Loading...
HomeMy WebLinkAbout1754 Yucca Ct - Special Inspections/Engineering - 07/28/2017ADVANCED ENGINEERING, LLC STRUCTURAL DRAINAGE DRAFTING July 28, 2017 State Law Requires a 319 Carbon Monoxide Alarm B 17 0 4 ' G2 Construction, LLC Within 15 feet of each 5805 Mangrove Court bedroom entrance. Loveland, Colorado 80538 ALL ELECTRICAL WORK RE: 1754 Yucca Court, Fort Collins, Colorado SHALL BE IN COMPLIANCE Advanced Engineering, LLC Project Number 2445-09-01 A WITH THE CURRENT N.E.C. Dear Mr. Griess: On July 20, 2017 we visually observed portions of the above referenced residence. The purpose for this observation was to provide structural consulting related to the modification of an existing basement window. The window at the northwest basement bedroom, in the north concrete foundation wall, is to be increased in depth to accommodate egress requirements. You stated that the existing foundation and framing elements above the window opening will not be removed or altered in any way, and the width of the window will remain unchanged from existing conditions. The concrete wall below the existing window is to be neatly cut to the new window depth. We noted that the existing concrete wall has performed well to date in the visible area below the window (where paneling had been removed). It is our opinion the proposed window modification is acceptable and no structural repairs are required. We feel the existing structure above the window should continue to function well, as it has historically. While we would not anticipate any significant problems, you should be made aware that some minor cracking of the concrete may occur at the bottom corners of the window opening due to the absence of trim steel. However, due to the minimal reinforcing in foundation walls of this age, cracking of this nature is possible at any of the basement windows. The recommendations and conclusions presented in this letter are based solely on a visual review of portions of the described structure and your directions. The engineer's opinions of the described portions of the home are based solely)upgnlinfotmatiotlobfain'e"drfrorn' ,readily visible elements (i.e., elements which do not require the removal of sheathing, cladding, or covering of any kind) unless specifically noted. Latent structural :problems which could not be d"eted168lla6s a result of these limitations may exist. Our review was limited to the items described in this letter, and is not intended to cover other structural, meci anical,:electncal; enviroruneiital, mold, site grading, or architectural features of the building. Our office has not performednany, englineering analysis of the oil existing framing or foundation -elements of the structure-or'the subsurface soil conditions. Thank you for the opportunity to servWoF!fiee feel free to call if yputhave�anytquestions. Sincerely Z pN E00 • Bq ••�� /� Advanced Engineerin _ .r? �t�`•.��►�"'— �ssa�ti� P `'s#tl`''t3c`� 3 :o _ SMOKE & CO ALARMS • ARE R,FC VIRP PER - w, CURRENT IRC / IBC Jason E. Baker, P.E. ��''/'SS/ANAL EaG� ��RX\\ 229 12'" Street SM�(!8QVt91h`d Colorado 80537 Telephone 970-278-1909