Loading...
HomeMy WebLinkAbout2801 Cherrystone Pl - Special Inspections/Engineering - 06/16/2017w .00•. ❖•�. IN 01 - June 16, 2017 Mr Scott Freestone Freestone Design Build 7889 Kremers Lane Laporte, CO 80535 RE 2801 Cherrystone Place, Ft. Collins, Colorado Advanced Engineering, LLC Project Number 2667-04-01A Dear Mr. Freestone• R1?03339 We have visually observed portions of the above referenced residence on April 14, 2017. The purpose for this observation was to provide structural consulting related to a proposed interior remodel project. We observed portions of the interior and exterior of the home, including portions of the exposed framing at the attic, basement and crawl space The following is our observations, opinions and recommendations You have provided a proposed floor plan, which indicates the interior partition walls between the sun room, family room and dining room are to be removed These walls are bearing for the roof trusses above, you provided a layout of the trusses New beams will be installed in place of the removed wall lines to support the trusses. Attached is a copy of your floor plan with our recommendations for framing to support the roof at these areas. Our recommendations are based on a 30 psf Roof Live Load and a 15 psf Roof Dead Load. The new beams will bear over the existing foundation elements, however verification of bearing at the south stair wall will be needed at the time of construction (a new footing may be needed in the basement) The recommendations and conclusions presented in this letter and the attached sheet are based on a visual review of portions of the described structure, information you provided and your directions The engineer's opinions of the described portions of the home are based solely upon information obtained from readily visible elements (i.e , elements which do not require the removal of sheathing, cladding, or covering of any kind) unless specifically noted Our review was limited to the items described in this letter, and is not intended to cover other structural, mechanical, electrical, environmental, mold, site grading, or architectural features of the building Any discrepancies or structural deficiencies revealed during construction should be brought to the attention of the engineer. If you have any questions, plea.§g,feel free to call. .�p0 RE G S you Sincerely, a����`pQ"P'pN E •eqIr ��'AR Advanced Engineering, LL r,� .•' 3739 Jason E. Baker, P E.%,0,.�'f:.;��0•:�•?G��',.� President 229 12' Street SW, Loveland, Colorado 80537 Telephone 970-278-1909