HomeMy WebLinkAbout2602 Palomino Ct - Disclosures/Final Energy - 07/31/2017Home Energy Rating Certificate Rating Date: 7/31/17 (DnergyLogic
Registry ID: 273898405 ^^
Final Report Rating Number: 273898405
Your Home's Estimated Energy Use:
Use [MBtuj
Annual Cost
Heating
71.9
$537
Cooling
1.8
$53
Hot Water
18.7
$112
Lights/Appliances
32.5
$953
Service Charges
$240
Generation (e.g. Solar)
0.0
-$0
Total:
124.9
$1,894
Home Feature Summary:
r,a- rmM Eft'm
Home Type:
Single family detached
ao
Conditioned Floor Area:
5,091 sq. ft.
Homeg sao
Number of Bedrooms:
3
rw
m
Primary Heating System:
Furnace • Natural Gas • 92.1 AFUE
110
Reference WIF
100
Primary Cooling System:
Air Conditioner • Electric • 13 SEER
Home
Primary Water Heating:
Water Heater. Natural Gas • 059 Energy Factor
soso
House Tightness:
1530 CFM50 (1.8 ACH50)
�o
Duct Leakage to Outside:
0 CFM25
60
Above Grade Walls:
R-21
so
ao This Home
Ceiling:
R-38
w
Window Type:
U-Value: 0.310, SHGC: 0360
ae
Foundation Walls:
R-19
Zero Energy 10
Home O
This home meets or exceeds the
criteria of the following:
2012 International Energy Conservation Code
2015 International Energy Conservation Code
Rating Completed by:
Energy Rater:Trevor Donnelly
RESNETID:3461703
Rating Company:EnergyLogic
PO Box N Berthoud, CO 80513
(970) 556-0839
Rating Provider EnergyLogic
PO Box N Berthoud, CO 80513
�«
(970) 556-0839
Trevor Donnelly, Certified Energy Rater
IECC 2012 Performance Compliance
Property
DR Horton
2602 Palomino Ct
Ft Collins, CO 80525
Template - DR Horton - 2482 FB Plat
2602 Palomino Ct DR Horton V2.1.0
Design
Organization
EnergyLogic
Trevor Donnelly Inspection Status
7/31 /17
Builder Rater ID (RTIN): 3461703
DR Horton RESNET Confirmed
Heating
Cooling
Water Heating
SubTotal Used to determine compliance
Lights & Appliances
Onsite generation
Total
Annual Energy Cost
IECC 2012
Performance
S902
$135
$187
$1,223
$1,043
$0
$2,266
QnergyLogic
OnatY Yl,, Inst96f, anay.�n.
405.3 40Z4,1.2 402.5
Performance -based compliance Air Leakage Testing Area -weighted average fenestration
passes by 12.0% SHGC
402.5 403.2.2 404
Area -weighted average fenestration Duct Testing Lighting Equipment Efficiency
U-Factor
a
Mandatory Checklist
As Designed
Design exceeds requirements for IECC 2012 Performance compliance by 12%.
Name:
Trevor Donnelly
Organization: EnergyLogic
Signature: �' 7
Date: Sep 15, 2017
Ekotrope HERS Rating Tool - Version 2.1.0,1769
IECC 2012 Performance compliance ras Lilts calculated using Ekolrape's energy algorithm, which is a RES NET Accredited IECC Rating Tool.
$748
$141
$187
$1,076
$1,022
$0
$2,099
.:;ifrr°.r,.'47 •mi+•+idae;aaefri♦}�• tl y�yf••idi; a;ksdij*i'47x.•a�ttdei,is;°{dfii�'i:tf'•f+ad*''°}'t°jAs
,[Py ft ai •a,r.: x/ MA. ! .t r I
,. -is • r •e _ 4f rnf4 r ai'"t'Ait
THIS HOME IS-
2012 INTERNATIONAL
Ceiling Flat i i
•'
Above .•. Walls R-21
-.Foundation
Framed
4'
• ! ! Perimet
0.31
!!
4a _
�•
organization below
specifications, and other calculations
IECC requirements in cor.
+°Organization:
a!_
a•a
'!p
The t
s
.
�w
t
'a,i" r _iffh of ..„ err. ^f •ir
t��tf•
4`
#�ii+e 4 �± '�r1 t s (�+trk f rs t
! ffe 4%' '�d
�� •,� i�i!
�Pa 1 t7
d�gy'aT y
CERTIFIED TO. MEET"THE
ENERGY CONSERVATION CODE
' Y F4 is 4• .. S• // .
f•��ift ��tf•���4�4ifr1•�4sif!v��•}t�•r
t•f}Qf •ts. {�f'..•t�rf•ef**i{f1;•1.0.f#MiSffi
IECC 2012 Label
2602 Palomino Ct
HERS9lndex Score: 57
Ceiling: R-38
Above Grade Walls: R-21
Foundation Walls: R-19
Exposed Floor: N/A
Slab: R-0
Infiltration: 1530 CFM50 (1.8 ACH50)
Duct Insulation: R-0
Duct Leakage: 0 CFM25
Window: U = 0.310, SHGC = 0.360
Door: R-6
Heating: Furnace • Natural Gas • 92.1 AFUE
Cooling: Air Conditioner • Electric • 13 SEER
Hot Water: Water Heater • Natural Gas • 0.59
Energy Factor
2005 EPAct Energy Efficient Home Tax Credit (13-001)
Property Organization
DR Horton EnergyLogic
2602 Palomino Ct Trevor Donnelly Inspection Status
Ft Collins, CO 80525 7/31/17
Builder Rater ID (RTIN): 3461703
Template - DR Horton - 2482 FB Plat DR Horton RESNET Confirmed
2602 Palomino Ct DR Horton V2.1.0
RESNET Confirmed Rating.
Normalized Modified End -Use Loads (MBtu /
year)
Category 2006 IECC 50% As Designed
Target
Heating 47.0 40.6
Cooling 3.9 5.1
Total 50.9 45.7
Ceiling U:
0.026
Wall U:
0.055
Framed Floor U:
NaN
Slab R:
0.0
Window U:
0.310
QnergyLogic
ano�y J,. tn:lynl. a... �n.
Envelope Loads (MBtu / year)
Category 2006 IECC As Designed
90% Target
Heating 84.6 52.7
Cooling 7.0 8.4
Total 91.6 61.1
Building Features
Window Combined SHGC: 0.3
Heating System: AFUE = 92.1 %
Cooling System: SEER = 13
Duct Leakage to Outside: 0.0 CFM25
This home meets the requirements for the residential energy efficiency tax credit under section 1332, Credit for Construction of
New Energy Efficient Homes, of the Energy Policy Act of 2005. This tax credit has been extended through the year 2016.
Name:
Organization:
Trevor Donnelly
EnergyLogic
Signature: YwPAY
Date: Sep 15, 2017
Ekotrope HERS Rating Tool - Version 2.1.0.1769
This information does not constitute a warranty or guarantee of home energy performance.
RESNET HOME ENERGY
RATING Standard Disclosure QnergyLogic
ne.r+i+.
For home(s) located at: 2602 Palomino Ct , Ft Collins, CO
Check the applicable disclosure(s) in accordance with the
instructions on the reverse of this page:
1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home.
02. In addition to the rating, the Rater of Rater's employer has also provided the following consulting services for
this home:
A. Mechanical system design
B. Moisture control or indoor air quality consulting
C. Performance testing and/or commissioning other than required for the rating itself
D. Training for sales or construction personnel
L] E. Other(specify)
3. The Rater of the Rater's employee is:
J A. The seller of this home or their agent
B. The mortgagor for some portion of the financed payments on this home
WJC. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
E]4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products
HVAC systems
Installed in this home by
Rater Employer
OR is in the business of
Rater DEmployer
Thermal insulation systems
Rater
Employer
Rater
DEmployer
Air sealing of envelope or duct systems
Rater
Employer
ORater
Employer
Energy efficient appliances
Rater
Employer
Rater
DEmployer
Construction (builder, developer, construction contractor, etc)
Rater
Employer
Rater
Employer
Other (specify): I-
Rater
DEmployer
Rater
Employer
[]5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 3461703
Name: Trevor Donnelly
Organization: EnergyLogic
Signature: ? v xy
Date: Sep 15, 2017
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
httpl-//resnet.us/standards/RESNET — Mortgage_ Ind ustry_Nationa I_HE RS_Standards.pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 - Amended April 24, 2007
Air Leakage Report
Property
DR Horton
2602 Palomino Ct
Ft Collins, CO 80525
Template - DR Horton - 2482 FB Plai
2602 Palomino Ct DR Horton V2.1.0
Organization
EnergyLogic
Trevor Donnelly Inspection Status
7/31 /17
Builder Rater ID (RTIN): 3461703
DR Horton RESNET Confirmed
Air Leakaqe
QnergyLogic
anal Yflf. Insl9ftt. O vs� vef.
Measurement Unit
CFM at 50 Pa
Measured Infiltration
1530
ACH50 (Calculated)
1.8
ELA [sq. in.] (Calculated)
84.2
CFM50 (Calculated)
1530
Duct Leakage
Number of Duct Systems
1 System(s)
Leakage to Outdoors [CFM @ 25 Pa]
0.0
Leakage to Outdoors [CFM25 / 100 s.f.)
0.0
Leakage to Outdoors [CFM25 / CFA]
0.000
Total Leakage Test Type
Rough -In, with Air Handler
Total Leakage [CFM @ 25 Pa]
111.0
Total Leakage [CFM25 / 100 s.f.]
2.2
Total Leakage [CFM25 / CFA]
0.022
Mechanical Ventilation
Rate [CFM]
81.0
Hours per day
24.0
Fan Watts
15.0
Recovery Efficiency %
0.0
Runs at least once every 3 hrs?
true
Average Rate [CFM]
81.0
2010 ASHRAE 62.2 Req. Cont. Ventilation
80.9
Ekotrope HERS Rating Tool - Version 2.1.0.1769