HomeMy WebLinkAbout369 Pilsner St - Disclosures/Blower Door Test - 08/03/2017.did x[G fii LL
r.■ I
c
B1700923
i ` 'I 2 ', BUILDING LEAKAGE TEST
GS Services, LTD.
2000 S College Ave #308
Fort Collins, CO 80525
Email: buildingperformance@gsservices.com Website: gsservices.com
Date of Test: 8/3/2017 Test File: FR Development - 369 Pilsner St - BD1
Customer: FR Development Technician: Nick Hiseler
Project Number:
Building Address: 369 Pilsner St
Fort Collins, CO
Test Results
1. Airflow at 50 Pascals: 708 CFM50 (+/- 3.1 %)
(50 Pa = 0.2 w.c.) 2.02 ACH50
2. Leakage Area: 38.9 in2 LBL ELA @ 4 Pa
3. Building Leakage Curve: Flow Coefficient (C) = 46.1 (+/- 22.3 %)
Exponent (n) = 0.698 ( +/- 0.062 )
Correlation Coefficient = 0.99611
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Digitally signed by: Matt
Matt DINISdiCN t
iN' =Matt Schubert email
aa, mdschuberll @hotmail.com
S c h u b ertto to 0117.08.04 11:44 39 -
�07'00'
B170 ' 4-
6S e ' es F
BUILDING LEAKAGE TEST Page 2 of % 0,1
j (; sl
U , 1 U U *.-7
Date of Test: 8/3/2017 Test File: FR Development - 369 Pilsner St - BD1
Building Information
Volume
21054
Surface Area
Floor Area
1823
Height
# of Bedrooms
# of Occupants
Year of Construction
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel
Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
19247
Default
Micromanometer
Energy Conservatory
DG700
19028
9/9/2014
17n r
Se R 09 2
._.�eS BUILDING LEAKAGE TEST Pager3 of 4
Date of Test: 8/3/2017 Test File: FIR Development - 369 Pilsner St - BD1
Depressurization Test:
Environmental Data
Indoor Temperature (A°F)
Outdoor Temperature (A°F)
Altitude (ft)
71.0
1 64.0
5000.0
Data Points
Nominal Baseline Adjusted Fan
Building Pressure Building Pressure Pressure
(Pa) (Pa) (Pa)
-1.4
n/a
n/a
-61.3
-60.0
183.1
-55.5
-54.3
158.9
-48.4
-47.2
123.9
-43.1
-41.8
95.2
-37.1
-35.9
85.8
-31.9
-30.7
66.3
-25.9
-24.7
48.9
-19.2
-17.9
33.7
-1.0
n/a
n/a
Time Averaging Period: 0
None
Nominal Adjusted
Flow Flow Fan
(cfm) (cfm) % Error Configuration
802
822
2.2
Ring B
748
767
2.3
Ring B
661
678
-0.3
Ring B
580
595
-4.9
Ring B
551
565
0.6
Ring B
485
497
-1.2
Ring B
417
428
-1.2
Ring B
347
355
2.7
Ring B
Deviations from Standard RESNET Multi -Point Test - Test Parameters
ram,, -
100993
BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 8/3/2017 Test File: FIR Development - 369 Pilsner St - BD1
Comments
Detached Garage