Loading...
HomeMy WebLinkAbout2602 Palomino Ct - Disclosures/Blower Door Test - 07/31/2017 (2)(D nergyLogic analysis, insight, answers. www.nrglogic.com Date of Test: 7/31/2017 Customer: DR Horton Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level BUILDING LEAKAGE TEST 'bI(no Test File: Multi Point Tectite 2602 Technician: Trevor Donnelly- EnergyLogic Project Number: 47002 Building Address: 2602 Palomino Ct Fort Collins, CO 80524 1530 CFM50 (+/- 2.4 %) 1.83 ACH50 84.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 84.4 (+/- 41.1 %) Exponent (n) = 0.741 ( +/- 0.108 ) Correlation Coefficient = 0.98961 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: QnergyLogic www.nrglogic.com BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/31/2017 Test File: Multi Point Tectite 2602 Building Information Volume 50152 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction 2016 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 7170-5 10/9/2008 QnergyLogic www.nrglogic.com BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/31/2017 Test File: Multi Point Tectite 2602 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 85.0 95.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -6.5 n/a n/a -65.8 -59.5 77.3 -63.7 -57.4 73.6 -58.4 -52.1 64.6 -54.5 -48.1 59.4 -49.2 -42.9 48.7 -46.6 -40.2 43.7 -42.4 -36.1 40.0 -39.6 -33.2 30.0 -6.2 n/a n/a Time Averaging Period: 0 Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1584 1721 -1.1 Ring A 1546 1680 -0.8 Ring A 1451 1576 -0.1 Ring A 1393 1513 1.7 Ring A 1264 1374 0.6 Ring A 1199 1303 0.0 Ring A 1149 1248 3.8 Ring A 998 1084 -4.1 Ring A Deviations from Standard RESNET Multi -Point Test - Test Parameters None correlation coefficient outside of normally accepted limits. n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. QnergyLogic www.nzq�ogic.com BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/31/2017 Test File: Multi Point Tectite 2602 Comments Connection to: Garage: -50 Pa Mechanicals: -50 Pa