HomeMy WebLinkAbout227 Osiander St - Disclosures/Blower Door Test - 09/06/2017(Dn e r g y L o g 1 C BUILDING LEAKAGE TEST 1 an a I ys Is. Ins I ht. answers. Date of Test: 9/6/2017 Test File: 227 Multi Point Tectite Customer: Erik Haagenson Technician: Neal Girard - EnergyLogic, Inc. Project Number: 48414 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building -Leakage Curve: 4. Test Settings: 5. Accuracy Level Building Address: 227 Osiander St. Ft. Collins, CO 80524 651 CFM50 (+/- 0.8 %) 1.44 ACH50 35.8 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 22.0 (+/- 13.4 %) Exponent (n) = 0.866 ( +/- 0.035 ) Correlation Coefficient = 0.99918 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 38.0 CFM 0.08 ACH 9.5 CFM per person Winter: 71.4 CFM Summer: 44.8 CFM 0.16 ACH 0.10 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 58.0 CFM Base Rate: 58.0 CFM QnergyLogic BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/6/2017 Test File: 227 Multi Point Tectite Building Information Volume 27066 Surface Area Floor Area 2796 Height 20 # of Bedrooms 3 # of Occupants 4 Year of Construction 2017 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 36002-7 11/15/2012 QneFgyLogic _�r:..:.. ....... ,.._.,. - BUILDING LEAKAGE TEST Page 3 of 4 Date of Test:9/6/2017 Test File: 227 Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature(°F) Outdoor Temperature(°F)' Altitude(ft) 70.0 90.0 5000A � Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) %Error Configuration -1 0.0 n/a n/a -70.0 -59.5 127.1 669 756 -0.0 Ring B -65.6 -55.1 113.2 632 714 0.9 Ring B -62.0 -51.5 98.3 589 666 -0.3 Ring B -57.7 -47.2 84.3 546 617 -0.4 Ring B -54.3 -43.8 74.4 513 580 -0.0 Ring B -49.7 -39.2 61.2 466 527 -0.2 Ring B -45.9 -35.4 50.2 422 478 -1.2 Ring B -42.8 -32.3 44.8 399 451 1.3 Ring B -11.0 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test-Test Parameters None QnergyLogic ...�..:.. ........ ..... � BUILDING LEAKAGE TEST Page 4 of 4 � �=� ,. Date of Test: 9/6/2017 Test File:227 Multi Point Tectite Comments Connection to: Garage: NA Mechanicals: NA � . 1 �