HomeMy WebLinkAbout369 Pilsner St - Disclosures/Blower Door Test - 08/03/2017.did x[G fii LL r.■ I c B1700923 i ` 'I 2 ', BUILDING LEAKAGE TEST GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 8/3/2017 Test File: FR Development - 369 Pilsner St - BD1 Customer: FR Development Technician: Nick Hiseler Project Number: Building Address: 369 Pilsner St Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 708 CFM50 (+/- 3.1 %) (50 Pa = 0.2 w.c.) 2.02 ACH50 2. Leakage Area: 38.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 46.1 (+/- 22.3 %) Exponent (n) = 0.698 ( +/- 0.062 ) Correlation Coefficient = 0.99611 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Matt Matt DINISdiCN t iN' =Matt Schubert email aa, mdschuberll @hotmail.com S c h u b ertto to 0117.08.04 11:44 39 - �07'00' B170 ' 4- 6S e ' es F BUILDING LEAKAGE TEST Page 2 of % 0,1 j (; sl U , 1 U U *.-7 Date of Test: 8/3/2017 Test File: FR Development - 369 Pilsner St - BD1 Building Information Volume 21054 Surface Area Floor Area 1823 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 19028 9/9/2014 17n r Se R 09 2 ._.�eS BUILDING LEAKAGE TEST Pager3 of 4 Date of Test: 8/3/2017 Test File: FIR Development - 369 Pilsner St - BD1 Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 71.0 1 64.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -1.4 n/a n/a -61.3 -60.0 183.1 -55.5 -54.3 158.9 -48.4 -47.2 123.9 -43.1 -41.8 95.2 -37.1 -35.9 85.8 -31.9 -30.7 66.3 -25.9 -24.7 48.9 -19.2 -17.9 33.7 -1.0 n/a n/a Time Averaging Period: 0 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 802 822 2.2 Ring B 748 767 2.3 Ring B 661 678 -0.3 Ring B 580 595 -4.9 Ring B 551 565 0.6 Ring B 485 497 -1.2 Ring B 417 428 -1.2 Ring B 347 355 2.7 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters ram,, - 100993 BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/3/2017 Test File: FIR Development - 369 Pilsner St - BD1 Comments Detached Garage