Loading...
HomeMy WebLinkAbout227 Osiander St - Special Inspections/Engineering - 04/13/2017CSE Consultants 1212 Riverside Avenue 'Ms Brianne Haagenson `" Ft Collins, CO80524 245 Osiandei St _ ' Ph (970) 282/8005 Fort Collins, CO e-mail dicse@gwestoffice net - - Re 227 (Islander 3 47 Fort Collins, Colorado CSE Project No C9154-1 ,Deal Ms Haagenson CSE Consultants visited the above -referenced project on April 10, 2017 as requested The purpose of this visit was To observe the following five items 1 A 91/'2" deep second floor ljolst spanning east -west located approximately 14V2 feet south of the front, door has the north face of the I joist top chord cut out for electrical wiring at a location of approximately at 3'-6" to 4'-0" east of the centerlme of the W 1 Ox?2 steel second floor beans Refer to "Item I Reinforcing" per the attached sheet SX I for repair plans _ 2 A91/2" deep second floot 1-joist spanning east -west located approxuliatcly 13 feet south of the front door has the ,-syeb cut out for a flexible mechanical duct at a distance of approximately T-31," west of the eenterline_of the N7V1 Ox22 steel second floor beam The web cut for the mechanical duct is closer to the end.of the joist than permitted u) the manufacturer user guide - - Refer to "Item 2 Rennforcmg" per the attached sheet Sal forrepan plans 3 A double 11 7/8" deep second floor I ;joist spanning north -south above the garage located appioannately 4 feet east of the garage exterior west wall has the webs cut out for a flexible mechanical duct at a distance of approximately 4'-0" from the north end of the joist The web out for the mechanical duct is closer to the end of the joist than peumtted in the manufacturer user guide This double joist was specified to be a (2) 1 3/4 x 11 7,18 LVL beans on the plans - The joists used (PW147) exceed the properties of the floor Joists specified The double joists used In lieu of the double LVL specified and tlus'web hole ns deemed acceptable„ _ 4 The 11 7/8" deep second floor 1-joists spanning north -south above the garage that are parallel with and adjacent to the (3) 1 3/4 x 11 7/8 LVL flush joist in the second floor system are not located 1'-0" east and 1'-0" west of the Lb L flush joist as indicated on the plans The west joist centerline is located 1'-7" west of the LVL center line and the east joist centerline is located 12 3/4" east of the LVL centerline. - This item is deemed acceptable 5 The basement level steel columns are incorrect (C1 and C2 columns installed as incorrectly switched) - install the correct C 1 and C2 columns at the locations indicated on the plans , 4 Sniceiely, �N, �q DREG/sj CSE Consultants ((��`•"" / Ron L `Lindbutg, P E (1)`LAYER OF 15/32" OSB SHEATHING = (2) LAYERS OF 15/32" OSB SHEATHING EACH SIDE OF JOIST FROM TIGHT EACH SIDE OF JOIST WEB' SCREW EACH SIDE w/ ROW OF TWO r TOP OF TOP FLANGE TO THE ' #8 x 2' DECK SCREWS 2" FROM THE BOTTOM OF BOTTOM FLANGE., TAND BOTTOM OF REINFORCING SCREW EACH SIDE w/ ROW OF TWO ? ;_ A" SPACING. _ #8 x 2' DECK SCREWS CENTERED ti `AT,JOIST FLANGES AT 3" SPACING ` s< (1) LAYER OF 15/32 OSB SHEATHING TOP �x EACH SIDE OF JOISUROM _ BOTTOM OF TOP FLANGE TO THE 'BOTTOM OF BOTTOM FLANGE. ITEM 1 REINFORCING SCREW EACH SIDE w/ ROW OF TWO 8 x 3 DECK SCREWS 2 ITEM 2 REINFORCING FROM THE TOP AND CENTERED AT BOTTOM FLANGE AT 8" SPACING. STAGGER FROM /3• 17 THE INNER REINFORCING PATTERN. REINFORCE 4'-0 LENGTH ' EACH SIDE PER ITEM 1 ABOVE REINFORCE 8 LENGTH _ EACH SIDE r PER ITEM 2 ABOVE 4'-0" 2'`3� ( HOLE T( DAMAGED TOP CHORD EXISTING 2nd FLOOR TO BEAT (ITEM 1) JOISTS SHEATHING . (ITEM 2; 9 / V744 4 ' - < 4 EXISTING W10x22 2nd FLOOR BEAM 0 CLOSE ING r VIEWING SOUTH NOTE: ITEM 1 ITEM 2 SX>i jk �' = 1-0" ARE NOT AT SAME JOIST 'l CSE Consu tants _ = ` �;, A 1212 Riverside Avenue p": •���� Fort Collins, CO 80524o,•...• ' t�C', Ph 970-282-8005 e-mail rllcseQgwestoffice net _ A;q; 10` CSE Protect No C9154-1 HAAGEN5ON RESIDENCE 227 OSIANDER STREET APRIL 11, 2017 -SHEET SM 1of 1 3 .,