's employee is: J A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home WJC. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home E]4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products HVAC systems Installed in this home by Rater Employer OR is in the business of Rater DEmployer Thermal insulation systems Rater Employer Rater DEmployer Air sealing of envelope or duct systems Rater Employer ORater Employer Energy efficient appliances Rater Employer Rater DEmployer Construction (builder, developer, construction contractor, etc) Rater Employer Rater Employer Other (specify): I- Rater DEmployer Rater Employer []5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 3461703 Name: Trevor Donnelly Organization: EnergyLogic Signature: ? v xy Date: Sep 15, 2017 I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at httpl-//resnet.us/standards/RESNET — Mortgage_ Ind ustry_Nationa I_HE RS_Standards.pdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 - Amended April 24, 2007 Air Leakage Report Property DR Horton 2602 Palomino Ct Ft Collins, CO 80525 Template - DR Horton - 2482 FB Plai 2602 Palomino Ct DR Horton V2.1.0 Organization EnergyLogic Trevor Donnelly Inspection Status 7/31 /17 Builder Rater ID (RTIN): 3461703 DR Horton RESNET Confirmed Air Leakaqe QnergyLogic anal Yflf. Insl9ftt. O vs� vef. Measurement Unit CFM at 50 Pa Measured Infiltration 1530 ACH50 (Calculated) 1.8 ELA [sq. in.] (Calculated) 84.2 CFM50 (Calculated) 1530 Duct Leakage Number of Duct Systems 1 System(s) Leakage to Outdoors [CFM @ 25 Pa] 0.0 Leakage to Outdoors [CFM25 / 100 s.f.) 0.0 Leakage to Outdoors [CFM25 / CFA] 0.000 Total Leakage Test Type Rough -In, with Air Handler Total Leakage [CFM @ 25 Pa] 111.0 Total Leakage [CFM25 / 100 s.f.] 2.2 Total Leakage [CFM25 / CFA] 0.022 Mechanical Ventilation Rate [CFM] 81.0 Hours per day 24.0 Fan Watts 15.0 Recovery Efficiency % 0.0 Runs at least once every 3 hrs? true Average Rate [CFM] 81.0 2010 ASHRAE 62.2 Req. Cont. Ventilation 80.9 Ekotrope HERS Rating Tool - Version 2.1.0.1769