HomeMy WebLinkAbout2436 Cochetopa Ct - Special Inspections/Combustion Safety - 11/14/2016Appendix D, Combustion Furnace Commissioning Form calm fIC1811CyVNOC1GS- Customer Na a rint): I Lrn Signature: Address 2 Permit # Exclusion. The customer hereby unperstands that the combustion process and evaluation o performance of any existing water heateris not addressed by this commissioning evaluation procedure under EW-H. Company Performing Comm issi ni F Colli s Heating and Air Conditioning Technician (signature): (Print Name): Alex Murphy Manual J Loads - Heating: Btuh %% -�C_�o�o-�li'n�,,gg(�ensible): Btuh Age/Type of Structure: t Yn Z Sktil Location of Furnace: Accessible return ducts sealed?: L37 Manufacturer: Model: Is the Furnace multi -stage?:- ECM or other DC Blower Motor used-: E Lill/1 Are Furnace Vents Sized, Supported, and Terminated !1-14- 1A!JjiQ j0V1-1 Size: Btuh Does the Furnace have a communicating thermostat?: OEM instructions and International Residential Code?: Rated Gas Pressure (IWC) -Low: 1.4 High._ Measured Gas Pressure (IWC) - Low-2SHigh 1.1 Is the Manifold gas pressure within the'OEM spsclfled range it each stage?: Supply Air ESP @ High Heat fan speed (IWC):-, I'l Return Air ESP @ High Heat fan speed (IWC): Factory Rated Maximum TESP (IWC): . S Measured TESP @ High Heat fan speed (IWC): ,, t(7 Low Heat fan speed High Heat fanspeed Nameplate Rated Temp Rise ('F): 30 - W 0 `7o Measured Temp Rise ('F):l 46 59 Blower Amps s At steady state, is Temperature. Rise within OEM temperature range.at each fan speed?._jjr.S . r'srvewwe..r,w.�. Furnace flue gas CO readings (ppm) ow Heat S High Heat: 2 Is CO within accepted range at high fire?: Combustion Efficiency: % Method or Equipment Used 7PI 1 ft Method used to measure Indicated air flow: OW Manometer used 7 00 (DG, DM, Magnehelic, or other?) With DG-2, DM-2, or other pressure gauges, convert pressure to Indicated air flow per TrueFLow Appendix A. Indicated air flow - Low Heat fan speed (CFM):�_ High Heat fan speed (CFM): i X0. Convert Indicated air flow to Volumetric air flow using TrueFlow Appendix C, Table C.t.c . Volumetric air flow - Low Heat fan speed (CFM): 1673 High Heat fan speed (CFM): I3RL �d Natural draft gas appliance flue gas spillage time @ worst case?: sec. Pass test?: Yes No ❑ Natural draft gas appliance flue gas spillage time @ natural conditions?: sec. Pass test?: Yes I;( No ❑ Water Heater orphaned?:d Existing B-vent size?: 5 Has the B-vent been re -lined?: A 0 CO level at steady state in Natural Draft Appliance undiluted flue gases (ppm): /,- Ambient CO (ppm): Company Name Fort Collins Heating and Air Conditioning Technician Signature Date �b